Applicable to these models
LC-32CHE5111E, LC-32CHE5111K, LC-32CHE5111KW,
LC-32CHE5112E, LC-32CHE5112EW, LC-32CHE6131K, LC-32CHE6132E, LC-32CHF5111K, LC-32CFE6132E,
LC-32CHE5221E, LC-32CHE6242E, LC-32CFE6241E, LC-32CFE6241K ,LC-32CFE6242E, LC-32CFE6352E,
LC-32CFE6452E, LC-40CFE5111E, LC-40CFE5112E, LC-40CFE5111K, LC-40CFE6132E, LC-40CFE5221E,
LC-40CFE5221K, LC-40CFE6241K, LC-40CFE6242E, LC-40CFE6351E, LC-40CFE6351K, LC-40CFE6352E,
LC-40CFE6452E, LC-43CFF5111K, LC-43CFF6001K, LC-43CFF6002E, LC-43CFE5111E, LC-43CFE5111K,
LC-43CFE5112E, LC-43CFE6131E, LC-43CFE6131K, LC-43CFE6132E, LC-43CFE6141EW, LC-43CFE6142EW,
LC-43CFE5222E, LC-43CFE6241K, LC-43CFE6242E, LC-43CFE6252EW, LC-32CFE6351K, LC-43CFE6351E,
LC-43CFE6352E, LC-43CFE6352K, LC-43CFE6451K, LC-43SFE7332E, LC-43CFE6452E, LC-43SFE7452E
Press
the RC buttons in this sequence: “Menu
1 1 4 7” to enter the factory
menu.
Description:
ROOT
0 Factory Init All
1 BURNNG MODE
2 ADC ADJUST
3 PICTURE
4 SOUND
5 PANEL
6 DEBUG
7 GENERAL SETTING
8 EMC SETTING
9 INIT CHANNEL
10 SW UPGRADE
11 SW INFORMATION
12 SHIPMENT (KEEP ADC)
13 6M50 SETTING *
14 SII9679 SETTING *
15 VTV1222 SETTING *
Factory menu Homepage
0
Factory Init All
Initialize
TV. Restore to factory configures.
1 BURNNG MODE
Aging
mode. For test panel. If it’s in operation, use key board “power” to quit.
2
ADC SETTING
It’s
for adjusting the YPBPR and PC color. Press key “right” or “ok” to enter the
subpage.
ADC Mode: Display current input
source and resolution.
ADC Auto Adjust: Start to auto
color to get ADC value.
[ADC]R-Gain: Display current ADC
R value.
[ADC]R-Offset: Display current
ADC R offset value.
[ADC]G-Gain: Display current ADC
G value.
[ADC]G-Offset: Display current
ADC G offset value.
[ADC]B-Gain: Display current ADC
B value.
[ADC]B-Offset: Display current
ADC B offset value.
3
PICTURE
SOURCE: Current input source. (use for change source)
STANDARD SETTING: Standard
analog quality setting (Like contrast ...etc) for different Picture mode. It
will change OSD picture menu’s standard picture mode setting.
NONLINE CURVE: The nonlinear
curve for picture mode. To set OSD quality setting (like contrast. brightness
...etc) the value 0,25,50.75.100 corresponding actual nonline curve value.
W/B ADJUST: Standard white
balance setting. Select warm - cold - normal mode and set its RGB value to
change OSD picture menu’s white balance standard value. R-Gain increase red
colour, G-Gain increase green colour, B-Gain increase blue colour.
Color Setting, Luma Setting, Peaking
Setting, NR Setting, CTI Setting, Gamma, DLC, Film Mode, PQ By Pass: Change
these setting will change register for PQ.
Suggest do not change these setting.
4
SOUND
SOURCE:
Current
input source. (use for change source)
SOUND MODE: Standard sound
setting (Like EQ treble bass) for different Sound mode .It will change Sound
menu’s standard sound mode setting.
EQ: sound in different frequency range value.
VOLUME CURVE: Volume curve. At
least ten steps is adjustable. To set sound value from 1 to 100 corresponding
actual nonline curve value. It will change current sound actual value. For
example, TAB-50 is 925, that’s on the sound OSD page, use key vol+or- to adjust
the value to 50, the volume is 925.
VOLUME SETTINGS: setting AVL
mode and threshold ...etc. AVD: auto volume control. Vol PreScale DTV... SCART:
Set different source’s sound value.
PEQ: Adjust the audio effect by
different frequency range. EQ: sound in different frequency range value. PEQ:
more frequency range than EQ;
5
PANEL
Backlight: It’s for adjusting the non-eco and eco backlight.
