CONNECTORS
- Check each section with following method if there is problem, replace or repair that part. If not go to the next section.
- Confirm every Connector (PSU, Y-SUS, CTRL, Z-SUS). => module may not be normal by mis-connection which can not send signal and power. Also Mis connection for a long time has a specific b/d failed.
CTRL B/D + Y - SUSTAIN [NO DISPLAY]
CTRL B/D + Z-SUSTAIN
CTRL B/D + X - B/D
SIGNAL INPUT [LVDS]
- Confirm exhausting Tip and find Crack with naked eyes to check vacuum state. If there is problem replace the module. in case of vacuum breakdown, module makes a shaking noise because of inside gas ventilation. (there may be a small crack which could not see with naked eyes. And this noise is different from Capacitor noise)
NORMAL
CRACKED
- Check 3.3V, 5V,15V.
- Confirm LED D17(flashing) ,13 lighting. If not CHECK OSC X1 output.
- Check CTRL input voltage (CONNECTOR P300).
- Check IC 11 3.3V IC 3 2.5V.
Input voltage.
Diodes
IC - 11 [(+3.3V): IC - 3 (+2.5V)
Oscillator: Check oscillating state. Normal is 100MHz. Probe touching point.
Contd: