[2]
HOW TO COPY BACKUP DATA
When the digital assembly is replaced with one for service [Usual Service]
HOW TO COPY BACKUP DATA
When the digital assembly is replaced with one for service [Usual Service]
- Copying using Factory Menu
- Plug in the AC cord, press the Power switch ON the unit to set it ON, then enter Standby Mode.
- Turn ON the Power, using remote control unit, then panel Factory mode. [Panel Information > [key Dn] > ETC [key +] > [key 'Set'] > Backup Data:NoOPRT [key >>] > Backup Data :Transfer [key 'Set' (5sec)].
- Turn the Power OFF.
- After the digital assembly is replaced with one for service, be sure to check if 'NO DATA!' is set for "DIG.EEP" on the PANEL INFORMATION.
- If copying of back up data fails in the above procedure, the Red LED lights, and the Blue LED flashes, as warning that no backup data was copied.
- If both 'digital' and 'Sensor Assemblies' are to be replaced, first replace the 'Sensor' assembly, turn the unit ON, and back OFF again, then replace the 'digital assembly'
- Copying using RS-232 commands
- Switch the RS-232C/SR+ setting to RS-232C so that RS-232C commands can be received.
- Turn ON the unit, using the remote control unit by issuing the 'PON' command. Then issue'FAY' command
- Issue the 'BCP' command to transfer the data stored in the EEPROM for back up.
- Turn Power Off.