Depends on which mode is selected in OSD.
LVDS Map ID: Modify this
according to your panel. It is the combination of the TI Mode, Color Bits, Swap
Port and Output Bit.
LVDS TI Mode: Have VESA or JEICA
mode. It’s related to LVDS Map.
LVDS Color Bits: Set lVDS data
interface type. (6bit or 8bit or 10bit).
LVDS Swap Port: LVDS A or B Port
data swap.
LVDS Output Bit: Set LVDS data
output type. (6bit or 8bit or 10bit).
PWM Freq: Modify PWM frequency
PWM Fraq Step: The speed when
you modify PWM Freq value.
Mirror: mirror TV. Switch your
screen upside down.
6
DEBUG
MStar Fac Menu: Show MStar Factory Menu.
Uart Enable: To enable serial
port with print debug infomation. If you want to got the debug info by the ISP
tool, you can set this item to “ON”.
VIF setting: RF non-standard
signal test.
Erase MAC: erase Mac address. The
password is “4711”.
Erase HDCP Key: erase HDCP key.
Must erase key before upgrade key. The password is “4711”.
Erase HDCP2.0 Key: erase HDCP2.0
key. Must erase key before upgrade key. The password is “4711”.
Erase CIplus Key: erase CIplus
key. Must erase key before upgrade key. The password is “4711”.
Erase ADC: Erase ADC value. The
password is “4711”.
Erase WB: Erase white balance.
The password is “4711”.
Era&Gen NandBin: Erase All
and generate Nandbin (Use for production). The password is “4711”. It will
erase flash. This function is for CVTE test, Suggest do not erase this.
RB-Time: Suggest do not do
this. The password is “4711”.
Format USB device: Format USB,
your USB device will be NULL.
Print to USB: debug print
information output to USB device. Easy to get print out.
Logo On or Off: have power on logo
or not.
7
GENERAL SETTING
Test Pattern: Display test picture to check panel.
OVERSCAN: It’s for adjusting the
over scan of picture.
Timer Test: To speed up the
time. Only for QC test.
WDT: Watch dog on or off
Power On Mode: After power on
state. It’s for setting power state when power on. There are three option
off or on or last. ‘off’ means it’ll enter standby state; ’on’ means it’ll power on
directly without standby; ‘last’ means it’ll enter the last state : standby or
power on. It decided by the state when you turn off the power.
EN ADC Value: Use for keypad
test. Get keypad ADC value.
ADC Value: The ADC value of
current press key. Use this need EN ADC Value turn to on.
CI+ Version Switch: Switch CI+
Version both 1.2 and 1.3. It will lead TV restart.
Hotel Mode: Enter Hotel mode
setting.
Capture Screen: If set to ON, we
can capture screen when press setup key.
8
EMC SETTING
It’s
for adjusting some parameters about EMC.
9 INIT CHANNEL
CH Table import: import channel table from USB, need channel table in USB that
export before.
CH Table export: export channel
table to USB.
CH Table Init: Initial Channel
Table, It will be NULL.
10
Software Upgrade
Upgrade TV: For upgrade Software. Need UBS device and. bin file.
Bin name: .bin name for upgrade
11
SW INFORMATION
Mantis or OCS: The model of software.
Main board: The main board of
software to use.
Panel Name: The panel of
software to use.
AT version: The version of
factory auto test.
Build Time: The build time of
software. (ID of software)
Operation Time: The time of TV
total operation time counter.
12
Shipment (keey ADC WB)
Initialize
TV. Restore to factory configures. But keep ADC and WB configure.
Extern:
6M50, SII9679 and VTV1222 setting
item is used to boot or upgrade other chips in board. Only for 4K2K board.
SOFTWARE UPGRADE
MSD6308
Upgrade Instruction
6308
including 6308RT, 6308RTE, 6308RTEB and 6308RTEC, you should make sure the main
chipset correspond to the upgrade program before upgrading. This manual
provides 3 upgrading methods with 6308RT as the example, the three methods are:
User menu upgrade, Power on upgrade, TFTP (network) upgrade.
At the beginning of
upgrading, if prompt “PWM-REF doesn’t match”, please make sure the new software
PWM-REF won’t damage the panel, and then change the file name into AllUpgrade-6308-SOS.bin
and
power on to upgrade.
User Menu Upgrade
A Operation Procedure
•
Turn on the TV set
• Copy the bin file to the root directory of USB device
• Plug the USB device to the USB port
• Select “Software Update (USB)” on the OSD and follow the instructions. TV
will switch-off automatically after upgrading finished.
