                                              [5]

Symptom:  A blank vertical cell or block appears on the screen as follows:




  • Address Buffer defect: Replace the corresponding Upper | Lower Buffers. [E or F].
  • COF defect:  Replace the Module.  (COF = Chip On Film)
===============================================================


  • Symptom:  A green screen appears when the TV is turned On. No image at all
  • The Scale is not resetting.   Replace the Main Board.
===============================================================

Symptom:  The OSD box appears, but there is no TEXT.




  • Incorrect program version.  
  • Check the version of each program.
  • Replace the Main Board.
===================================================================

Symptom:  A blank Upper | Lower block appears on the screen.
  • Upper or Lower Y-Buffer defect.  
  • Replace corresponding Upper | Lower Buffers. [E or F]
===================================================================

Symptom: Either the Main or Sub-Picture does not appear.


  • Replace the Main Board.
==================================================================

Symptom:  A vertical Green line appears on the screen.



  • The SMPS out voltage is incorrect.
  • Adjust the SMPS voltage, according to the voltage printed on the module label.
=================================================================

Symptom;  Dim screen. Blurred in red.




  • X-Main board defect.  
  • Replace X=main board.
=================================================================

Symptom:  A blank screen appears.

  • Replace the Y-Main Board.
==================================================================