Monday, March 30, 2015
LG XD Ultraslim CRT TV 29FU1RL- RG - RLD SMPS DEFLECTION and SYSTEM CONTROL CHROMA JUNGLE - SCHEMATIC
Professional technician for all kind of electronic equipment. Doing since 1974.
SONY Trinitron KVG14Q2 Repair Help FROM MY SERVICE TABLE TODAY
TDA8374A (Chroma)_STR S6707 (SMPS switching)_LA7830 (Vertical Scan Output IC)_ Sharp PQ 09RE 11 (9V controlled voltage regulator IC) _ 2SD1877 (Horizontal Scan Output Transistor)_NX1733/m (FBT/LOT)
Set
received for repair with no picture condition; today.
On
power ON, the standby LED blinks 3 times and then shuts off.
As
the standby LED blinks, at least once time, it is clear that the SMPS section
circuit to this set is working properly.
But,
the main system control micro-computer IC detects something short circuit with
any component/s at the main board.
As
the set is a very old model, the spare part availability will be somewhat
difficult. So; I should take much care with
work; not to damage more components.
I
opened the back cover. A visual
inspection is done for any damaged component/s on-board. Such as bulged/shorted capacitors, damaged
IC/s and such.
I
found that the vertical scan output IC is cracked. I’ve attached the photo of the same here.
Checked
all other main components, which can likely to be faulty; using
multi-meter. Checked the Horizontal
Output Transistor for any leak with its junction The Horizontal Output
Transistor used with this set is D1877.
I did notice, it is the original one fitted by the company. Nobody have replaced it. We can detect this by inspecting its solder
terminals.
Yet,
de-soldered it out from the circuit board, and checked it alone using meter set
to KOhms range. No abnormal measurement
noticed. De-soldered it into place
again. Screwed it on to its heat sink.
De-soldered
out the damaged vertical scan output IC from the circuit board.
Switched
ON the set without it.
The
standby LED lighted up once, then 3 times and OFF, as before.
[With
this set’s circuit, it won’t switch ON properly, or produce EHT or even a
horizontal line will appear on the screen, as other company’s sets will; except the +B voltage
[112VDC] only will be present.
I
did check the +B112VDC. It was OK. No fluctuations. Checked the voltage at the primary winding of the line drive transformer, and at
the collector terminals of the Line Drive Transistor. All found OK.
Switched
OFF the set, and checked all the solder terminals at the solder side of the
PWB, once more; using a magnifying glass.
After
some time, at about 25 minutes, I detected a minute loose solder terminal at
the 9V voltage regulator IC. This IC has
4 solder terminals. It is a controlled
voltage regulator, which in turn controlled by the main microcomputer IC. If the microcomputer IC detect any short
circuit anywhere at the circuit board, it will shut down the control voltage to
this IC; and it will down the 9VDC, which goes to the main chroma oscillator jungle
IC [TDA8374A], and that was happening here.
But
here there were two faults. The loose
solder terminal at the regulator IC said above (IC521 Pin-1). The vertical scan output IC (LA7830) short.
Re-checked
all the solder terminals at the main board to make sure that there are no other
loose solder terminals.
Set
switched on; fed to RF signal [On-Air].
Tuned it. OK.
Professional technician for all kind of electronic equipment. Doing since 1974.
Sunday, March 29, 2015
VIDEOCON 21 inch CTV REPAIR HELP From MY SERVICE TABLE TODAY - Retrace Lines all over the screen
Retrace lines all over the screen _ High brightness _ Audio
OK _ Faint picture
FBT Number to this set is BSC24-01N 4013E
In most cases, there are two
reasons for this retrace lines. The
first one is with a high screen voltage.
In rare cases, the screen-pot meter [built inside the FBT] might be
faulty. If so, there is no repair to
this fault, other than replace the FBT/ [LOT].
