Saturday, October 13, 2012

MEMOREX & DURABAND - DBTV 1341 _ SERVICE MODE & ADJUSTMENTS



TO ENTER SERVICE MODE

  • Unplug AC till lost actual clock time.  
  • Press & Hold [Volume ( - ) button on the 'TV' and on the remote control simultaneously.
  • The both pressing of the set key remote control key will not possible if clock has been set.   Unplug the AC cord and allow at least 5 seconds before Power On


Set key
Remocon key
Operations


0
Releasing V-Chip password


1
Initialization of the Factory.  Do not use this for the normal servicing.


2
Horizontal position adjustment of OSD


3
Adjust the PG shifter automatically.


4
Adjust the PG shifter manually.

Vol ( --) Min For all
5
Adjusting of tracking to center position.


6
Power On Total Hours.


8
Writing of EEPROM initial data.


9
Display of the adjustment Menu on screen.


Method
Operations

Press the ATR button on the remote control for more than 2 seconds during ‘Play’.
Adjusting the Tracking to the center position.

Make the short circuit between the test point of Service and GND
The EOT | BOT | Reel sensor do not work at this moment.

No comments: