Sunday, January 10, 2016
Grundig LXW 102-8735 Cinemo 40 – 40 inch LCD TV – SMPS Circuit Diagram
Professional technician for all kind of electronic equipment. Doing since 1974.
Saturday, January 09, 2016
How to enter Service Mode - Adjustments - Zenith C27A25 – C36A26
Zenith C27A25, C27A25T6, C32A26, C32A26T6, C36A26, C36A26-8, C36A26T6,
C36A26T6-8
FACTORY MENU (Service Mode menu) ADJUSTMENTS
To access the Factory Menu, press and hold the MENU key until the User Menu display disappears, then press 9876, and then ENTER.
To access the Factory Menu, press and hold the MENU key until the User Menu display disappears, then press 9876, and then ENTER.
The black bar near the top of the screen indicates the part
number of the software in the TV set. To the lower right is a number indicating
that the module has been tested. The date on the black bar near the bottom left
of the screen indicates the date the module went through the factory.
When the Factory Menu appears, it displays the fourth Factory
Menu item: VERT POS. Use the SELECT UP/DOWN keys to toggle through all of the
adjustments. Uses ADJUST to make a change to the selected item.
00 FACT MENU: Use SELECT UP
and DOWN Keys to select item 00, the Factory Mode. The Factory uses this item
when the module is being tested. It has two positions: 0 and 1. In the field,
this item should always be left off (Zero is off).
When this item is off, only the first seven items in the Factory Menu can be accessed. They appear one at a time near the middle left of the screen. When this item is set to 1, 59 menu items are available. In the Factory Menu, only the selected menu item is displayed, near the top of the screen, as shown in the figure.
When this item is off, only the first seven items in the Factory Menu can be accessed. They appear one at a time near the middle left of the screen. When this item is set to 1, 59 menu items are available. In the Factory Menu, only the selected menu item is displayed, near the top of the screen, as shown in the figure.
When the Factory Menu is on, the AC Power-On feature is always
enabled regardless of the setting of AC ON in the Factory Menu. The TV set will
automatically come on when AC is applied.
Use the remote to reenter the Factory Menu to turn the Factory Menu off.
Setting the clock or running the Auto Program feature in the customer Set Up
menu can also turn off the Factory Mode.
01 PRESET PX: Stores customer
menu adjustments in the nonvolatile memory of the EAROM. Selections are Custom
and Preset-Store. Settings for Contrast, Brightness, Color and Tint are stored
in this manner. 0 is custom and 1 is Preset stored.
02 VERT P0S: Moves On-Screen
Displays vertically. The Range is from 0-30. This adjustment is generally set
at 15.
03 H0RZ POS: Moves On-Screen Displays horizontally. Range is from 1-45. Generally set at 20.
04 FEATURE LEVEL: There are three positions: 0,1 and 2.The three positions are used at the factory to program the module for the correct features. In order to change the level, short pins 3 and 4 togather on connector 4G9 on the main module.
03 H0RZ POS: Moves On-Screen Displays horizontally. Range is from 1-45. Generally set at 20.
04 FEATURE LEVEL: There are three positions: 0,1 and 2.The three positions are used at the factory to program the module for the correct features. In order to change the level, short pins 3 and 4 togather on connector 4G9 on the main module.
NOTE: BE CAREFUL! IF THE WRONG PINS
ARE SHORTED, THE MODULE CAN BE DAMAGED.
BE SURE TO REMOVE THE JUMPER AFTER THE LEVEL HAS BEEN SET.
Level 0 is used for private label sets. Levels 1 and 2 are used for Zenith sets.
05 BAND: There are eight positions.
0 is Broadcast fixed 4 is Broadcast afc.
1 is CATV afc 5 is CATV fixed
2 is HRC afc 6 is HRC fixed
3 is ICC afc 7 is ICC fixed
Level 0 is used for private label sets. Levels 1 and 2 are used for Zenith sets.
05 BAND: There are eight positions.
0 is Broadcast fixed 4 is Broadcast afc.
1 is CATV afc 5 is CATV fixed
2 is HRC afc 6 is HRC fixed
3 is ICC afc 7 is ICC fixed
06 POWER ONLY: There are two
positions, 0 is off and 1 is AC on. In position 1 the unit will turn on and off
when AC power is applied and removed.
