Thursday, June 29, 2017

Hbuster HBTV 42L07FD – SMPS schematic

Used ICs: SCC9502S, L6562D, STRA6059H
Click on the pictures to magnify

Wednesday, June 28, 2017

Toshiba 22AV733G LCD TV – internet setting – Audio amplifier schematic - power board circuit diagram – using with network

MAIN BOARD - 715G3747-D
POWER BOARD - 715G3721
Internet Explorer Settings
When Windows XP SP2 or Windows Vista is used, ActiveX control and pop-up windows are limited by the enhanced security function and this system may not work. In that case, perform the Internet Explorer setting using the following procedure to restore normal operation
Windows version check
1. [My Computer (right-click)] - [Properties]
2. Internet Explorer setting - [Tools] - [Internet Options]
Using with Network
Precaution: To use ZEUS Service Manual Ver.2 with network, the file-path names written on the source files of each ZEUS Engine Program Ver.2 and ZEUS Service Manual Ver.2 are to be modified.
Perform the procedure described below.
Preparation
1. Run the program file zuesFPch.exe to install the program file for File-Path to the Local PC.  -> Download zeusFPch_setup.zip (2.3MB)
2. Run the program file ZeusSetup_v2.0.exe to install the ZEUS Engine Program in C:\Program Files\zeus of the local PC. This can be done by running the installer program provided.
3. Create the appropriate folder where the ZEUS Engine Program Ver.2 and the ZEUS Service Manual Ver.2 to be stored in the server.
4. Move the ZEUS Engine Program of step 2 to the folder created at step 3 in the Server.
5. Detach the ZEUS Service Manual Ver.2 to the folder created at step 3 in the Server.
6. Unzip the ZEUS Service Manual Ver.2 within the folder in the Server. 
Example of folder:
Procedure of File-Path
The zeusFPch is the exclusive program to exchange the file-path names written in both source files of ZEUS Manual and ZEUS Engine program into those applicable to the network use.
Whenever changing the file-path of both ZEUS Engine Program and ZEUS Service Manual to use with network, pay the attention to set the "Exchange to" column that should have a proper relation between ZEUS Engine Program and ZEUS Service Manual with referring the following.
1. Run the zeusFPch and set "Exchange to" by referring to the examples below.
Example 1 :
In the "Exchange to" column shows the relation between ZEUS Service Manual and ZEUS Engine Program.
../ counts the relation between.
Thus in this case, it must be ../../zeus/ (2 counts).
Example 2 :
In this case, it must be ../../../zeus/ (3 counts).
2. Run the zeusFPch to change the path in the ZEUS Engine Program Ver.2.
3. Set ZEUS Engine Program in the created folder in the server to the "Target Folder", and then press "START"
(This procedure is one time only)
4. Run the ZeusFPch to change the path in the ZEUS Service Manual Ver2.
5. Set unzipped ZEUS Service Manual in the created folder in the server to the "Target Folder", and then press "START".  (This procedure is required whenever placing service manual.)
Confirmation
Confirm that service manual on the server can be operated normally by client PC.
Note:  In case of accessing the ZEUS Manual through WEB site, the small pop-up window appears at the left bottom corner on the screen whenever searching the location links. This is not malfunction.
A Known Malfunction
Autodesk® DWF™ Viewer version  (Free software provided through WEB)
Use Autodesk DWF Viewer ver. 6.0.
Through WEB, ver. 6.5 has been released but with it, the linking function in this manual may not work properly.
If ver. 6.5 has been installed, uninstall it and reinstall ver. 6.0.
To get ver. 6.0, click the icon, or contact to the nearest Toshiba Service Centre for further assistance.
Freezing windows opened  (Cannot close the open windows)
This may happen occasionally.  In case of encountering this, follow the procedure below.
1. Press [Ctrl], [Alt] and [Delete] keys at the same time to engage windows security windows.
2. Then, choose TASK manager and Application tab, and select TOSHIBA SERVICE MANUAL-Microsoft Internet Explorer.
3. Click TASK-end.
Main Window back forwarded
The real cause has not been found yet but with this condition, nothing disturbs the service manual operation.  Continue to use by operating the windows.
Precaution when opening the diagrams
While opening the diagrams, the menu in the left frame changes its color to GRAY. This is an indication that the viewer is processing.
With this condition, the menu indication color may stick to the GRAY color or Windows may freeze if clicking other menu.
To avoid such things, do not operate any others while menu turns GRAY color.
If entering this, re-open the service manual or refresh the left frame.

Audio amplifier schematic
[In the event that the screen is damaged or the liquid crystal (fluid) leaks, do not breathe in or drink this fluid.  Also, never touch this fluid. Such actions could cause toxicity or skin irritation. If this fluid should enter the mouth, rinse the mouth thoroughly with water. If the fluid should contact the skin or clothing, wipe off with alcohol, etc., and rinse thoroughly with water. If the fluid should enter the eyes, immediately rinse the eyes thoroughly with running water]
                                                           To see the SMPS circuit diagram, visit the previous post here

715G3721-P01-H20 - LCD power supply schematic - Toshiba 22AV733G LCD TV

Used semiconductors: LD7575A-PS, 2SK4101LS(FET), OZ9938GN, AO4616
Back-light inverter section circuit
Main SMPS section circuit
Click on the schematics to magnify

Tuesday, June 27, 2017

Philips 40PFG5100-77 LED LCD Service Modes, Error Codes, and Fault Finding - Chassis TPM15.4L

Philips 32PFG5100, Philips 40PFG5100 and Philips 48PFG5100 LED LCD TVs- how to enter service mode, adjustments, software update and more...
Service Modes
The Service Mode feature is split into five parts:
* Service Alignment Mode (SAM).
* Factory Mode.
* Customer Service Mode (CSM).
* Computer Aided Repair Mode (ComPair).
SAM and the Factory mode offer features, which can be used by the Service engineer to repair/align a TV set. Some features are:
* Make alignments (e.g. White Tone), reset the error buffer (SAM and Factory Mode).
* Display information (“SAM” indication in upper right corner of screen, error buffer, software version, operating hours, options and option codes, sub menus).
The CSM is a Service Mode that can be enabled by the consumer. The CSM displays diagnosis information, which the customer can forward to the dealer or call centre. In CSM mode, “CSM”, is displayed in the top right corner of the screen.
The information provided in CSM and the purpose of CSM is to:
* Increase the home repair hit rate.
* Decrease the number of nuisance calls.
* Solved customers’ problem without home visit.
ComPair Mode is used for communication between a computer and a TV on I2C /UART level and can be used by a Service engineer to quickly diagnose the TV set by reading out error codes, read and write in NVMs, communicate with ICs and the micro processor (PWM, registers, etc.), and by making use of a fault finding database. It will also be possible to up and download the software of the TV set via I2C with help of ComPair. To do this, ComPair has to be connected to the TV set via the ComPair connector, which will be accessible through the rear of the set (without removing the rear cover).
Note: For the new model range, a new remote control (RC) is used with some renamed buttons. This has an impact on the activation of the Service modes. For instance the old “MENU” button is now called “HOME” (or is indicated by a “house” icon)
Life Timer
During the life time cycle of the TV set, a timer is kept (called “Op. Hour”). It counts the normal operation hours (not the Stand-by hours). The actual value of the timer is displayed in SAM in a decimal value. Every two soft-resets increase the hour by + 1. Stand-by hours are not counted.
Software Identification, Version, and Cluster
The software ID, version, and cluster will be shown in the main menu display of SAM and CSM.
The screen will show: “AAAAAAB-XXX.YYY.MMM.TTT”,
where:
* AAAAAA is the chassis name: TPM142L.
* B is the region indication: E = Europe, A = AP/China, U = NAFTA, L = LATAM.
* XXX is the main version number: this is updated with a major change of specification (incompatible with the previous software version). Numbering will go from 0- 255.
* YYY is the sub version number: this is updated with a minor change of specification (incompatible with the previous versions). Numbering will go from 0- 255.
* MMM is the number of the mandatory (upgrade) release in association with the area of the mandatory (upgrade) release. Numbering will go from 0 - 255.
* TTT bit 7 to 1 is the area of the mandatory (upgrade) release where 0 - none, 1 - Netflix, rest reserved.
* TTT bit 0 : 0 = development release, 1 = production release.
Display Option Code Selection
When after an SSB or display exchange, the display option code is not set properly, it will result in a TV with “no display”.  Therefore, it is required to set this display option code after such a repair.
To do so, press the following key sequence on a standard RC transmitter: “062598” directly followed by MENU and “xxx”, where “xxx” is a 3 digit decimal value of the panel type. When the value is accepted and stored in NVM, the set will switch to Stand-by, to indicate that the process has been completed.  During this algorithm, the NVM-content must be filtered, because several items in the NVM are TV-related and not SSB related (e.g. Model and Prod. S/N). Therefore, “Model” and “Prod. S/N” data is changed into “See Type Plate”. In case a call center or consumer reads “See Type Plate” in CSM mode.
Service Alignment Mode (SAM)
> To modify the NVM.
> To display/clear the error code buffer.
> To perform alignments.
Specifications
* Operation hours counter (maximum five digits displayed).
* Software version, error codes, and option settings display.
* Error buffer clearing.
* Option settings.*
* Software alignments (White Tone).
* NVM Editor.
* Set screen mode to full screen (all content is visible).
How to Activate SAM
To activate SAM, use one of the following methods:
