HISENSE - PDP 4220 _ PLASMA TV_ SERVICE MODE AND SOFTWARE UPDATE PROCESS



TOOLS

  • To update use this special RS232 cable.
  • This RS232 cable includes a 9-pin D-Sub Female, a 3.5mm Stereo Earphone Plug and 3 wires.

UPDATE STEPS
  • Prepare a PC, and install update software.
  1. Install 'GPROBE5.0 
  2. Copy GM1601FW file document to "C:\"
  3. Copy three files of GF to chipdb file document.
  4. Use "batch C:\gm1601fw\ISP\batch\FlashRom_7.txt" command.
  • Connect the cable.
  • Connect the 9 pin D-Sub Female end to computer, and connect the stereo earphone plug end to RS232 terminal on the back panel of the PDP.
  • Run the application GPROB5.0, then input command, "batch C:\gm1601fw\ISP\batch\Flashrom_7.txt"
  • Turn On the PDP, and updating process begins.  [Warning:  Must not turn OFF the PDP in the updating process]
  • When updating finishes, it will display successfully.
  • Turn Off the TV, and then turn it ON again.
SERVICE MODE

  • Using [balance] + [0532]:  Press 'Balance' item, and then press number [0, 5, 3, 2] button AT-ONCE.
  • Service Mode Menu includes; White Balance, Voice Settings, Picture Settings, Options & Auto Color.