Thursday, October 04, 2012

SAGEM AXIUM - HD - D45EU FAULT DIAGNOSIS - DISSEMBLE

AXIUM ARCHITECTURE
For 'Axium' choice has been mad to use 2 trapezoidal mirrors with two main advantages.
  1. Reduction of the product depth.
  2. Possibility to setup the image geometry by acting on the <<small>> mirror with completely fixed optic.
The front panel LED allow to get a first level of diagnose regarding breakdown.  
A colored code using the indicators have been instaured  in order to detect different type of breakdowns.  When a problem is detected , the set goes automatically to standby; except in the case of incident on the optical engine, it is possible to reset the TV.
'LED' BINKING CODES

State
Temperature indicator

Lamp indicator
Stand-by indicator
After powering [in-standby]
----
----
Fixed Red.
Out of standby
----
----
Flashing Orange
Step 1 of the standby phase
----
----
Flashing Green
Step 2 of standby phase
----
----
Flashing Orange
Out of standby phase – Life duration of the lamp: 7500 hours
----
Flashing Red-10 seconds and then Off.
Flashing Orange.
Out of standby phase – Life duration of the lamp : 8000 hours.
----
Flashing Red 10 seconds, then Fixed Red for 5 seconds, then shutdown.
Flashing Orange
Temperature of optical engine
Fixed Red
--
Flashing Orange | Fixed Red.
Temperature fromatter
Fixed Red
Fixed Red
Flashing orange | Fixed Red.
Thermal switch
Fixed Red
Fixed Red
Flashing Orange | Fixed Red.
Lamp fan
Flashing Red
Flashing Red
Flashing Orange | Fixed Red.
DMD fan
Fixed Red
Flashing Red
Flashing Orange | Fixed Red.
Color wheel
----
Flashing Red
Flashing Orange | Fixed Red.
Lamp problem
----
Flashing Red
Flashing Orange | Fixed Red.




DISASSEMBLE MODULES
Removal of card door.
  • Remove the right cap.
  • Remove 2 screws.
  • Disconnect the cable from the card door and its lug.
  • Unscrew the two screws torx CBLX x 3*8
  • Remove the card.
REMOVAL OF THE MAIN BOARD CARD
  • Remove back plate.
  • Remove the right trap.
  • Remove the left trap.
  • remove the right and left corners.
  • Remove 2*2 screws CBX4*12
  • Remove back plate.
  • Remove 8 screws from the RCA and SCART base plates.
  • Remove two hexagonal spaces of DVI base plate.
  • Remove three scres
REMOVAL OF THE MAIN BOARD AND ITS SHIELDING
  • Gently unplug; without pulling the cables and lugs; situated at the back of the upper part of the card.
  • remove 8 black screws, and a steel screw
  • Remove the rear shielding | main board unit.
  • Remove then the last 5 steel screws to exchange the main board.
DISASSEMBLING POWER SUPPLY
  • Remove 4 screws
  • Pull it towards front, until able to unwire.  Start to unwire the upper cables.
  • Remove 7 screws 
  • Unplug the cable of internal sector as well as the Ground resumption lug.