[7]
BOTH THE TIMER AND TEMPERATURE LEDs BLINKS
- Are fans running?
- If yes, Replace Actuator Board.
- If fans do not tun, Check for 8Vdc at [CN103 & 104].
- If the voltage is present, replace fan. [Check which one is defective, and replace it]
- If the voltage at [CN-103&104] are not good;
- Check [CN-802 pin 8, 10] on the Power board for 12VB.
- If OK, Replace the Actuator board.
- If not good, Remove Power and check the DMD, Actuator and Digital boards for short circuit on 12V line go Ground.