The second possibility is reduced
video output stage supply voltage. This
voltage is generated by one among the winding of the FBT. For some sets, it will be from the main SMPS
section itself. This supply voltage may
vary from 280VDC to 290VDC. It will
depend upon the model & circuit of the TV. The most probable reason for a low video
output stage supply voltage is, either the diode that rectifies this voltage at
the FBT winding end is faulty; or the smoothing capacitor used with this DC
supply line has open. The capacitor
used here might be 10MFD to 22MFD; electrolytic type of high voltage rating. Usually it will be 10MFD350VDC.
If this capacitor is open, the DC
voltage will drop considerably, causing a very low voltage at the cathodes of
the CRT gun; which in turn make it high emitting (electron) state, causing a
screen of too high intensity along with vertical retrace lines. The lines will appear across the screen; all
over it, at a space of 1 or 2 inches.
They will be slightly slanted too; in position. I've attached the photograph of the effected TV
screen here.
What I did first is to check the
supply voltage to the video output section [CRT base card]. It was found normal here. And the fault
should be of an abnormal screen voltage.
When I noticed closely to the
screen, there is a very faint picture, but, it was or normal in size. Slightly expanded than normal.
The +B voltage from the SMPS
section should be suspected. I did check
it. According to the schematic, it
should be 108.5VDC at load.
But, here it shows about
117.7VDC. Much more than normal. Adjusted it.
There is a pot-meter on board at the SMPS stage circuit to this set. It can be adjusted. The SMPS of this set is an adjustable type,
not auto.
Ahh: It worked fine. No other adjustments have to do here. Cleaned the inside of the set and circuit
board using hot air blower. My work is over. Delivered after 2 hours check.
AFTER THE ADJUSTMENT
SCREEN POT-METER POSITION Here I haven't adjusted it any more
Professional technician for all kind of electronic equipment. Doing since 1974.
Saturday, March 28, 2015
V GUARD DELUXE50 FIRDGE STABILIZER – Repair Help Fom MY SERVICE TABLE TODAY
V-Guard Fridge Stabilizer Deluxe 50 - Dead - No Input & output LED lights up. No output voltage.
Condition
: Dead. No input or output LED light up.
Used
a pre-programmed IC CTM1273 to control the circuit board PWB.
On
checking, the thermal fuse found damaged.
Replaced the thermal fuse (inserted inside the primary side of the transformer). Power light came alive, but there was no output LED light up; or any output voltage; even after 5 minute duration.
Replaced the thermal fuse (inserted inside the primary side of the transformer). Power light came alive, but there was no output LED light up; or any output voltage; even after 5 minute duration.
Checked
the components on circuit board. The
relay used (on board) HJR-3FF-S-2 was found not working. It's winding was open. Replaced the same; and checked OK.
When
checking this stabilizer, please check the AC fuse [the thermal fuse in the
transformer] first; then the Relay. This fuse can be
replaced. Pull that fuse out (after de-solder its two connections). Insert a new one in place and solder the
terminals as it was. I’ve marked both
the damaged component that I’ve replaced.
Note the photographs attached.
If
the pre-programmed IC said above is found damaged, contact the authorized
service center for V-Guard. There is no
way to get it from open electronic spare part market.
Professional technician for all kind of electronic equipment. Doing since 1974.
Friday, March 27, 2015
KONKA LED lcd tv 32F3000C SUPRA STV LCS26740 - TV SCHEMATIC POWER and BACKLIGHT INVERTER
Professional technician for all kind of electronic equipment. Doing since 1974.
Tuesday, March 24, 2015
LG HT306SF Power Supply and Power Amp circuit diagram _ Firmware Update
LG HT306SF –
HT306SH36F-S – HT306SH36SUW Home Theater System – Firmware Upgrade _ Power Amp & SMPS (Power
Supply) Schematic. USED ICs LC87F5M64A_M24C16_TAS 5352
HOW TO ENTER SYSTEM INFORMATION
* Enter into SETUP menu with NO Disc in the tray.
