FUJITSU - PDS5003W_PDS5004W _ Troubleshooting Chart



 LED LAMP BLINKING

State of lamp





Not lighted
Check power supply PCB

Check PDP Panel

Red
Blinks continuously
Power turned off immediately.

Check PDP panel.

Red
Blinks once
Power turned Off after 10 seconds.

Check-1

Red
Blinks twice
Power turned Off after 10 seconds.

Check – 2

Red
Blinks 4 times
Power No turned Off, LED blinks only.

Replace Main/Digtal PCB ass’y.

Red
Blinks 5 times.
Power not turned Off, LED blinks only.

Replace Video PCB Ass’y.

Green
Lights steadily for more than 10 seconds





Is on On Screen Display normal?


No

Check PDP panel.



Yes




All input image faulty.
Signal processing PCB faulty.
Replace Main / Digital PCB Ass’y.



Video input image faulty.
Video PCB faulty.
Replace Video PCB Ass’y.



S-Video input image faulty.
Video PCB faulty.
Replace Video PCB Ass’y.



Component video input image faulty.
Signal processing PCB faulty.
Replace Main / Digital PCB Ass’y.



RGB 1,2 input image faulty.
Check – 3.






TEMPERATURE PROTECTOR OPERATED:  Power Lamp Flashes intermittently Twice in Red.[for 0.5 seconds at an interval of  5 seconds]


Is ambient temperature of IC757 on Main Digital PCB less than 60 degree C?


No
Adjust PDP unit installation so that peripheral temperature is 40 Degree C or less.


Yes




Does unit operates normally when temperature sensor IC757 changed?


No
Microcomputer peripheral circuit faulty.

Replace Main/digital PCB Ass’y.

Yes
Temperature sensor IC757 faulty.
Replace temperature sensor IC757.



FAN PROTECTOR OPERATED:  Power Lamp Flashes once intermittently in Red [for 0.5 seconds at an interval of 3 seconds]


Is voltage at connectors P951 3pin, P953 3pin and P954 3pin on Main/digital PCB 14V?



Yes
Fan faulty.
Replace the fan.

No
Microcomputer peripheral circuit faulty.
Replace Main/Digital PCB Ass’y.