> Press the following key sequence on the remote control transmitter: “062596”, directly followed by the “INFO/OK” button. Do not allow the display to time out between entries while keying the sequence.
> Or via ComPair.
After entering SAM, the following items are displayed, with “SAM” in the upper right corner of the screen to indicate that the television is in Service Alignment Mode.
How to Navigate
> In the SAM menu, select menu items with the UP/DOWN keys on the remote control transmitter. The selected item will be indicated. When not all menu items fit on the screen, use the UP/DOWN keys to display the next/previous menu items.
> With the “LEFT/RIGHT” keys, it is possible to:
* (De) activate the selected menu item.
* (De) activate the selected sub menu.
> Change the value of the selected menu item.
* When you press the MENU button once while in top level SAM, the set will switch to the normal user menu (with the SAM mode still active in the background).
How to Store SAM Settings
To store the settings changed in SAM mode (except the RGB Align settings), leave the top level SAM menu by using the POWER button on the remote control transmitter or the television set. The mentioned exceptions must be stored separately via the STORE button.
How to Exit SAM
Use one of the following methods:
> Switch the set to STANDBY by pressing the mains button on the remote control transmitter or the television set.
> Via a standard RC-transmitter, key in “00” sequence.
Note: When the TV is switched “off” by a power interrupt while in SAM, the TV will show up in “normal operation mode” as soon as the power is supplied again. The error buffer will not be cleared.
Contents of the Factory mode
Purpose
> To perform extended alignments.
Specifications
* Displaying and or changing Panel ID information.
* Displaying and or changing Tuner ID information.
* Error buffer clearing.
* Various software alignment settings.
* Test pattern displaying.
* Public Broadcasting Service password Reset.
* etc.
How to Activate the Factory mode
To activate the Factory mode, use the following method:
> Press the following key sequence on the remote control transmitter: from the “menu/home” press “1999”, directly followed by the Back/Return” button. Do not allow the display to time out between entries while keying the sequence.
After entering the Factory mode, the items are displayed.
How to Exit the Factory mode
Use one of the following methods:
> Select EXIT_FACTORY from the menu and press the “OK” button.
Note: When the TV is switched “off” by a power interrupt, or normal switch to “stand-by” while in the factory mode, the TV will show up in “normal operation mode” as soon as the power is supplied again. The error buffer will not be cleared.
Customer Service Mode (CSM)
Purpose
The Customer Service Mode shows error codes and information on the TVs operation settings. The call center can instruct the customer (by telephone) to enter CSM in order to identify the status of the set. This helps the call center to diagnose problems and failures in the TV set before making a service call.
The CSM is a read-only mode; therefore, modifications are not possible in this mode.
Specifications
* Ignore “Service unfriendly modes”.
* Line number for every line (to make CSM language independent).
* Set the screen mode to full screen (all contents on screen is visible).
* After leaving the Customer Service Mode, the original settings are restored.
* Possibility to use “CH+” or “CH-” for channel surfing, or enter the specific channel number on the RC.
How to Activate CSM
To activate CSM, press the following key sequence on a standard remote control transmitter: “123654” (do not allow the display to time out between entries while keying the sequence).  After entering the Customer Service Mode, the following items are displayed.
Note: Activation of the CSM is only possible if there is no (user) menu on the screen.
Contents of CSM
1 Set Type This information is very helpful for a help-desk/workshop as reference for further diagnosis. In this way, it is not necessary for the customer to look at the rear of the TV-set. Note that if an NVM is replaced or is initialized after corruption, this set type has to be re-written to NVM.
2 Production code Displays the production code (the serial number) of the TV. Note that if an NVM is replaced or is initialized after corruption, this production code has to be re-written to NVM.
3 Installation date Indicates the date of the first installation of the TV. This date is acquired via time extraction.
4 a Option Code 1 Gives the option codes of option group 1 as set in SAM.
4b Option Code 2 Gives the option codes of option group 2 as set in SAM.
5 SSB Gives an identification of the SSB as stored in NVM. Note that if an NVM is replaced or is initialized after corruption, this identification number has to be re-written to NVM. This identification number is the 12NC number of the SSB.
6 Display 12NC NVM read/write.
7 PSU 12NC NVM read/write.
8 RF4CE 12NC NVM read/write.
2.1 Current Main SW Displays the built-in main software version. In case of field problems related to software, software can be upgraded. As this software is consumer upgradeable, it will also be published on the internet.
2.2 Standby SW Displays the built-in stand-by processor software version. Upgrading this software will be possible via USB.
2.3 Panel Code Displays the Display Code number.
2.4 Bootloader ID ID of Bootloader.
2.5 NVM version Detects and displays NVM version.
2.6 Flash ID ID of flash model.
2.7 e-UM version eDFU (help) version.