* Put on cursor [Highlight] 16:9 wide option of TV aspect in SETUP menu.
* Press follow key in continuous using remote control. 1 > 3 > 9 > 7 > 1 > 3 > 9 > ENTER
* Put on cursor [Highlight] 16:9 wide option of TV aspect in SETUP menu.
* Press follow key in continuous using remote control. 1 > 3 > 9 > 7 > 1 > 3 > 9 > ENTER
HOW TO UPDATE THE DVD and AUDIO MICOM PROGRAMS
The Whole Sequence
> DVD program download.
> Power cord Out > In.
> Audio micom program download.
> Remote control Pause key ‘||’ + ‘1472’ for input options.
> Enter into the system information for check the version, options and check sum.
> Power Off > On.
> Power cord Out > In.
> Audio micom program download.
> Remote control Pause key ‘||’ + ‘1472’ for input options.
> Enter into the system information for check the version, options and check sum.
> Power Off > On.
HOW TO UPDATE THE MTK-DVD PROGRAM
* Change the filename to download as
“LG_(MODEL NAME).ROM”. [Both Upper and
Lower case In filename is possible] Ex.)
HT306: “LG_HT306.ROM”
* Copy the file to the formatted USB, and burn it.
* Move to the USB function, and insert the USB to the set. The upgrade information will be shown on the screen.
* Remove the USB, press PLAY key of the remote control.
* Remove and reconnect the power cable when it changes to logo screen from upgrade information. Then the upgrade process is completed.
* Copy the file to the formatted USB, and burn it.
* Move to the USB function, and insert the USB to the set. The upgrade information will be shown on the screen.
* Remove the USB, press PLAY key of the remote control.
* Remove and reconnect the power cable when it changes to logo screen from upgrade information. Then the upgrade process is completed.
HOW TO UPDATE THE AUDIO-MICOM PROGRAM
> Change the filename to download as
“(MODEL NAME)_(Version).HEX”. Only upper cases are permitted. Ex.) HT306: "HT306_0809262.HEX"
> Copy the file to the root folder of USB storage.
> Put the USB into the SET, and move to the USB function. Then the upgrade process will be started with the upgrade information.
> If the upgrade process is complete, the set will be power off automatically with “Complete” message.
> Copy the file to the root folder of USB storage.
> Put the USB into the SET, and move to the USB function. Then the upgrade process will be started with the upgrade information.
> If the upgrade process is complete, the set will be power off automatically with “Complete” message.
HOW TO CLEAN THE LENS
If there is dust on the lens surface,
the dust should be cleaned away by using an air bush (such as used for camera
lens). The lens is held by a delicate spring. When cleaning the lens surface,
therefore, a cotton swab should be used, taking care not to distort lens.
Never attempt to disassemble the
pick-up.
Spring has excess pressure. If the lens is extremely dirty, apply isopropyl alcohol to the cotton swab. (Do not use any other liquid cleaners, because they will damage the lens.) Take care not to use too much of this alcohol on the swab, and do not allow the alcohol to get inside the pick-up.
Spring has excess pressure. If the lens is extremely dirty, apply isopropyl alcohol to the cotton swab. (Do not use any other liquid cleaners, because they will damage the lens.) Take care not to use too much of this alcohol on the swab, and do not allow the alcohol to get inside the pick-up.
POWER Supply & POWER Aamplifier CIRCUIT DIAGRAM [SCHEMATIC]
Power PWB Top & Bottom view
POWER AMP
CLICK ON THE PICTURES TO MAGNIFY
Professional technician for all kind of electronic equipment. Doing since 1974.
Monday, March 23, 2015
LG DU34FZ20 - SMPS and DEFLECTION SECTION SCHEMATICS
Professional technician for all kind of electronic equipment. Doing since 1974.
