Many of the latest (released after 1993) model Sony TV's have a built in Self- Diagnosis function.
If the timer/standby
indicator is blinking, this could be an indication of the problem with the
unit. The diagnostic blinking will occur automatically with no action required
by you to engage it.
The timing of the
blinking you see would be as follows: two to eight blinks (depending on the
fault) about a third of a second apart, then pauses for 3 seconds, then the two
to eight blinks about a third of a second apart again. Here is a list of the problems that might
have occurred indicated by the number of blinks. The words in parentheses are
those which you will see for each of these faults on a diagnosis screen
described later in this article.
Unit is dead and
there are no blinks _ Problem in the standby power section. Might check fuse,
R607, Q601, IC601, R612 and VDR601 (should
show open).
Continuous Blink
Once A Second, No Pausing As Discussed Above
No reply from the
jungle IC301 (data bus is busy, shorted to ground or held high), IK video path
is defective.
ONE
Blink _ not used for the
self-diagnosis.
TWO Blinks _ B+ over current
protection (OCP) , unit goes to the standby mode then displays the 2 blink
fault. Could be a short in the power supply of any of the circuits.
THREE Blinks _ B+ over voltage
protection (OVP), unit goes to the standby mode then displays the 3 blink
fault. This is also a problem in the power supply circuit, check T603 and R672.
FOUR Blinks _ No Vert. Deflection
(V STOP), Screen goes to a single horizontal line then the video signal muted.
Check IC1509, Q1505.
FIVE Blinks _ AKB circuit (AKB),
the timer/standby indicator blinks for about 30 seconds then goes to the
self-diagnosis function. Something is wrong with the video. Check video out,
Q705, 732, 761 and other components on the C-board, also check Q218, 219, 220
on the A board. Also unit be in IK blanking, try turning up screen slightly.
SIX Blinks _ No Horizontal (H
STOP), no raster, goes to the blinking self diagnosis function immediately.
Check C515 & 516 and the jungle IC, IC206.
SEVEN Blinks _High voltage
shutdown. The high voltage has exceeded 33k and the unit goes immediately into
safety shutdown. Check power supply regulation and horizontal circuits.
EIGHT Blinks _ Problem with the
audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check
IC406 audio amp, PS401 and 402.
Intermittent
problems is great feature. You can also bring up these fault codes ON-SCREEN to
see a list of the problem numbers with the
abbreviation of the
problem and the number of times this problem has occurred. This is slightly
different than entering the service mode. To see the
diagnostic screen,
Press the following buttons: Display,
Channel, 5, Vol Minus, ( Not plus ) then Power.
This brings up a
screen with a list of the problems and number of times they have occurred. Each of the problem names is abbreviated as,
"OCP", "OVP", "V STOP", ETC.
Say that you have a
set with a black screen. You see that the LED is blinking 4 times. This would
tell you that you have no vertical and that is why the video is muted. If it
was blinking 6 times, you would know that you have a horizontal fault.
IMPORTANT: After repair
the unit, clear the values on this diagnostic screen. These codes
do not reset themselves after the fault is corrected, so if you don't clear
them, you'll be seeing "old" fault codes the next time you enter this
screen.
Clearing is done by going into the Service Mode - (Display, Channel-5, Volume (+), then Power) then press 8 and Enter, which of course returns everything to the factory-preset condition. The above said procedure is common to enter Service Mode to most models of Sony Televisions.
Clearing is done by going into the Service Mode - (Display, Channel-5, Volume (+), then Power) then press 8 and Enter, which of course returns everything to the factory-preset condition. The above said procedure is common to enter Service Mode to most models of Sony Televisions.