2.8 Channel Table Structure Version version of channel table structure.
2.9 Error Codes Detects and displays errors.
3.1 Signal Quality Analog/digital signal strength.
3.2 Child lock Not active / active. This is a combined item for locks. If any lock (channel lock, parental lock) is active, it is indicated as “active”.
3.3 HDCP keys Indicates the validity of the HDMI keys (or HDCP keys). In case these keys are not valid and the customer wants to make use of the HDMI functionality, the SSB has to be replaced.
3.4 Ethernet MAC address A Media Access Control address (MAC adress) is a unique identifier assigned to network interfaces for communications on the physical network segment.
3.5 Wireless MAC address Wireless Media Access Control address.
How to Navigate
By means of the “CURSOR-DOWN/UP” knob (or the scroll wheel) on the RC-transmitter, can be navigated through the menus.
How to Exit CSM
To exit CSM, use one of the following methods.
> Press the MENU/HOME button on the remote control transmitter.
> Press the POWER button on the remote control transmitter.
> Press the POWER button on the television set.
Software Upgrading
Description
It is possible for the user to upgrade the main software via the USB port. This allows replacement of a software image in a stand alone set. A description on how to upgrade the main software can be found in the DFU or on the Philips website.
Introduction
Philips continuously tries to improve its products, and it’s recommend that the TV software is updated when updates are available. Software update files can be obtained from the dealer or can be downloaded from the Philips  websites.
Preparing a portable memory for software upgrade
The following requirements have to be met:
1. A personal computer connected to the internet.
2. An archive utility that supports the ZIP-format (e.g. WinZip for Windows or Stufflt for Mac OS).
3. A FAT formatted USB memory stick (preferably empty).
Note:
1. Only FAT/DOS-formatted memory sticks are supported.
2. Only use software update files that can be found on the Philips website.
Check the current TV software version
Before starting the software upgrade procedure, it is advised to check that what the current TV software:
1. Press the “1 2 3 6 5 4” button on the remote control to enter the CSM mode.
2. Use the up/down cursor keys to select “Current Main Software”.
If the current software version of the TV is the same as the latest update file found on philips.com/support, it is not necessary to update the TV software.
Download the latest software
1. Open the internet page philips.com/support.
2. Find information and software related to the TV.
3. Select the latest software update file and download it to the PC.
4. Insert the USB memory stick into one of the USB ports of the PC.
5. Decompress the downloaded ZIP file and copy it to the root directory to Update the TV software
1. Turn the TV on and wait for it to boot completely.
2. Insert the USB memory stick that contains the software update files in one of the TV’s USB ports.
3. The TV will detect the USB memory stick automatically.
Then a window jumps out.
Note: If the USB flash drive is not detected after power up, disconnect it and re-insert it.
4. Select [Update] and press OK.
5. To proceed, In next menu select [Start] and press OK to start software updates.
6. Upgrading will now begins and the status of the updating progress will be displayed.
7. When the TV software is updated. Remove your USB flash drive, then select [Restart] and press OK to restart the TV. f the USB flash drive.
Note:
* Do not remove the USB flash drive during the software update.
* If a power failure occurs during the update, do not remove the USB flash drive from the TV. The TV will continue the software update as soon as the power comes up again.
* If an error occurs during the update retry the procedure or contact the dealer.
* We do not recommend downgrading to an older version.
* Once the upgrade is finished, use the PC to remove the TV software from the USB portable memory.
Content and Usage of the One-Zip Software File Below you find a content explanation of the One-Zip file, and instructions on how and when to use it. Only files that are relevant for Service are mentioned here.
> EDID_clustername.zip: Contains the EDID content of the different EDID NVMs. See ComPair for further instructions.
> FUS_clustername_version.zip: Contains the file downloaded which is needed to upgrade the TV main software and the software download application.
> NVM_clustername_version.zip: Default NVM content.
Must be programmed via ComPair.
How to Copy NVM Data to/from USB
When copying data to and from a USB memory stick, the folder “repair” is used. When inserting an empty USB memory stick, and downloading data to the stick, the TV will create this folder.  When sending data from a USB memory stick to a TV, the intended data must be available in the “repair” folder.
Note that when copying EDID data to the TV, all necessary EDID files must be in this folder.
Error Codes
Introduction
Error codes are required to indicate failures in the TV set. In principle a unique error code is available for every:
* Activated (SW) protection.
* Failing I2C device.
* General I2C error.
The last five errors, stored in the NVM, are shown in the Service menu’s. This is called the error buffer.
The error code buffer contains all errors detected since the last time the buffer was erased. The buffer is written from left to right. When an error occurs that is not yet in the error code buffer, it is displayed at the left side and all other errors shift one position to the right.
