Tuesday, August 13, 2013

TOSHIBA_HOW TO ENTER SERVICE MODE TO TOSHIBA COLOR TELEVISIONS (Various Models)


SERVICE MODE ENTRY METHODS
TOSHIBA – 2989UE / 2989UH / 2989XP
Entering into service mode
Press [Mute] button once on the remote control handset.
Once again press and hold remote handset [mute] button.
While keeping the Mute] button pressed, press [Menu] button on TV set.
Displaying the adjustment menu
Press [menu] button on the TV set to shift from adjustment mode to service mode and vice versa.
Service mode keys
     Select adjustment item by pressing the [channel+] or [channel-} button on the remote        control handset.
     Adjust data value by pressing the [Volume+] or [Volume-] button on the remote control handset.
Cancellation of service mode
To return to normal TV mode, press Power] / [Standby] button to turn off TV once

Service mode adjustments

Following adjustments items will appear on the screen.

Item         Name of adjustment                                             Reference data
R CUT     R CUTOFF B/W                                                              40H
G CUT    G CUTOFF                                                                      40H
B CUT     B CUTOFF                                                                      40H
GDRV     G DRIVE                                                                         40H
BDRV     BLUE DRIVE                                                                   40H
CNTX      SUB-CONTRAST MAX(4:3 MODE)                                  7FH
BRTC      SUB BRIGHT CEN                                                          7FH
COLC      SUB COLOR CEN NTSC                                                  39H
TNTC       SUB TINT GEN                                                                40H
COLP      SUB COLOUR CEN PAL                                                  39H
COLS      SUB COLOUTR CEN SECAM                                          27H
SCOL      SUB COLOUR                                                                 13H
SCNT      SUB CONTRAST                                                              2H
VOLS      VOL SCART                                                                     75H
FVOL      FM VOL PRE SCALE                                                       15H
NVOL      NICAM VOL PRE SCALE                                                 3AH
NICL        NICAM THRESHOLD LEVEL                                           03H
NICH       NICAM THRESHOLD LEVEL                                            0AH
IDL          IGR THRESHOLD LEVEL                                                 04H
IDH         IGR THRESHOLD LEVEL                                                 0EH
EVOL      EXT PRE VOLUME                                                            01H
EMX        NICAM ON LEVEL                                                             FCH
EMN        NICAM ON LEVEL                                                             64H
FMA        FM ATTENNUATOR LEVEL                                              00H
STS         STEREO SEPERATION                                                     00H
HPOS     50HZ HORIZONTAL POSITION                                        FEH
VPOS      V-POSITION                                                                      0DH
HIT          HEIGHT                                                                             3EH
VLIN        V-LENEARITY                                                                   17H
VSC        V-S CORRECTION                                                              18H
VPS         V-SHIFT                                                                             0CH
VCP         V-COMPENSATION                                                            07H
WID         PICTURE WIDTH                                                                18H
PARA      E-W PARABOLA                                                                  22H
CNR        E-W CORNER                                                                      04H
TRAP      TRAPEZIUM                                                                         0FH
HCP        H-COMPENSATION                                                            01H
VFC         V-F CORRECTION                                                              0FH
BELL       SECAM BELL FILTER                                                        80H
SRY        SECAN R-Y                                                                          08H
SBY        SECAM B-Y                                                                          08H

INITILIZATION OF MEMORY DATA OF QA02
 After replacing IC the following initialization is required.
  Enter the service mode then select any register item.
  Press and hold the [call] button on the remote then press the [channel+] button on      the TV.  The initialization of IC has been completed.
  Check the picture carefully.  If necessary, adjust any adjustment item as explained below.
Perform auto search memory as explained in the owner’s manual.
CAUTION:- Never attempt to initialize the data unless memory IC has been replaced.
Test signal selection
      In the service mode, pressing of [AV] / [Video] button shows the test patterns on screen.  Every pressing of [AV] / [Video] button cycle through 14 NTSC test patterns and 14 PAL test patterns.

Some of the test patterns are:

        Red single colour, green single colour, blue single colour

Black single colour, white single colour
White balance adjustment pattern
Black cross- bar, white crossbar
Black crosshatch, white cross hatch
Black cross dot, white cross dot, h signal etc.
 White balance adjustment
   Cutoff adjustment [RCUT] [GVUT] [BCUT]
   Drive adjustment [GDRV] [BDRV]
  • Set contrast to 40, and brightness to +20 by picture control.
  • Set the TV in service mode, and get the inside W/B adjustment signal with [AV/Video] button.
  • Select R CUT, G CUT, AND B CUT with [Channel+/-] buttons, to set individual values to 32, and to set GDRV and BDRV to 20 with [Volume+/-] buttons.
  • Press [-/--] button on the remote control and rotate screen VR to get one slight horizontal line on screen.
  •   Every pressing of [-/--] button provides horizontal line picture and o\normal picture    alternately.
  • Press [-/--] button to release horizontal line picture, and select the two other colours which did not light in the above step with  [CHANNEL+/-].  Then tap [Volume+/-] buttons so that three colors slightly light in the same level..
  • To correct white balance in light area, select GDRV and BDRV with [CHANNEL+/-] buttons to adjust.
  • To correct white balance in dark area, perform fine adjustment to RCUT, GCUT and BCUT.

Self-diagnostic function.
  •      Press [9] button on the remote control during display of adjustment menu.
  • The diagnosis will begin to check if interfaces among ICs are executed properly.

During diagnosis the following displays are shown.
                                         -----------------------------------------------------------------------
                                         <Self check>

                                         2390****

                                         power                                                             00
                                         bus line                                                          OK
                                         bus cont                                                        OK
                                         block                                                              UV V1 V2
                                                                                                                     QV01
                                         ------------------------------------------------------------------------
  Values 1-5 are explained below

Part number of micro control

  • Operation number of protecting circuit-“00” is normal.     When indication is other than “00”, over-current apts to flow, and circuit parts may possibly    damaged.

BUS LINE CHECK OK  NORMAL
“SDA 1- GND” means that SDA line is shorted to ground
“SCL - GND” means that SCL line is shorted to ground.
“SCL 1-SDA 1” means that SDA line is shorted to SCL line
      bus cont “OK” is normal
When indication shows “Q000 NG”, the device with the number may possibly damage.
        Block
UV-TV reception mode
V1-VIDEO 1 INPUT MODE (AV1)
V2-VIDEO2 input mode (AV 2)
Indicated colour of mode now selected: Green and Red.
Indicated colour of other modes: White.
Green ; Normal
Red : the microcomputer operates to provide judgment of no video signal.  The red color is still indicated through the signal is input 
QV01: In case of indication green-normal. In case of indication red with input signal -     
 failure may exist in output line including QV01.
TOSHIBA – 2150 / 2876DD / 2988DG

Entering into service mode.
Press [Mute] button.  Press and hold [Mute] button and press [Menu] on local keyboard.
Service mode keys
Select [PR+/-], adjust [VOL+/-],Store; [Auto], test picture [AV] 
Cancellation of service standby.      

No comments:

Post a Comment