07 RF SUB BRT: (RF brightness) Sets adjustment range of customer control for brightness in RF mode. Range is 0-63. A typical value is 32.
08 AUX SUB BRT: (Auxiliary Brightness) Sets adjustment range of the customer control for brightness in AUX mode. Range is 0-63. Typical value is 32.
07 RF SUB BRT: (RF brightness) Sets adjustment range of customer control for brightness in RF mode. Range is 0-63. A typical value is 32.
08 AUX SUB BRT: (Auxiliary Brightness) Sets adjustment range of the customer control for brightness in AUX mode. Range is 0-63. Typical value is 32.
09 MAX CONTRAST: Sets adjustment
range of customer control for contrast. Range is 0-63. Typical value is 63.
10 VERT SIZE: (Vertical Size) Range is 0-254.
11 HORZ SIZE: (Horizontal Size) Range is 0-254.
12 VERT PHASE: (Vertical Phase) Shifts picture vertically. Range is 0-7.
10 VERT SIZE: (Vertical Size) Range is 0-254.
11 HORZ SIZE: (Horizontal Size) Range is 0-254.
12 VERT PHASE: (Vertical Phase) Shifts picture vertically. Range is 0-7.
13 HORZ PHASE: (Horizontal
Phase) Shifts picture horizontally. Range is from 0-30.
14 HORZ AFC: Fast/slow response. Horizontal frequency control. Range is 0-1.
15 BAND PASS: Sets use of ICX2200’s internal band pass chrome filter. Range is 0-1. Set to 1.
16 TRAP 3.58: Zero is off, one is on. Set to 1 for normal TV operation. Set to 0 if Y/C is used or chassis has a comb filter.
14 HORZ AFC: Fast/slow response. Horizontal frequency control. Range is 0-1.
15 BAND PASS: Sets use of ICX2200’s internal band pass chrome filter. Range is 0-1. Set to 1.
16 TRAP 3.58: Zero is off, one is on. Set to 1 for normal TV operation. Set to 0 if Y/C is used or chassis has a comb filter.
17 RED CUT: B&W tracking
adjustment. Range is 0 to 254. Typical value is 0.
18 GREEN CUT: B&W tracking adjustment. Range is 0- 254. Typical value is 0.
19 BLUE CUT: B&W tracking adjustment. Range is 0-254. Typical value is 0.
20 GREEN GAIN: B&W tracking adjustment. Range is 0- 255. Typical value is 144.
21 BLUE GAIN: B&W tracking adjustment. Range is 0-254. Typical value is 144.
22 60HZ SW: (60 Hertz Switched) The range is 0 to 2. Set to 2.
23 WHITE COMPRESS: (White Compression) The range is 0 to 1. Set to 1. 0 = Enable and 1 = Disable.
18 GREEN CUT: B&W tracking adjustment. Range is 0- 254. Typical value is 0.
19 BLUE CUT: B&W tracking adjustment. Range is 0-254. Typical value is 0.
20 GREEN GAIN: B&W tracking adjustment. Range is 0- 255. Typical value is 144.
21 BLUE GAIN: B&W tracking adjustment. Range is 0-254. Typical value is 144.
22 60HZ SW: (60 Hertz Switched) The range is 0 to 2. Set to 2.
23 WHITE COMPRESS: (White Compression) The range is 0 to 1. Set to 1. 0 = Enable and 1 = Disable.
24 6 KEY SYSTEM: Keyboard type.
Set to 1 for 6 key and 0 for 10 key.
25 FRONT JACK: 1 = enabled, 0 = disabled
26 XTAL SELECT: Select the xtal oscillator for OSD. Range is 0-1
27 SOUND ATT: Composite audio level adjustment. Range is 0 -63.
28 SOUND ATT2: Composite audio level adjustment for tuner 2. Range is 0 -63.
29 RF AGC: (Rf Automatic Gain Control) Range is from 0-63. 48 is a general setting. Tune in weakest available channel and adjust for a snow- free picture.
30 PIF VCO: Range is 0-127. 70 are typical.
25 FRONT JACK: 1 = enabled, 0 = disabled
26 XTAL SELECT: Select the xtal oscillator for OSD. Range is 0-1
27 SOUND ATT: Composite audio level adjustment. Range is 0 -63.
28 SOUND ATT2: Composite audio level adjustment for tuner 2. Range is 0 -63.
29 RF AGC: (Rf Automatic Gain Control) Range is from 0-63. 48 is a general setting. Tune in weakest available channel and adjust for a snow- free picture.
30 PIF VCO: Range is 0-127. 70 are typical.
31 AUDIO ATT: Audio Attenuator
for main tuner. Range is 0-15. 9 is typical.
32 AUDIO VCO: Audio voltage controlled oscillator. Range is 0 -63. 31 is typical.
33 AUDIO FILTER: (Second Audio Program Voltage-Controlled Oscillator) Stereo, SAP, and dBx filter adjustment. Range is from 0-63.
34 AUDIO SPECTRL: Adjustment of stereo separation (3kHz). Range is 0-63.
35 WIDE BAND: Adjustment of stereo separation (300kHz). Range is 0-63.
36 DELAY PIP SELECT: Delay of output signal. Range is 0 -15. Typical is 15.
32 AUDIO VCO: Audio voltage controlled oscillator. Range is 0 -63. 31 is typical.
33 AUDIO FILTER: (Second Audio Program Voltage-Controlled Oscillator) Stereo, SAP, and dBx filter adjustment. Range is from 0-63.
34 AUDIO SPECTRL: Adjustment of stereo separation (3kHz). Range is 0-63.
35 WIDE BAND: Adjustment of stereo separation (300kHz). Range is 0-63.
36 DELAY PIP SELECT: Delay of output signal. Range is 0 -15. Typical is 15.
37 PIP V LEV: PIP auto gain
control. Range is 0 - 15 . Typical is 14.
