Power unit operation check
Are the power cord and harness in the
unit properly connected? => NO => Connect the power cord and harness
properly, and turn on the power.
If Yes
Is F901normal? => NO =>
LINE_FILTER_UNIT: Isn't L901,L902,RV901,C903,C904,C901,C902, etc. out of order?
Moreover, whether the short-circuit with the circumference circuit is checked.
POWER_UNIT: BD901, RV902, IC951, etc.
out of order? Moreover, whether the short-circuit with the circumference circuit
is checked.
If Yes
Is BD901 (+320V) output? (Set the
main power SW to OFF.) * When power on/off switch is on -> About +400V => NO => Does the PFC circuit operate normally? (L906,
Q901, D902, D903, IC901 and etc. And, the circuit around the protection circuit
etc. is checked.)
If Yes
Is a voltage of +5V applied to pin
(11,12) of connector (CN902)?
(Set the main power SW to OFF.) =>
NO => Does the switching circuit operate normally? Check circuit around the
primary side (T901, IC931, Q931, ZD981, ZD930, D980, D981, ZD981, etc.), the
secondary side (D935, L980, etc.), the AC_DET circuit (ZD982, IC932, IC982,
Q992, Q993, etc.), and the protection circuit.
If Yes
Are +24V output as for the power
on/off switch when it is on? => No => Does the inverter circuit operate
normally? Check circuit around the primary side (T902,Q951,Q952,IC951,
D951,D952, etc.), the secondary side
(D955, L971, ZD967, IC952, IC953, etc.), the STANDBY circuit (Q988, etc.), and
the protection circuit.
If Yes
No comments:
Post a Comment