Sunday, March 22, 2015
THOMSON 52W610 HOW TO ENTER SERVICE MODE - CONVERGENCE ADJUSTMENTS
Service mode & convergence adjustments _ Thomson 52TW610_ 52”
Projection TV [PRTV]
SERVICE MODE
* Switch the TV into “Standby”
mode by pressing the Standby button on the RCU.
Wait till the TV goes into the standby.
* Press the VOL(--)button and then the PR(--)button on the TV keyboard. Hold them down for more than 8 seconds.
* After the normal switch on time, when the 8 seconds have elapsed, the main service menu appears on the screen.
* Press the VOL(--)button and then the PR(--)button on the TV keyboard. Hold them down for more than 8 seconds.
* After the normal switch on time, when the 8 seconds have elapsed, the main service menu appears on the screen.
* Press Exit on the Remote control.
Everyday use menu can be accessed via Menu button. (Text and EPG
not available)
Field Service Menu can be re-entered via Blue button.
In service mode
> The child lock function is re-initialized
> Clear any wake-up/sleep/memo/EPG timers
> Pin 8 of the scart plug has to be ignored.
> AV- Link WSS detection and letterbox detection (autoformat) have to be disabled.
> EPG and TELETEXT have to be disabled.
> Automatic standby functions, in case of no antenna signal have to be disabled.
> All passwords have to disabled.
> Installation Mode disabled.
> Default format and zoom.
> The Chassis Variant will be checked and stored
> The child lock function is re-initialized
> Clear any wake-up/sleep/memo/EPG timers
> Pin 8 of the scart plug has to be ignored.
> AV- Link WSS detection and letterbox detection (autoformat) have to be disabled.
> EPG and TELETEXT have to be disabled.
> Automatic standby functions, in case of no antenna signal have to be disabled.
> All passwords have to disabled.
> Installation Mode disabled.
> Default format and zoom.
> The Chassis Variant will be checked and stored
CONVERGENCE ADJUSTMENT PROCEDURE
For every point on the screen, each of the three beams has a
specific correction possibility in both horizontal and vertical planes. To
achieve this, three levels of adjustment are available in the Service Mode. The
unit is also equipped with an alignment grid pattern generator incorporated on
the convergence circuit board.
IN SERVICE MODE Select the “CONVERGENCE”
Select “LEVEL 1,2 or 3” menu line and LEVEL 1,2 or 3 ALIGNMENT
menu will appear.
LEVEL 1 ALIGNMENT MENU
* Press the“ OK”
button on the RCU to activate the Red-Green test grid pattern.
* Confirm that the Green geometry is correct.Green adjustable only at level 2 and 3.
* Press the“ RED” button on the RCU to activate the red test grid, the cursor will be set to the centre point on the red grid.
* Using the“ NAVIGATION” (“ up,“” down,“ ” left and “” right) buttons on the RCU, align the red central cursor position to the green centre grid reference point. A long press on the associated“ NAVIGATION” button on the RCU will accelerate the step size of the adjustment.
* Press the“ OK” button on the RCU to advance to the next cursor position and repeat the alignment process until all twenty five (9th = screen bottom left) alignment position have been checked.
* Press the“ EXIT” button on the RCU to return to“ Level 1” menu.
* Select” RETURN” on the menu.
* Next select“ STORE” on the convergence menu.
Repeat the alignment procedure for“ BLUE” in pressing the blue button to activate blue-green test grid pattern.
* Confirm that the Green geometry is correct.Green adjustable only at level 2 and 3.
* Press the“ RED” button on the RCU to activate the red test grid, the cursor will be set to the centre point on the red grid.
* Using the“ NAVIGATION” (“ up,“” down,“ ” left and “” right) buttons on the RCU, align the red central cursor position to the green centre grid reference point. A long press on the associated“ NAVIGATION” button on the RCU will accelerate the step size of the adjustment.
* Press the“ OK” button on the RCU to advance to the next cursor position and repeat the alignment process until all twenty five (9th = screen bottom left) alignment position have been checked.
* Press the“ EXIT” button on the RCU to return to“ Level 1” menu.