38 YOFSET: PIP luminance offset. Range is 0 - 3. Typical is 0.
39 PIP PLLITC: PIP PLL synchronization. Range is 0 - 3. Typical is 0.
40 PIP HFP: PIP horizontal fine position. Range is 0 - 31. Typical is 0.
41 PIP INCRA: PIP Regenerated Color Carrier Frequency. Range is 0 - 31. Typical is 15.
42 PIP RED CUTOFF: Adjustment of blanking level. Range is 0 - 15. Typical is 0.
43 PIP GREEN CUTOFF: Adjustment of blanking level. Range is 0 - 15. Typical is 0.
44 PIP BLUE CUTOFF: Adjustment of blanking level. Range is 0 - 15. Typical is 0.
45 PIP COLOR FRAME: Range is 0 - 63. Typical is 16.
46 PIP FR WID H: PIP Horizontal width of frame. Range is 0 - 7. Typical is 1.
47 PIP FR WID V: PIP Vertical size of frame. Range is 0 - 3. Typical is 0.
48 PIP C KILL: PIP Color Killer threshold. Range is 0 - 3. Typical is 2.
49 PIP Y PEAK: PIP Luminance peaking. Range is 0 - 7. Typical is 4.
50 PIP R GAIN: PIP Red Amplitude. Range is 0 - 254. Typical is 190.
51 PIP G GAIN: PIP Green Amplitude. Range is 0 - 254. Typical is 190.
52 PIP B GAIN: PIP Blue Amplitude. Range is 0 - 254. Typical is 190.
53 PIP COLOR ON: PIP Color on/off. Range is 0 - 1. Typical is 0.
54 PIP FRAME SEL: 3D PIP Frame Selection. Range is 0 - 1. Typical is 1.
55 PIP X1 POSITION: Range is 0 - 127.
56 PIP Y1 POSITION: Range is 0 - 254.
57 PIP X2 POSITION: Range is 0 - 127.
58 PIP Y2 POSITION: Range is 0 - 254.
38 YOFSET: PIP luminance offset. Range is 0 - 3. Typical is 0.
39 PIP PLLITC: PIP PLL synchronization. Range is 0 - 3. Typical is 0.
40 PIP HFP: PIP horizontal fine position. Range is 0 - 31. Typical is 0.
41 PIP INCRA: PIP Regenerated Color Carrier Frequency. Range is 0 - 31. Typical is 15.
42 PIP RED CUTOFF: Adjustment of blanking level. Range is 0 - 15. Typical is 0.
43 PIP GREEN CUTOFF: Adjustment of blanking level. Range is 0 - 15. Typical is 0.
44 PIP BLUE CUTOFF: Adjustment of blanking level. Range is 0 - 15. Typical is 0.
45 PIP COLOR FRAME: Range is 0 - 63. Typical is 16.
46 PIP FR WID H: PIP Horizontal width of frame. Range is 0 - 7. Typical is 1.
47 PIP FR WID V: PIP Vertical size of frame. Range is 0 - 3. Typical is 0.
48 PIP C KILL: PIP Color Killer threshold. Range is 0 - 3. Typical is 2.
49 PIP Y PEAK: PIP Luminance peaking. Range is 0 - 7. Typical is 4.
50 PIP R GAIN: PIP Red Amplitude. Range is 0 - 254. Typical is 190.
51 PIP G GAIN: PIP Green Amplitude. Range is 0 - 254. Typical is 190.
52 PIP B GAIN: PIP Blue Amplitude. Range is 0 - 254. Typical is 190.
53 PIP COLOR ON: PIP Color on/off. Range is 0 - 1. Typical is 0.
54 PIP FRAME SEL: 3D PIP Frame Selection. Range is 0 - 1. Typical is 1.
55 PIP X1 POSITION: Range is 0 - 127.
56 PIP Y1 POSITION: Range is 0 - 254.
57 PIP X2 POSITION: Range is 0 - 127.
58 PIP Y2 POSITION: Range is 0 - 254.
SMPS SCHEMATIC
HORIZONTAL & VERTICAL SCAN OUT
Click on the pictures to Magnify
Professional technician for all kind of electronic equipment. Doing since 1974.
Thursday, January 07, 2016
LG LIPS37 – LCD TV SMPS – Schematic
Professional technician for all kind of electronic equipment. Doing since 1974.
Tuesday, January 05, 2016
How to enter Service Mode – Philips 32PFL3508 – 32 inch LCD TV - Firmware Update
Service Mode – Initialization - Power (SMPS) and Audio amplifier
circuit diagram
TYPE A
32PFL3508/F7 PHILIPS (Serial No.: ME1) - 32PFL3508/F8 PHILIPS (Serial No.: XA1, XA2) - 32PFL1508/F8 PHILIPS (Serial No.: XA1)
TYPE B
32PFL1508/F8 PHILIPS (Serial No.: DS1)
32PFL1508/F8 PHILIPS (Serial No.: DS1)
Power
Supply Schematic Diagram [TYPE A]
Fixed voltage (or Auto
voltage selectable) power supply circuit is used in this unit. If Main Fuse (F602) is blown , check to see
that all components in the power supply circuit are not defective before you
connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to
fail.
Power
Supply Schematic Diagram [TYPE B]
Audio Output
How to set up the service mode
Service mode:
1. Turn the power on.
2. Press [MENU] button to display Setup menu.
3. Select “Features”.
4. Select “Software Upgrade”.
5. Select “Current Software Info”.
6. Press [0], [6], [2], [5], [9], [6] and [INFO] buttons on the remote control unit in this order. The following screen appears.
Service mode:
1. Turn the power on.
2. Press [MENU] button to display Setup menu.
3. Select “Features”.
4. Select “Software Upgrade”.
5. Select “Current Software Info”.
6. Press [0], [6], [2], [5], [9], [6] and [INFO] buttons on the remote control unit in this order. The following screen appears.
HOW TO INITIALIZE THE LCD TV
The purpose of initialization is to place the set in a new out of box
condition. The customer will be prompted to select a language and program
channels after the set has been initialized.
To put the program back at the factory-default, initialize the LCD TV using the following procedure.
NOTE: Disconnect any device from the USB Port before you conduct on this procedure.
1. Turn the power on.
2. Enter the service mode. To cancel the service mode, press [the Power ] button on the remote control unit.
3. Press [BACK] button to enter the Panel Key Confirmation Menu.
4. Press any button on the control panel.
5. Press [INFO] button to proceed with the self check mode.
6. Make sure to confirm the “INITIALIZED FINISH” appears in the green screen.
7. Unplug the AC Cord and plug it back on again.
To put the program back at the factory-default, initialize the LCD TV using the following procedure.