An error will be added to the buffer if this error differs from any error in the buffer. The last found error is displayed on the left.
An error with a designated error code never leads to a deadlock situation. It must always be diagnosable (e.g. error buffer via OSD or blinking LED or via ComPair).
In case a failure identified by an error code automatically results in other error codes (cause and effect), only the error code of the MAIN failure is displayed.
How to Read the Error Buffer
You can read the error buffer in three ways:
> On screen via the SAM/CSM (if you have a picture).
Example:
* ERROR: 000 000 000 000 000: No errors detected
* ERROR: 013 000 000 000 000: Error code 13 is the last and only detected error
* ERROR: 034 013 000 000 000: Error code 13 was detected first and error code 34 is the last detected (newest) error
> Via the blinking LED procedure (when you have no picture).
Error codes
In this chassis only “layer 2” error codes are available and point to problems on the SSB. They are triggered by LED blinking when CSM is activated. Only the following layer 2 errors are defined:
How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
> By using the CLEAR command in the SAM menu
> By using the CLEAR command in the Factory mode:
> By using the following key sequence on the remote control transmitter: “062599” directly followed by the OK button.
> If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.
The Blinking LED Procedure
Introduction
The software is capable of identifying different kinds of errors.
Because it is possible that more than one error can occur over time, an error buffer is available, which is capable of storing the last five errors that occurred. This is useful if the OSD is not working properly.
Errors can also be displayed by the blinking LED procedure. The method is to repeatedly let the front LED pulse with as many pulses as the error code number, followed by a period of 1.5 seconds in which the LED is “off”. Then this sequence is repeated.
Example (1): error code 4 will result in four times the sequence LED “on” for 0.25 seconds / LED “off” for 0.25 seconds. After this sequence, the LED will be “off” for 1.5 seconds. Any RC command terminates the sequence. Error code LED blinking is in red color.
Fault Finding and Repair Tips
Note:
* It is assumed that the components are mounted correctly with correct values and no bad solder joints.
* Before any fault finding actions, check if the correct options are set.
NVM Editor
In some cases, it can be convenient if one directly can change the NVM contents. This can be done with the “NVM Editor” in SAM mode. With this option, single bytes can be changed.
Caution:
> Do not change these, without understanding the function of each setting, because incorrect NVM settings may seriously hamper the correct functioning of the TV set.
> Always write down the existing NVM settings, before changing the settings. This will enable you to return to the original settings, if the new settings turn out to be incorrect.
Load Default NVM Values
It is possible to upload the default values to the NVM with ComPair in case the SW is changed, the NVM is replaced with a new (empty) one, or when the NVM content is corrupted.
After replacing an EEPROM (or with a defective/no EEPROM), default settings should be used to enable the set to start-up and allow the Service Default Mode and Service Alignment Mode to be accessed.
No Picture
When you have no picture, first make sure you have entered the correct display code.
Unstable Picture via HDMI input
Check (via ComPair or factory mode) if HDMI EDID data is properly programmed
No Picture via HDMI input
Check if HDCP key is valid. This can be done in CSM.
TV Will Not Start-up from Stand-by
Possible Stand-by Controller failure. Re-flash the software.
Audio Amplifier
The Class D-IC U601 has a powerpad for cooling. When the IC is replaced it must be ensured that the power pad is very well pushed to the PWB while the solder is still liquid. This is needed to insure that the cooling is guaranteed, otherwise the Class D-IC could break down in short time.
CSM
When CSM is activated and there is a USB memory stick connected to the TV, the software will dump the complete CSM content to the USB memory stick. The file (Csm.txt) will be saved in the root of the USB memory stick.
Loudspeakers
Make sure that the volume is set to minimum during disconnecting the speakers in the ON-state of the TV. The audio amplifier can be damaged by disconnecting the speakers during ON-state of the set.
Display option code
Attention: In case the SSB is replaced, always check the Panel Code in CSM, even when picture is available. Performance with the incorrect display option code can lead to unwanted side-effects for certain conditions.
General Alignment Conditions
Perform all electrical adjustments under the following conditions:
* Power supply voltage: 90 - 264 VAC, 50/ 60 ± 3 Hz.
* Connect the set to the mains via an isolation transformer with low internal resistance.
* Allow the set to warm up for approximately 15 minutes.
* Measure voltages and waveforms in relation to correct ground (e.g. measure audio signals in relation to AUDIO_GND).
Caution: It is not allowed to use heat sinks as ground.
* Test probe: Ri > 10 MW, Ci < 20 pF.
* Use an isolated trimmer/screwdriver to perform alignments.
Hardware Alignments: Not applicable.
Software Alignments
Put the set in SAM mode (see Chapter 5. Service Modes, Error Codes, and Fault Finding). The SAM menu will now appear on the screen. Select RGB Align and go to one of the sub menus.