* Select” RETURN” on the menu.
* Next select“ STORE” on the convergence menu.
Repeat the alignment procedure for“ BLUE” in pressing the blue button to activate blue-green test grid pattern.
LEVEL 2 ALIGNMENT MENU
> Press the“ OK”
button on the RCU to activate the Green test grid pattern, this is used
throughout the alignment procedure as a reference.
> Confirm that the Green geometry is correct.
> Press the“RED” button on the RCU to activate the red test grid, the cursor will be set to the centre point on the red grid.
> Using the“ NAVIGATION” (“up,“” down,“” left and “” right) buttons on the RCU, align the red central cursor position to the green center grid reference point. A long press on the associated “NAVIGATION” button on the RCU will accelerate the step size of the adjustment.
> Press the“ OK” button on the RCU to advance to the next cursor position and repeat the alignment process until all twenty five (25th = screen bottom left) alignment position have been checked.
> Confirm that the Green geometry is correct.
> Press the“RED” button on the RCU to activate the red test grid, the cursor will be set to the centre point on the red grid.
> Using the“ NAVIGATION” (“up,“” down,“” left and “” right) buttons on the RCU, align the red central cursor position to the green center grid reference point. A long press on the associated “NAVIGATION” button on the RCU will accelerate the step size of the adjustment.
> Press the“ OK” button on the RCU to advance to the next cursor position and repeat the alignment process until all twenty five (25th = screen bottom left) alignment position have been checked.
> Press the“ EXIT” button on the RCU to return to“ Level 2” menu.
> Select” RETURN” on the menu.
> Next select“ STORE” on the convergence menu.
Repeat the alignment procedure for“ BLUE
> Select” RETURN” on the menu.
> Next select“ STORE” on the convergence menu.
Repeat the alignment procedure for“ BLUE
LEVEL 3 ALIGNMENT
Each one of the 195 alignment point can be reached by Using the NUMERICAL buttons 2 (up), 8 (down), 6 (right) and 4 (left) on the RCU
to position the cursor on the screen.
Convergence alignment is done using the“ NAVIGATION” (“up,“ ” down,“” left and“” right) buttons on the RCU.
* Press the“EXIT” button on the RCU to return to“ Level 3” menu.
* Select “RETURN” on the menu.
* Next select “STORE” on the convergence menu.
Convergence alignment is done using the“ NAVIGATION” (“up,“ ” down,“” left and“” right) buttons on the RCU.
* Press the“EXIT” button on the RCU to return to“ Level 3” menu.
* Select “RETURN” on the menu.
* Next select “STORE” on the convergence menu.
[Once “Level 3” alignment is completed, do not use“ Level 2”
otherwise all adjustments made in“ Level 3” will be ERASED.]
Convergence defaults
If the convergence alignment is completely wrong most adjustments can be made starting with the factory convergence values, these are stored in the NVM as default values. Default Red/Green/Blue:All of the colours convergence default. Values are stored in the Convergence RAM IC.
Default Red
Default Green
Default Blue
Restore: copies the last stored values from the NVM to the convergence RAM IC.
Store: Copies all Convergence RAM values to the NVM.
If the convergence alignment is completely wrong most adjustments can be made starting with the factory convergence values, these are stored in the NVM as default values. Default Red/Green/Blue:All of the colours convergence default. Values are stored in the Convergence RAM IC.
Default Red
Default Green
Default Blue
Restore: copies the last stored values from the NVM to the convergence RAM IC.
Store: Copies all Convergence RAM values to the NVM.
Professional technician for all kind of electronic equipment. Doing since 1974.
TCL and THOMSON LCD TV SMPS and INVERTER SCHEMATIC 01 LS182C0 PWB
Professional technician for all kind of electronic equipment. Doing since 1974.