NOTE: Disconnect any device from the USB Port before you conduct on this procedure.
1. Turn the power on.
2. Enter the service mode. To cancel the service mode, press [the Power ] button on the remote control unit.
3. Press [BACK] button to enter the Panel Key Confirmation Menu.
4. Press any button on the control panel.
5. Press [INFO] button to proceed with the self check mode.
6. Make sure to confirm the “INITIALIZED FINISH” appears in the green screen.
7. Unplug the AC Cord and plug it back on again.
FIRMWARE RENEWAL MODE
Firmware Update Procedure
User Upgrade (Filename example: TVNB012_00_PF_XX91_AC.ecc)
Upgrade the firmware only. The setting values will not be initialized.
The User Upgrade and the Firmware Upgrade (Factory Upgrade) will be done by the same file. If you want to upgrade the firmware and initialize the setting values also, add “FACT_” at the beginning of the filename. If you want to upgrade the firmware only and leave the setting values as they are, eliminate the “FACT_” from the filename.
User Upgrade (Filename example: TVNB012_00_PF_XX91_AC.ecc)
Upgrade the firmware only. The setting values will not be initialized.
The User Upgrade and the Firmware Upgrade (Factory Upgrade) will be done by the same file. If you want to upgrade the firmware and initialize the setting values also, add “FACT_” at the beginning of the filename. If you want to upgrade the firmware only and leave the setting values as they are, eliminate the “FACT_” from the filename.
Update procedure
1. Turn the power on.
2. Press [MENU] button to display Menu.
3. Select “Features”.
4. Select “Software Upgrade”.
5. Select “Upgrade” to display Upgrade screen.
6. Press [OK] button to display Software Upgrade screen.
7. Select “USB” and press [OK] button.
8. Insert the USB storage device to the USB port.
9. Select “Check” and press [OK] button.1. Turn the power on.
2. Press [MENU] button to display Menu.
3. Select “Features”.
4. Select “Software Upgrade”.
5. Select “Upgrade” to display Upgrade screen.
6. Press [OK] button to display Software Upgrade screen.
7. Select “USB” and press [OK] button.
8. Insert the USB storage device to the USB port.
10. Select “Upgrade” and press [OK] button to start software upgrade.
Factory Upgrade (Firmware Upgrade/Flash
Upgrade)
Firmware Upgrade (Filename example: FACT_TVNB012_00_PF_XX91_AC.ecc)
Upgrade the firmware and initialize the setting values.
The User Upgrade and the Firmware Upgrade (Factory Upgrade) will be done by the same file. If you want to upgrade the firmware and initialize the setting values also, add “FACT_” at the beginning of the filename. If you want to upgrade the firmware only and leave the setting values as they are, eliminate the “FACT_” from the filename.
Flash Upgrade (Filename example: ALL_TVNB012_00_PF_XX91_AC.ecc)
Upgrade the firmware and initialize the setting values along with the factory default such as White Balance, etc.
Before the upgrade, you will need to make a note of all the factory default so you will be able to set it back on the TV after the initialization.
The Flash Upgrade will be done by it's unique file.
The User Upgrade/Firmware Upgrade (Factory Upgrade) file cannot be used for this upgrade.
Firmware Upgrade (Filename example: FACT_TVNB012_00_PF_XX91_AC.ecc)
Upgrade the firmware and initialize the setting values.
The User Upgrade and the Firmware Upgrade (Factory Upgrade) will be done by the same file. If you want to upgrade the firmware and initialize the setting values also, add “FACT_” at the beginning of the filename. If you want to upgrade the firmware only and leave the setting values as they are, eliminate the “FACT_” from the filename.
Flash Upgrade (Filename example: ALL_TVNB012_00_PF_XX91_AC.ecc)
Upgrade the firmware and initialize the setting values along with the factory default such as White Balance, etc.
Before the upgrade, you will need to make a note of all the factory default so you will be able to set it back on the TV after the initialization.
The Flash Upgrade will be done by it's unique file.
The User Upgrade/Firmware Upgrade (Factory Upgrade) file cannot be used for this upgrade.
