ADJUSTING PROCEDURE
- Get ready the PC with COM port (RS-232C) running on Windows 95/98/ME/2000/XP operating system, as well as the RS-232C cross cable.
- Start the unit with the RS-232C cable connected.
- Start the terminal software. (The freeware readily available on the Internet will do.)
- Make the following settings.
Baud rate => 9,600 bps
Data LENGTH => 8 bit
Parity bit => None
Stop bit => 1 bit
Flow
control => None
- If the settings are correct, the terminal software indicates “ERR” against pressing of the “ENTER” key.
- After the settings are done correctly, it is possible to make an adjustment by typing in the command shown in the table below and pressing the “ENTER” key on the keyboard.
- Command entry is successful if the terminal software indicates “OK” when the “ENTER” is pressed. If “ERR” is shown, retry to enter the command.
- Send the process mode switching command to switch from the RS232C operation mode to the process mode.
KRSW0001: “ERR” is returned.
KKT10037: When “OK” is returned,
the process mode becomes active. When “ERR”, start over from KRSW0001.
- Send each adjustment command.
INITIALIZATION TO FACTORY SETTING
CAUTION:
When initialization is performed, all user setting data including the channel
settings are initialized. Be cautious when making this adjustment.
(The
adjustments done in the adjustment process mode are not initialized.)
ADJUSTMENT ITEM => Initialization.
ADJUSTMENT CONDITION => It
turns off with AC power supply.
ADJUSTMENT PROCEDURE:
Enter the adjustment process mode.
Bring the cursor on to [INDUSTRY
INIT]
Set to [ON] using [VOL] key, and
press [ENTER] to execute the initialization.
When the version number screen
shows up on the green background and “SUCCESS” gets displayed at the top on
screen, it means the procedure has been successfully carried out.
(If an
error occurs, “ERROR” is displayed on the red background.)
- Turn off the AC power.
- #Never shut off the power during the initialization process.
The following settings are initialized in this adjustment.
- User setting
- Channel data (e.g. broadcast frequencies)
- Password data
- Operation time
- Auto installation flag
- V-CHIP block setting
After the adjustment, cancel
the adjustment process mode.
To exit the adjustment process
mode, unplug the AC power cable from the outlet to make a forced shutdown.
(When the power was turned off with the remote controller, once unplug the power
cable and plug it again. In this case, wait 10 seconds or so before plugging.)