The configurations should be same as described in the previous post.

Configuration setup

  • Access Factory Mode.
  • Press 'Power' button.  Then quickly press 'Volume - and Volume + and hold these two buttons.  The screen comes out 'Waiting for automatic Adjustments", then the screen will be black for one second, until comes out "Windows Screen" => then release these tow buttons, then press 'Menu" button, wait until the OSD menu with characters "F1/FL1 NAFTA V0 91.1041124 ADJUST"
  • Push to exit OSD.
  • Click 'write EDID' icon from the toolbar to write DDC data.  Then the screen will be black for 2-3 seconds, then the screen recovers, and 'ATTENTION NO VIDEO INPUT' will come on the screen of the monitor, wait for 20-30 seconds, DDC data will be finished writing.
Save DDC Data.

Sometimes you may need to save DDC data as a text file for using  in other IC chip.  To save DDC data, follow the steps below.
  • Click 'Save' button or [click file -> save as] from the tool bar and give a file name .  Type the file type is EDID46 file(*.ddc) which can be open in WordPad, the texts of DDC data & table [128 bytes, hex code] can be modified.  if DDC TEXTS & HEX Table are completely correct, it can be saved as .ddc file to re-load into DDC IC for DDC Data application.


  • Click 'save'.
EXIT DDC program
  • Pull down the file menu, and select 'Exit'.

Turn OFF the Monitor, Exit the factory Mode.

Re-programming DDC IC follows by next post.