APEX - AVL 3076 APEX - AVL 2776 _ LCD TV _ SYSTEM BIOS UPGRADE PROCEDURE





Use RS-232 to link computer RS232 port (If no RS232 port can use USB transform) and LC2700W RS232 port.




  • The CPU used for processing ISP need to burn LD0415.BIN to the LDROM of CPU.  (Have burned before shipping).
  • Need to enter factory mode by press { (MENU) + (VOL+) + (VOL - ) } on OSD to execute ISP mode.






  • Push Menu.  Push “►” button to access Factory Mode.





  • Press”” button to “ISP” item.  When press “Vol+” TV will be locked.



  • Execute ispwriter.exe file
  • To execute CPU ispwriter.exe file on your PC, and the below screen appears:




  • Move the cursor to click “Select Chip” button and select the type of CPU (W78E65).



  • Move the cursor to click  [check] Program Start at APROM” to cancel the selection.


  • Move the cursor to click “Select Bank0” button to select the wanted program. The file format is binary format instead of hex format.



  • Select the Port Name on Communication Setting screen.



  • Move the cursor to click “Connect” button to link. If the linking succeeds, below screen will appear.



  • Click “Program All” button to auto-execute erase and program function. After execution below screen will appear. Click “confirm” button to finish the execution.



  • To click “verify” button to execute verify function. After verification, below screen will appear. Click “confirm” button to finish the verify function



  • After updating APROM program, disconnect ISP tool. Power on LCD TV again.