SCHEMATIC DIAGRAM
Power Output, RMS
60 watts per channel into 4 Ohms , 20- 20,000Hz
90 watts per channel into 2 Ohms, 20- 20,000Hz
180 watts bridged mono into 4 Ohms, 20- 20,000Hz
CLICK ON THE SCHEMATICS TO ZOOM IN
PROTECTION CIRCUIT
If the temperature inside the CA260 rises above 80 Degree-C the
protection circuit comes into operation, decreasing output. At this time the
protect indicator blinks. If the temperature comes back below 80 Degree-C by
natural cooling, output returns as it was.
If the temperature
rises above 100 Degree-C, the power supply circuit is shut off. Not only does
the output stop, but also the protect indicator goes out. If this happens, it is
possible that the CA260 is broken. However, even in this state, it cannot be
always said that it is broken because the unit may operate when the temperature
comes back below 80C by natural cooling.