Saturday, March 21, 2015
JVC AV30W475 - CRT TV - SMPS CIRCUIT DIAGRAM - URC set up codes
SMPS Schematic & PWB SMPS part at the Main Board_ JVC AV-30W475 - AV-30W475 _ CRT TV _ Universal remote control set-up codes to check with JVC brand TVs.
PWB - SMPS PART at main board (Solder Side)
UNIVERSAL REMOTE CONTROL SET-UP CODES
0007 0018 0075 0103 0123 0154
0163 0170 0182 0214 0225 0409 0433 0465 0657 0670
Professional technician for all kind of electronic equipment. Doing since 1974.
GRUNDIG LCD TV - SMPS SCHEMATIC - FSP115 and FSP223 - Service Mode
FSP-115 & FSP-223 - SMPS_Grundig LCD TV 26GTX3000T
Universal remote control set-up codes to check with Grundig brand TVs
Universal remote control set-up codes to check with Grundig brand TVs
FSP-115 SCHEMATIC & PWB -Solder Side
FSP-223 SCHEMATIC & PWB - Solder Side.
CLICK ON THE SCHEMATICS TO MAGNIFY
Calling up the Service Mode:
* Press button i (M).
* Enter the code number 8500
* Press button i (M).
* Enter the code number 8500
FUNCTIONS OF BUTTONS
M (i)
- Call up / exit the dialog center
▲▼
– call up the dialogue line [point mdnu]
OK
– Call up menus
◄►
- Changing the settings
(Z)
or [<=] - Sub menu – back to the main menu
Main
menu: Exit the service mode.Universal remote control set-up codes
0018 0039 0049 0080 0090 0101
0119 0145 0152 0194 0195 0217 0221 0232 0233 0247 0250 0384 0407 0421 0454 0620
0637 0644 0658 0810 0813
Professional technician for all kind of electronic equipment. Doing since 1974.
HOW TO ADJUST CONVERGENCE - HITACHI Projection TVs _ WD7000 - FD7000 - FL7000
HITACHI Projection TVs _ WD7000 - FD7000 - FL7000 - Convergence for outside digital & Convergence data adjustment procedure
Convergence for Outside Signal function
1. Press Service Switch on POWER/DEF P.W.B then display "Normal
Crosshatch"
2. Press [MENU] key on R/C, then display "Red + Green Crosshatch
with Red Marker" or "Green Crosshatch with Green Marker" or
"Blue + Green Crosshatch with Blue Marker"
3. Press [MENU] key on R/C again, then display "Normal
Crosshatch on Main Picture"
4. Press [MENU] key on R/C again, then display "Cross Marker +
Box Marker on Main Picture"
5. Press [MENU] key on R/C again, then display "only Box Marker
on Main Picture"
6. Press [MENU] key on R/C again, then display "Normal
Crosshatch" again.
[And repeat procedure 2) ~ 6) by each press [MENU] key on R/C]
Convergence Data Adjustment Method
This function can adjust convergence data of all of one line (or
all of screen) at the same time, in CONVERGENCE ADJUSTMENT MODE.
> Press Service Switch on DEF/CONVER P.W.B. to set to CONVERGENCE
ADJUSTMENT MODE, then display Normal Crosshatch with Adjustment Point Marker.
> Press [SUB] key on R/C, then Extra horizontal lines appeared as
set to RATER POSITION ADJUSTMENT MODE.
If Adjustment Point is on center, by press cursor key on R/C, then
Convergence Data of all of screen are exchanged at the same time. By press [UP] [LEFT] key on R/C, move up
(left) RED convergence data of all of screen.
If Adjustment Point is NOT on center, by press cursor key on R/C,
then Convergence Data of all of one line that Adjustment Point Marker is
existing are exchanged at the same time.
By press [UP] [LEFT] key on R/C, move up (left) RED convergence
data of all of horizontal (vertical) line that Adjustment Point Marker is
existing.
Press [SUB] key on R/C again to exit RATER POSITION ADJUSTMENT MODE
Professional technician for all kind of electronic equipment. Doing since 1974.
Subscribe to: