ERROR CODES
- Error 000:No problem.
- Error 011:I2C bus error. When this error occurs, the TV will not start up due to the blocked bus.
- Error 012:Tuner error. There is no I2C communication towards the tuner after start-up.
- Error 013:Panel VCC error. This voltage is made in the power supply and results in protection in case of absence.
TO CLEAR THE ERROR BUFFER
- By using the CLEAR command in the SAM menu.
- By using the following key sequence on the remote control transmitter: “062599” directly followed by the OK button.
- If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
- Note: If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.
BLINKING LED
The software is capable of identifying different kinds of
errors. Because it is possible that more than one error can occur over time, an
error buffer is available, which is capable of storing the last five errors
that occurred. This is useful if the OSD is not working properly. Errors can also be displayed by the blinking
LED procedure. The method is to
repeatedly let the front LED pulse with as many pulses as the error code
number, followed by a period of 1.5 seconds in which the LED is“off”. Then this
sequence is repeated.
Error code 4 will result in four times the
sequence LED “on” for 0.25 seconds / LED “off” for 0.25 seconds. After this
sequence, the LED will be “off” for 1.5 seconds. Any RC command terminates the sequence.
Error code LED blinking is in red color.
Example (2):
The content of the error buffer is “12 9 6 0 0”
After entering SDM, the following occurs.
- 1 long blink of 5 seconds to start the sequence.
- 12 short blinks followed by a pause of 1.5 seconds.
- 9 short blinks followed by a pause of 1.5 seconds.
- 6 short blinks followed by a pause of 1.5 seconds.
- 1 long blink of 1.5 seconds to finish the sequence.
- The sequence starts again with 12 short blinks.
RESET OF REPAIRED SSB
- A very important issue towards a repaired SSB from a Service repair shop (SSB repair on component level) implies the reset of the NVM on the SSB.
- A repaired SSB in Service should get the service Set type “00PF0000000000” and Production code “00000000000000”. Also the virgin bit has to be set. To set all this, you can use the ComPair tool or use the “NVM editor” and “Service Data” items in SAM (do not forget to “store”).
- After a repaired SSB has been mounted in the set (set repair on board level), the type number (CTN) and production code of the TV has to be set according to the type plate of the set. For this, you can use the NVM editor in SAM. Loading of the CTN and production code can also be done via ComPair (Model number programming).
- In case of a display replacement, reset the “Operation hours display” to “0”, or to the operation hours of the replacement display.