>> Cont > {2}
UPDATING FIRMWARE OF MAIN BODY
- Firmware update disc supports CD-R media.
Creating and Update Disc
- Download the update file from "JS-NET". The file name is "hdd_u.udx"
- Write update file into CD-R.
- Make sure the write in "Disc at Once".
- Set the comparability to "ISO9660 format". {ROMEO, JOLIET are disapproved].
- If writing method is not correct, the update results in an error.
There are two methods of updating firmware, using JIG mode <method-1> or not using JIG mode <method-2>. Updating can operate in both methods.
<Method -1>
- Set to the JIG mode.
- Load the update disc on tray, and then close the tray.
- When the disc reading operation is completed, transmit [43-70] with the JIG remote control unit. If the update disc is not correct, FL indicator will display "Error" after transmitting "43-70. Transmit [43-70] once and make the FL indicator to normal display, and then re-load the disc then transmit [40-70] again.
- "Update" is displayed in the FL indicator, and FL indicator changes to "FL UPDATE" afterwards. It takes approx. 2 minutes for the change.
- Remove the disc as the tray is ejected, and then transmit [43-70] with JIG remote control unit. Then the FL indicator changes from "Update" to the normal display.
- Close the tray, and turn the main body Off. Pull out the power cord from the wall socket. Then plug the power cord into the wall socket again.
- When "Loading" in the FL indicator disappears, turn the main body On.
- Display the 'System Information" menu. Check the version of the firmware.
- Cancel the JIG mode.
<Method - 2>
- Turn the power ON. Load the update disc on the tray and close the tray.
- When the disc reading operation is completed, turn the power Off.
- Keep pressing the "Pause" and the power button simultaneously until the FL indicator changes to 'Update".
- In approx. 2 minutes the tray is ejected. Remove the disc from the tray, and close the tray.
- Reset operation is carried out automatically, and becomes standby condition.
- Then, display the "System Information" menu in JIG mode and check the version.
Updating the Firmware of the Drive Unit.
- Turn ON the main body.
- Load the update DVD-RAM disc on the tray and close the tray.
- "Reading" is displayed in FL indicator disappears, open the tray and remove the disc and close the tray.
- In short while "Reading"in the FL indicator disappears, open the tray to remove the disc and close the tray.
- Turn the "Power" Off, and pull out power cord from the wall socket, then plug the power cord into wall socket again.
- Set to the JIG mode and check the firmware version of the drive.
TAKING OUT THE DISC
<Method-1>
- Right after plugging the power cord (while loading is displayed), keep pressing the Open / Close button of the main body.
- Remove the disc as the tray is ejected in a short while.
- Make sure to close the tray afterwards.
<Method -2>
- When the disc cannot be removed by operating above <method-1>, open the front door of the main body manually and directly press the "Eject" button located at the lower right of the drive unit.
<Method -3>
- Open the front door of the main body manually.
- Insert a fine wire {eg: a straightened paper clip} into the hole in the lower part of the tray of the drive unit.
- As the tray ejects a little, pull out the tray manually.