Monday, September 17, 2012

PHILIPS PLASMA PWB DEFECTS - SYMPTOMS - Plasma TV Screen Faults

                                          [2]

SYMPTOM
DESCRIPTION
RELATED BOARD

No voltage output
Operating voltages doesn’t exist.
PSU
No display
Operating voltage exists, but no display
Y-main, X-main, Logic main, Connections.
Abnormal display
Abnormal image
Y-Main, X-main, Logic Main.
Sustain open
Some horizontal lines doesn’t exist on the display
Scan Buffer, FPC of X | Y
Sustain short
Some horizontal lines appear to be linked on display
Scan buffers, FPC of X | Y
Address open
Some vertical lines don’t exist on the display
Logic Main, Logic Buffer, FFC, TCP
Address short
Some vertical lines appear to be linked on display
Logic Main, Logic Buffer, FFC, TCP


ADDRESS OPEN [vertical stripe]
ADDRESS SHORT [vertical stripe]
ADDRESS OUTPUT ERROR -1
ADDRESS OUTPUT ERROR - 2
SUSTAIN OPEN {One or more line, horizontal direction, do not light up in sustain direction}
SUSTAIN SHORT -1 {Combined or adjacent lines are in sustain short direction.  The line appear brighter than the other at the ramp gradation pattern or low gradation pattern.
SUSTAIN SHORT - 2
ADDRESS BLOCK & LINE OPEN
ADDRESS BLOCK & SUSTAIN OPEN
DIELECTRIC MATERIAL LAYER DAMAGE:
Symptom:  Phosphor damage caused by the damage of address bus dielectric layer appears in the panel discharge/ non discharge area.  Sustain  also open/short occurs by the damage  of address sustain printout.  Cause: Layer uneven / abnormal voltage/ foreign material repair failed.
FULL WHITE LOW DISCHARGE:  Low discharge caused  by unstable cells occurring at a full white pattern if high or normal temperature.
Example 1
Weak discharge:  Normal discharge, but cells appear darker to weak light emission occurring mainly at low full white/red/green/blue pattern or graduation pattern.
DEFECTIVE TCP.
42" SDV2 MODULE LAYOUT