SELF DIAGNOSTIC FUNCTION [Standby/Power LED blinking codes]

  • When an error occurs, the Standby/Timer LED will flash a set number of times to indicate the possible cause of problem.  If there is more than one error, the LED will identify the first of the problem areas.
  • Results for all the following diagnostic items are displayed on the screen.  No error occurred  the screen displays a "0".
Diagnostic item
Lamp flashes
Diagnostic result
Probable cause location
Detected symptoms

Power does not turn on
Does not light
-----------
# Power cord is not plugged in. # Fuse is burned out [F601]. {A board}
# Power does not come on.
# No power is supplied to the TV.
# AC power supply is faulty.

+B over current protection (OVP)
2 times
2:1 or 2:0
H.OUT [Q502] is shorted. {A board}. # IC702 is shorted {C board}

# Power does not come on.
# Load on power line is shorted.
I-Port
4 times
4:1 or 4:0
# +13V is not supplied {A board}.  # IC561 faulty {A board}
# Has entered standby state after horizontal raster. 
# Vertical deflection pulse is stopped.
# Power line is shorted or power supply is stopped.

IK (AKB}
5 times
5:1 or 5:0
# IC001 is faulty {M board}.  # Screen (G2) is improperly adjusted.
# No raster is generated.
# CRT cathode current detection reference pulse output is small.


 *  If a +B over current is detected, stoppage of vertical deflection is detected simultaneously.  The symptom that is diagnosed first by the microcomputer is displayed on the screen.

Stopping the Standby/Power LED Flash
Turn Off the Power switch on the TV main unit or unplug the power cord from the AC outlet to stop   it from flashing.

DISASSEMBLY

KV-27FS320 IS PICTURED



Service Position


BOARDS



KV-27FS320 MODELS _ CABLE WIRE DRESSING









KV-32FS120 | KV-34FS120 MODELS





KV-32FS320 MODELS_ By next post.

No comments:

Post a Comment