Update procedure
1. Turn the power off.
2. Insert the USB storage device to the USB port.
1. Turn the power off.
2. Insert the USB storage device to the USB port.
3. Turn the power on.
4. The update will start and the following will appear in the screen.
4. The update will start and the following will appear in the screen.
If the screen isn't displayed, repeat
from step 1.
5. When the firmware update is
completed; completion screen will appear.
Remove the USB storage device from
the USB port.
Turn the power off and turn the power on again.
Service mode initial screen with a word “INITIALIZED” will appear in the screen. The colour of the word “INITIALIZED” will change from red to green when initialization is completed.
Turn the power off and turn the power on again.
Service mode initial screen with a word “INITIALIZED” will appear in the screen. The colour of the word “INITIALIZED” will change from red to green when initialization is completed.
CLICK ON THE PICTURES TO MAGNIFY
Professional technician for all kind of electronic equipment. Doing since 1974.
Sharp LC-65RX1H LC-65RX1X LCD COLOR TELEVISION - Service mode – Software update – Error codes – Hotel Mode
How
to enter Service Mode – Hotel Mode – Lamp Reset – Firmware Upgrade - Error Codes - Lamp Error Detection - Sharp LC65RX1H - Sharp LC65RX1X - LCD TVs
Entering and exiting the adjustment
process mode1 Press the “POWER” key on the set of running TV set to force off the power.
2 While holding down the “VOL (-)” and “TV/VIDEO” keys on the set at once, press the “POWER” key on the set to turn on the power. The letter “K” appears on the screen.
3 Next, hold down the “VOL (-)” and “CH ( )” keys on the set at once. Multiple lines of character string appearing on the screen indicate that the set is now in the adjustment Process mode. If you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure. (Another procedure)
4 Press the “MENU” key on the main unit to display OSD.
5 Move the cursor to SERVICE (OSD) using the cursor keys on the remote control. Then press the “MENU” key on the remote control to enter the service mode (adjustment process mode).
6 To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off the power. (When the power is turned off with the remote controller, once unplug the AC power cord and plug it in again. In this case, wait 10 seconds or so before plugging.)
[Use due care in handling
the information described here lest the users should know how to enter the
adjustment process mode. If the settings are tampered with in this mode,
unrecoverable system damage may result.]
Remote controller key operation and
description of display in adjustment process mode.
> CH (/) - CH (Up /Dn ):
Moving an item (line) by one (UP/DOWN)
> VOL (+/-): VOL (+/-): Changing a selected item setting (+1/-1)
> Cursor (Up /Dn ) : Turning a page (PREVIOUS / NEXT)
> Cursor (L /R ): Changing a selected line setting (+10/-10)
> TV/VIDEO on remote controller:
Input source switching (toggle switching) (TV→EXT1~8)
> RETURN: Returning to a present page.
> ENTER: Executing a
function.
Input mode is switched automatically when relevant adjustment is
started so far as the necessary input signal is available.
Description of display
Lamp error detection
Function
This LCD color TV set incorporates a lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some reason, the following will result.
* The power is interrupted in about 6 seconds after it is turned on. (The power LED on the front of the TV set turns red from green and keeps blinking in red: ON for 250 ms and OFF for 1 sec.).
* If the above phenomenon 1) occurs 5 times consecutively, it becomes impossible to turn on the power. (The power LED remained red).
Function
This LCD color TV set incorporates a lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some reason, the following will result.
* The power is interrupted in about 6 seconds after it is turned on. (The power LED on the front of the TV set turns red from green and keeps blinking in red: ON for 250 ms and OFF for 1 sec.).
* If the above phenomenon 1) occurs 5 times consecutively, it becomes impossible to turn on the power. (The power LED remained red).
Measures
Checking with lamp error detection OFF
Enter the adjustment process mode, referring to 1. Entering and exiting the adjustment process mode. If there is a problem with the lamp or lamp circuit, the lamp will go out. (The power LED is green.) Then, you can check the operation to see if the lamp and lamp circuit are in trouble.