The upgrade process prompts as follows:
B
Upgrade Prompt
When
upgrading, the TV set will light panel according to the panel parameter, and
display the progress bar. If the panel parameter of board matches the panel,
you will see the following image:
C
Upgrade Flashing Status
You
can judge the upgrade progress by flashing of the remote control LED light.
Upgrading
Red 1000ms Green1000ms alternates, the TV set will turn to Upgrade succeed or Upgrade
Failed status after the upgrading process.
Main program upgrade succeed
Red 250ms Green 250ms alternates, flashing before power off.
Main program upgrade Failed
Red 1750ms Green 250ms alternates, flashing before power off.
• Notes:
• In the upgrade process, as timer software is used to control flashing,
situations such as LED light stuck when creating partition of flash, is normal
phenomenon.
6.3 Power On Upgrade
A Operation Procedure
• Power Off the TV set
• Copy AllUpgrade-6308XXX.bin to the root directory of your USB memory stick
• Plug the USB device to the USB port
• Power on the TV, if the upgrade file name matches the main chipset, the LED
light will flashing and the upgrade process starting. The TV set won’t auto
reboot after finishing the upgrade process, customer should pull the USB out
and power off the TV set manually.
TFTP (network) Upgrade
A Upgrade Tools
C
Upgrade Process
•
Connect serial port tools
• Connect the PC and main board with network cable, connect the serial port.
Set the cable adapter IP as 192.168.1.100.
Connect the serial port,
enter the following command to set main board and tftp server IP. setenv ipaddr
192.168.1.101 setenv serverip 192.168.1.100 saveenves
Notes:
Direct Connect network cable between PC and MB To Upgrade is
available in the version higher than svn5215.
•
Run the tftpd32.exe in your upgrading folder.
After setting IP, enter the
following command to upgrade the corresponding program.
Upgrade Mboot: mstar upgrade-mboot.txt
Reboot: reset
Re-enter command to set IP.
Upgrade main program: mstar
mscript/auto-update.txt
Notes:
auto-update.txt will clear factory burning parameter of KEY/MAC, please use it cautiously.
upgrade-mboot.txt and auto-update.txt are text files,
engineer can refer to the two text files when entering corresponding upgrade
command.
PICTURE ADJUSTMENT
White
Balance
•
Change source to HDMI
• Load 80% White pattern from signal generator
• Enter Factory Menu by pressing MENU + 1147
• Choose 3 Picture
• Choose 3 W/B Adjust
• In 0 WB Mode choose Warm or Normal or Cold
• Change R-Gain or G-Gain or B-Grain to meet specification
HOTEL MODE
To enter Hotel mode you
need press buttons on RC in following sequence: MENU 7 9 0 6.
Structure of Hotel menu:
1. Hotel Mode – on or off hotel mode
2. Source Lock – you can lock any source
3. Default Source – source which appears after turn on TV
4. Default Prog – channel which appears after turn on TV
5. DTV channel type – type of channel which appears after turn on TV
6. Default volume – volume which will be set itself after turn on TV
7. Max volume – maximum volume which can be set
8. CH Table Import – import all channels and settings from USB
9. CH Table Export – export all channels and setting to USB
10. Clear Lock – reset all hotel mode settings.
SMART TV TROUBLESHOOTING
TV cant connect to wi-fi network.
Steps
to fix this issue:
• Set on your wi-fi router/access point WPA or WPA2 encryption. WEP is not
supported.
• Set on your wi-fi router DNS to 8.8.8.8 (Google DNS server)
• If above does not help, try to upgrade software again.
2. Entering AQUOS NET+ is not possible
• Most probable cause may be missing or wrong MAC address.
Steps of test validity of MAC address:
1. Press MENU + 1147
to
enter factory menu
2. Go to 11 SW Information and
press OK (Pic.1)
3. Check item 10 Sraf Valid MAC
4. If there is (OK), it
means everything is ok (Pic. 2)
Note: It may take few seconds until “OK” shows after turning TV on.
5. If there is (NG), means
either MAC address is missing or is not supported by current SDK (Pic.3).
In case of NG test result:
1. Check 7 Mac Addr
2. If value is FF:FF:FF:FF:FF:FF
– this means MAC was not added during production of mainboard.
Solution to fix this issue: Request
new MAC addresses from TV manufacturer.
3. If value is different than FF:FF:FF:FF:FF:FF
– Means current address is not supported by software.
Solution to fix this issue: Upgrade
TV software to the latest version.