The alignments are explained below.
The following items can be aligned:
> White point.
To store the data:
> Press OK on the RC before the cursor is moved to the left.
> Select “Store” and press OK on the RC.
> Switch the set to stand-by mode.
For the next alignments, supply the following test signals via a video generator to the RF input:
> EU/AP-PAL models: a PAL B/G TV-signal with a signal strength of at least 1 mV and a frequency of 475.25 MHz
> US/AP-NTSC models: an NTSC M/N TV-signal with a signal strength of at least 1 mV and a frequency of 61.25 MHz (channel 3).
> LATAM models: an NTSC M TV-signal with a signal strength of at least 1 mV and a frequency of 61.25 MHz (channel 3).
RGB Alignment
White Tone Alignment:
> Activate SAM.
> Select “RGB Align.” and choose a color temperature.
> Use a 100% white screen as input signal and set the following values:
* “Red BL Offset” and “Green BL Offset” to “7” (if present).
* All “White point” values initial to “128”
In case you have a colour analyser:
> Measure with a calibrated (phosphor- independent) color analyser (e.g. Minolta CA-210) in the center of the screen.
Consequently, the measurement needs to be done in a dark environment.
> Adjust the correct x, y coordinates (while holding one of the White point registers R, G or B on max. value) by means of decreasing the value of one or two other white points to the correct x, y coordinates  Tolerance: dx: ± 0.003, dy: ± 0.003.
> Repeat this step for the other colour Temperatures that need to be aligned.
> When finished return to the SAM root menu and press STANDBY on the RC to store the aligned values to the NVM.
If you do not have a color analyser, you can use the default values. This is the next best solution. The default values are average values coming from production (statistics).
Display Adjustment
You can use the default values. The default values are average values coming from production.
> Enter SAM mode.
> Select a colour temperature (e.g. COOL, NORMAL, or WARM).
> Set the RED, GREEN and BLUE default values according to the values in back to div.table below
> When finished press OK on the RC, then press STORE to store the aligned values to the NVM.
> Restore the initial picture settings after the alignments.
This group setting of color temperature will be applied automatically to the TV / VGA / HDMI / AV sources.
Option Settings
Introduction
The microprocessor communicates with a large number of I2C ICs in the set. To ensure good communication and to make digital diagnosis possible, the microprocessor has to know which ICs to address. The presence / absence of these MT5580 ICs is made known by the option codes.
Notes:
* After changing the option(s), save them by pressing the OK button on the RC before the cursor is moved to the left, select STORE and press OK on the RC.
* The new option setting is only active after the TV is switched “off” / “stand-by” and “on” again with the mains switch (the NVM is then read again).
Option Code Overview
Enter SAM mode to check the option codes. they could be edited in the NVM.
Display Code Overview
Press the following key sequence on a standard RC transmitter: “062598” directly followed by MENU and “xxx”, where “xxx” is a 3 digit decimal value of the panel type: see column “Display Code” in the table below. After resetting the Display Code, restart the set immediately.
Reset of Repaired SSB
A very important issue towards a repaired SSB from a Service repair shop (SSB repair on component level) implies the reset of the NVM on the SSB.  A repaired SSB in Service should get the service Set type “00PF0000000000” and Production code “00000000000000”.
Also the virgin bit is to be set. To set all this, you can use the ComPair tool or use the “NVM editor” and “Dealer options” items in SAM (do not forget to “store”).
After a repaired SSB has been mounted in the set (set repair on board level), the type number (CTN) and production code of the TV has to be set according to the type plate of the set. For this, you can use the NVM editor in SAM. The loading of the CTN and production code can also be done via compare (Model number programming).
In case of a display replacement, reset the “Operation hours display” to “0”, or to the operation hours of the replacement display.
Remark:
* After the NVM has been replaced, go to SAM and scroll to the
<Reload MAC address>
* Select the item and press <OK> on the RC.
Reset of Repaired SSB
Instruction
After NVM replacement, reload MAC address via SAM menu.This ensures the correct MAC address to be available in CSM for future repair actions.
Way of working:
* After the NVM has been replaced, go to SAM and scroll to the <Reload MAC address> .
* Select the item and press <OK> on the RC.
Notes:
* Only applicable to all related models that are “Smart TV level 0”enabled (only YouTube access). For models without internet connection feature, no action is needed.
* HDCP keys are located in the NVM. If you are loading NVM with the ComPair tool, there is warning message displayed.  New NVM EEPROMs are shipped with pre-loaded HDCP keys.
SSB Identification
SSB’s of this chassis are identified by a “715” code on the SSB.
715Axxxx-Nnn-MMM-oooo
* 715 main category, Printed Wiring Board
* Axxxx sub category, sequential coding number
* Nnn Version code
* N Development number
* nn Production number
* MMM Mounting variation code
* oooo Optional variation code
Make sure when replacing an SSB the SSB identification codes match the replacement panel.