Resetting the lamp error count
After the lamp and lamp circuit are found out of trouble, reset the lamp error count. If a lamp error is detected five consecutive times, the power cannot be turned on. Using the cursor (UP/DOWN) key, move to the cursor to [LAMP ERROR RESET], Line 8 on adjustment process mode service page 2/33. With the cursor (LEFT/RIGHT) keys, select the [LAMP ERROR RESET] value. Finally press the cursor (ENTER) keys to reset the value to “0”.
Checking with lamp error detection OFF
Enter the adjustment process mode, referring to 1. Entering and exiting the adjustment process mode. If there is a problem with the lamp or lamp circuit, the lamp will go out. (The power LED is green.) Then, you can check the operation to see if the lamp and lamp circuit are in trouble.
Resetting the lamp error count
After the lamp and lamp circuit are found out of trouble, reset the lamp error count. If a lamp error is detected five consecutive times, the power cannot be turned on. Using the cursor (UP/DOWN) key, move to the cursor to [LAMP ERROR RESET], Line 8 on adjustment process mode service page 2/33. With the cursor (LEFT/RIGHT) keys, select the [LAMP ERROR RESET] value. Finally press the cursor (ENTER) keys to reset the value to “0”.
STANDBY CAUSE FUNCTIONS
This model is equipped with a STANDBY CAUSE FUNCTIONS which stores the cause of why the unit is turned off and displays it on adjustment process mode.
NORMAL STANDBY CAUSE
ERROR CODE here indicates cause of standby in normal operation or Function of the Unit.
No display when the unit is turned off with R/C.
Only the latest cause is indicated.
ERROR STANDBY CAUSE
ERROR CODE here indicates cause of Error in the unit.
It also indicates accumulated operating times of the unit.
The last five histories are displayed.
1)-5) five histories 1) is the latest.
When there is no error, error code is ‘0’ and no characters appear.
This model is equipped with a STANDBY CAUSE FUNCTIONS which stores the cause of why the unit is turned off and displays it on adjustment process mode.
NORMAL STANDBY CAUSE
ERROR CODE here indicates cause of standby in normal operation or Function of the Unit.
No display when the unit is turned off with R/C.
Only the latest cause is indicated.
ERROR STANDBY CAUSE
ERROR CODE here indicates cause of Error in the unit.
It also indicates accumulated operating times of the unit.
The last five histories are displayed.
1)-5) five histories 1) is the latest.
When there is no error, error code is ‘0’ and no characters appear.
MONITOR ERROR CAUSE
When the monitor micom detects an error, ERROR CODE is displayed.
The number of flashing Power LED and OPC LED indicates location of error detected.
This number stores the latest four contents of the error. ‘0’ is displayed when no error.
When the monitor micom detects an error, ERROR CODE is displayed.
The number of flashing Power LED and OPC LED indicates location of error detected.
This number stores the latest four contents of the error. ‘0’ is displayed when no error.
Public Mode (Hotel Mode)
1. Starting the Public Mode
There are two following ways to display the PUBLIC Mode setting screen.
1 On the process adjustment mode screen (2/32), set the “HOTEL MODE” Flag to ON. Turn off the power, and turn it on again, pressing the and keys of the main unit at the same time.
2 Enter the Pass Word, and start the unit.
a Turn on the power, pressing the and keys of the main unit at the same time.
b Display the Pass Word input screen.
1. Starting the Public Mode
There are two following ways to display the PUBLIC Mode setting screen.
1 On the process adjustment mode screen (2/32), set the “HOTEL MODE” Flag to ON. Turn off the power, and turn it on again, pressing the and keys of the main unit at the same time.
2 Enter the Pass Word, and start the unit.
a Turn on the power, pressing the and keys of the main unit at the same time.
b Display the Pass Word input screen.
Operation procedure
The initial input position is the digit at the left end.
For the numeric keys to of R/C, key input is accepted. Input of the other keys is prohibited.
Change “-” to “*” by inputting the numeric key at the input position, and shift the input position rightward one digit.
When three digits are completely input, the Pass Word is judged.
c Check the Pass Word by inputting three digits.
If the Pass Word is[0] [2] [7] , it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
The initial input position is the digit at the left end.
For the numeric keys to of R/C, key input is accepted. Input of the other keys is prohibited.
Change “-” to “*” by inputting the numeric key at the input position, and shift the input position rightward one digit.
