PANASONIC TX - W32D4DP SERVICE MODE ADJUSTMENTS



TO ENTER SERVICE MODE [FACTORY MODE]


  • To return customer settings ot Factory settings and clear owner ID of all information input by the user, enter Self Check Mode.  
  • Press Down ( -/V ) button on the customer control at the front of the TV set, at the same time pressing the "STATUS" button [ +] on the remote control.
  • To "Exit" Self Check, switch OFF the TV set at the Power Button.
  • Self check should only be used when refurbishing the TV set, and not during normal repair work.
     Self check is also used to automatically check the Bus Lines, and Hexadecimal code of the tV set. If CCU ports have been checked and found to be incorrect or not located, then "---" will appear in place of "OK"

SELF CHECK SCREEN

VPC
OK


TUN
OK
PCB
OK
E2
OK


DPL
OK
CAB
OK
CIP 1
OK


CIP 2
OK
SUM
Factory use only
VP
OK


DFU
OK


COL
OK


PIP
OK


OPTION 1
B9


OPTION 2
FD


OPTION 3
1F


OPTION 4
0D


OPTION 5
FB


OPTION 6
63



ALIGNMENT SETTINGS
  1. Set the 'Bass' to maximum position, set treble to minimum position.  Press the Down Button ( - / V ) on the customer controls at the front of the TV and at the same time press the "INDEX' button on the remote control, this will place the TV into the Service Mode.
  2. Press the 'Red'/'Green' buttons to step up / down through the functions.
  3. Press 'Yellow' / 'Blue' buttons to alter the function values.
  4. Press "STR" button after each adjustment has been made to store the required values in memory.
  5. To "EXIT" service mode, press the "N" button.
Alignment function

Settings / Special features

Horizontal position
H-pos [+020]
Optimum settings
Vertical position
V-pos [+024]
Optimum setting
Horizontal amplitude
H – amp [+049]
Optimum setting
Vertical amplitude
V –amp [+029]
Optimum setting
EW-Amplitude
E/W Amp-1 [+022]
Optimum setting
EW- amplitude
E/W Amp-2 [000]
Optimum setting
Trapezium-comp
Trapez-1 [+033]
Optimum setting
Horizontal - parallel
H-Parallel [+032]
Optimum setting
Vertical linearity
V-Lin [+044]
Optimum setting
DVCO
DVCO [0000]
Receive a PAL color bar pattern.  For DVCO alignment press “Blue” button, wait until colors are stable and press ‘STR’.

Cut-off DC
Cut-off [OK]
To adjust cut-off adjust the screen VR until the display shows “OK”.

Highlight
High – 0031  0031  0031
Contrast       Maximum
A.I               Off
Optimum setting.
Sub brightness
Sub-brightness [0000]
Optimum setting.