Monday, June 26, 2017

Sony LCD Monitor LMD2450W - How to enter service mode, adjustments

Service mode entry and adjustments - Sony 24 inch LCD Monitors LMD2450W, LMD2450MC, LMD2450MD, LMD2050W
Required tools and measuring equipment
Luminance meter :: Minolta CA-210, CA-110 or equivalent.
If equivalent is not available, make adjustment by comparing the LCD monitor with the reference monitor that has already been calibrated correctly.
Signal generator: VG-854 or equivalent.
Warm-up time
Before starting adjustment, allow a warm-up of minimum 120 minutes to stabilize the back light of the LCD panel.
How to enter service mode
1 Press the [MENU] button to display the MENU screen.
2 Press the [CONTROL] and [RETURN] buttons simultaneously.
Preparing the power supply and signals
1 Connect the supplied AC cord of this unit.  Power voltage: 100 to 240 V AC, 50/60Hz
2 Turn on the power of this unit.
White Balance Adjustment
If the LCD panel is changed, perform the white balance adjustment.
1 Move the cursor to SIGNAL using the Down  key and press the [ENTER] button to enter the SIGNAL layer.
2 Move the cursor to WHITE BALANCE using the Down  key and press the [ENTER] button to enter the SIGNAL/WHITE BALANCE layer.
To move the cursor to select an item, use the Up  or Down  key. To set the selected item, press the [ENTER] button.
D93 adjustment
1 Select D93 from COLOR TEMP and set it by pressing [ENTER] button.
Target value : x = 0.283, y = 0.298
2 Select ADJUST GAIN, and adjust the GAIN. Adjust using R and B while G is fixed.
3 Select ADJUST BIAS, and adjust the BIAS. Adjust using R and B while G is fixed.
4 Repeat steps 2 and 3 until all of the required specifications are met all at the same time.
D65 adjustment
1 Select D65 from COLOR TEMP and set it by pressing [ENTER] button.
Target value : x = 0.313, y = 0.329
2 Select ADJUST GAIN, and adjust the GAIN.
Adjust using R and B while G is fixed.
3 Select ADJUST BIAS, and adjust the BIAS.
Adjust using R and B while G is fixed.
4 Repeat steps 2 and 3 until all of the required specifications are met all at the same time.
D56 adjustment (LMD-2450MD/2450MC)
1 Select D56 from COLOR TEMP and set it by pressing [ENTER] button.
Target value : x = 0.330, y = 0.345
2 Select ADJUST GAIN, and adjust the GAIN.
Adjust using R and B while G is fixed.
3 Select ADJUST BIAS, and adjust the BIAS.
Adjust using R and B while G is fixed.
4 Repeat steps 2 and 3 until all of the required specifications are met all at the same time.
A/D Adjustment (COMPONENT)
1 Input the 575/50I 100% 8 color-bar COMPONENT signal to this unit.
2 Press the input switch to accept the COMPONENT input signal.
3 Enter the Service menu, then select SIGNAL > SIGNAL LEVEL > AUTO ADJ.
Perform the following automatic adjustments.
 Y/G LEVEL
 PB LEVEL
 PR LEVEL
 Y OFFSET
 PB OFFSET
 PR OFFSET
4 Perform the adjustments of items 1-2 to 1-4 in table shown below by repeating the above described procedures.  However, before performing AUTO ADJ, adjust the COMPONENT level or NTSC SETUP appropriately according to the respective conditions described in the table.

A/D Adjustment (RGB)
1 Input the 480/60I 100% 8 color-bar RGB signal to this unit.
2 Press the input switch to accept the RGB input signal.
3 Enter the Service menu, then select SIGNAL > SIGNAL LEVEL > AUTO ADJ. Perform the following automatic adjustments.
 Y LEVEL
 PB LEVEL
 PR LEVEL
 Y OFFSET
 PB OFFSET
 PR OFFSET
4. Perform the adjustment of item 1-6 in table  shown below by repeating the above described procedures.
A/D Adjustment (COMPOSITE)
1 Input the NTSC 100% 8 color-bar COMPOSITE signal to this unit.
2 Press the input switch to accept the COMPOSITE input signal.
3 Enter the Service menu, then select SIGNAL > SIGNAL LEVEL > AUTO ADJ. Perform the following automatic adjustments.
 Y/G LEVEL
 PB LEVEL
 PR LEVEL
4 Perform the adjustments of items 1-8 and 1-9 in table shown below by repeating the above described procedures.
A/D Adjustment (Y/C)
1 Input the NTSC 100% 8 color-bar Y/C signal to this unit.
2 Press the input switch to accept the Y/C input signal.
3 Enter the Service menu, then select SIGNAL > SIGNAL LEVEL > AUTO ADJ. Perform the following automatic adjustments.
 Y/G LEVEL
 PB LEVEL
 PR LEVEL
4 Perform the adjustments of items 1-11 and 1-12 in table 4 shown below by repeating the above described procedures.
A/D Adjustment (COMPUTER)
1 Input the COMPUTER HD15 640 x 480 60 Hz 100% 8 color-bar signal to this unit.
2 Press the input switch to accept the COMPUTER (HD15) input signal.
3 Enter the Service menu, then select SIGNAL > SIGNAL LEVEL > AUTO ADJ. Perform the following automatic adjustments.
 Y/G LEVEL
 PB LEVEL
 PR LEVEL
 Y OFFSET
 PB OFFSET
 PR OFFSET

Thursday, June 22, 2017

Attack MK4800 - Hi-power professional amplifier circuit diagram

Used power output transistor pair - 2SC5198, 2SA1941
Power supply schematic and PWB
LED VU drive schematic
Power amplifier circuit and PWB
Click on the pictures to magnify


Haier 48DR3505 LCD TV – how to enter service mode, adjustments, panel faults - Software update - MSD3393LU Chassis

How to enter into Service Mode
The way to the factory mode menu:
1: Press Menu
2: Input “8893
System will be into the factory mode menu when 2 steps above are done.
At the end of the main factory menu, you can see the edition of the software like this
" BUILD TIME 2014.09.15 23:45:32
   VERSION v1.0 ”.
How to exit
If you want to exit this factory menu, please press the button”Exit” on the remote.
System will be out the factory mode menu.
In factory mode menu, press up/down button to choose the up/down item, press right or OK button to the sub-menu. Press MENU button to go back.
General setting
1) Init Flash;
2) Uart Enable: Choose on or off in Uart Enable;
3) Dbg Message Enable: Choose on or off in Dbg Message Enable;
4) Test Pattern: Choose the Pattern picture;
5) Dynamic Contrast: Choose on or off in Dynamic Contrast;
6) Power On Mode: Choose on or off in Power On Mode;
7) Mirror Control: Choose on or off in Mirror Control;
8) Front End Status
9) Timer Test
10) SSC
11) Erase Flash
12) PQ Advance Debug: Choose on or off in PQ Advance Debug;
13) Factory remote: Open or close the Factory remote;
14) Factory CH Export.
Picture
Adjust the Picture Mode, Picture Curve,
White Balance and Over Scan in different source. 
Sound
Adjust the values of Sound Mode,
Volume Curve, Audio Output and True Volume in different source.
Panel Setting
1) LVDS Bit Mode: choose the Bit;
2) LVDS MAP: choose the MAP;
3) LVDS ODD/Even: choose ODD or Even;
4) Bcaklight:Adiust the value of backlight;
5) Reset Panel Setting Date
6) 6MX0 LVDS Map: choose the 6MX0 LVDS MAP;
7) 6MX0 Channel: choose the 6MX0 Channel;
8) 6MX0 Mirror: choose the 6MX0 Mirror;
9) 6MX0 Demo: choose the 6MX0 Demo;
10) 6MX0 Update.
MSD3393LU software update
1. Copy the software files to a USB disk on the root directory;
2. Insert the USB disk when the AC power is off;
3. Turn on the AC power in turn to begin;
4. Turn off the AC power until the indicator light fast twinkling;
5. Pull out the USB disk and power on the television.
Note: Do not turn off the TV while it is updating.
1. Mainchip—MSD3393LU(U1)
2. Audio Ampli
er—TPA3110D2PWPR (UA1)
3. Main Flash Memory—GD25Q32BSIG (UF1)
4. DC/DC convertor 5V-1.8V for MSD3393LU (U1)—LC1117CLTRAD (UL2)
5. voltage convertor 5V to 3.3V_STB —LC1117CLTR33 (UL1)
6. voltage convertor 5V to 1.15V_STB —LC3406CB5TR (UD1)
7. voltage convertor 5V to 3V for tuner—LC1117CLTR33 (UT1)
8. Tuner —SDCL1005CR33JTDF (RFT1)
Faults and possible reasons
Vertical bar, Vertal gray line, Vertical color line(light or dark forever)
Block Defect :TCP cracking or cracking
Dim or L/D :TCP Sunken
*TCP lead cracking
*ACF bonding short
*Awful environment and something electric enter into LCD
*Mis-align between TCP and Panel
*Panel failure
*TCP failure.
Horizontal bar, Horizontal gray line, Horizontal line(light or dark forever)
Bright dot dark dot in panel, Bladder in Polarizer, Polarizer Scratch
Abnormal Display, Bright and dark display alternately
1.Chip lose action
2. IC short or joint iog bad
3. Pannel and vsc connect bad
White Screen > B/L normal, only white screen display > Maybe caused by surge current and EDS
Black Screen > B/L normal, only Black screen display > Maybe caused by surge current and EDS
FIIcker > Crosstalk > LCD Vcom imbalance
Abnormal Color > Only color abnormal > Capacitance improper bring cross-talk inside LCD panel. 1.Chip lose action.  2.IC short or junction bad.  3. Panel and vsc connect bad
Mechanical Noise > When turn panel,appear cacophony > Caused by Mechanical noise of back-light unit.
Ripple > Concentric circle > Caused by between mechanism and panel
B/L off > B/L lose action > Connect badness between wire and electrode
B/L dark > B/L brightness darker than normal > Connect badness Short between wire and electrode.
B/L wire damaged, B/L wire open, B/L shut down > Operation abnormal or systemic noise Operation, abnormal or systemic noise, Short between lamp housing and wire, Because consume power too much. 
F/M > F/M in B/L ,white, black Rotundity or wire like > F/M in B/L unit
Light leakage > Brightness at the bottom of the LCM brighter than normal > B/L unit bad.
Mechanical or B/L 
Uniformity > B/L brightness asymmetric > Sheet in B/L unit is uneven
Mount hole > Lack screw or screw damage.