When three digits are completely input, the Pass Word is judged.
c Check the Pass Word by inputting three digits.
If the Pass Word is[0] [2] [7] , it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
Exiting the Public Mode screen
There are two following ways to exit the Public Mode setting screen.
1 Turn off the power.
2 Select “Execution” in the PUBLIC_Mode to execute it. Activate the restart under the set content. Here, the START input SOURCE setting is excluded since this item is referred to only when the power is turned on.
3. Set value of the Public Mode
Each set value in the PUBLIC Mode is initialized when the factory setting is applied. (The setting of the PUBLIC MODE Flag in the process adjustment mode screen is not changed.)
There are two following ways to exit the Public Mode setting screen.
1 Turn off the power.
2 Select “Execution” in the PUBLIC_Mode to execute it. Activate the restart under the set content. Here, the START input SOURCE setting is excluded since this item is referred to only when the power is turned on.
3. Set value of the Public Mode
Each set value in the PUBLIC Mode is initialized when the factory setting is applied. (The setting of the PUBLIC MODE Flag in the process adjustment mode screen is not changed.)
Basic operation in the Public Mode
> Volume +/- or Cursor L/R:
Change or execution of the set value.
> Channel Up/Dn or Cursor Up /Dn: Movement to the selected item.
> Decision (ENTER): Execution
(Used by the items “Execution” and “RESET”.
> PUBLIC Mode R/C: Ordinary
operation mode: It enters the PUBLIC Mode.
PUBLIC MODE Flag is set to “ON”.
> PUBLIC Mode: It exits the PUBLIC Mode. PUBLIC MODE Flag does not
change. Any set item in PUBLIC Mode is
not initialized.
Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
The set contents in the PUBLIC mode are initialized.
It does not exit the PUBLIC mode.
PUBLIC MODE Flag does not change. (It is not set to OFF.)
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
The set contents in the PUBLIC mode are initialized.
It does not exit the PUBLIC mode.
PUBLIC MODE Flag does not change. (It is not set to OFF.)
Upgrading the software
> Turn off the AC power (Unplug the AC power cord).
> Insert the upgrading USB flash memory for upgrade into the service slot.
> While holding down the power button, plug in the AC power cord of the main unit to turn on the power.
> Upgrade begins automatically. After the set starts, the upgrade screen appears.
> Turn off the AC power (Unplug the AC power cord).
> Insert the upgrading USB flash memory for upgrade into the service slot.
> While holding down the power button, plug in the AC power cord of the main unit to turn on the power.
> Upgrade begins automatically. After the set starts, the upgrade screen appears.
If any of the procedures fails, the following upgrade failure
screen shows up. For the failing procedure, the “NG” marking turns red. NOTE: In such case, try to upgrade the
software again. If it still fails, the hardware may be in trouble.
> When all the procedures are complete, the following upgrade
success screen shows up. The new software version can be confirmed on screen. The version number appears when each item has been successfully upgraded.
Finally the main version number appears on screen.
> Turn off the AC power (Unplug the AC power cord). Take out the
upgrading USB flash memory.
Now the software has been upgraded.
NOTE: Then get the set started and call the process adjustment screen 1/32 to check the main software version.
CAUTION
1 Do not take out and put in the USB flash memory during formatting.
2 It takes about one minute to the rewriting completion.
Confirm the upgrade status on the screen becomes 100%.
Now the software has been upgraded.
NOTE: Then get the set started and call the process adjustment screen 1/32 to check the main software version.
CAUTION
1 Do not take out and put in the USB flash memory during formatting.
2 It takes about one minute to the rewriting completion.
Confirm the upgrade status on the screen becomes 100%.
[A normal user is not supposed to do any repair work to the circuit part of this set; as it need sophisticated testing equipments, and proper knowledge to follow. Contact any experienced service technician; or the authorized service centre for Sharp, in case any such incident occurs.]
Professional technician for all kind of electronic equipment. Doing since 1974.
A715G5793 - Philips LED LCD TV - SMPS - Circuit Diagram
Professional technician for all kind of electronic equipment. Doing since 1974.
Saturday, January 02, 2016
Colour TV Circuit Diagram - TMPA8873KPANG6HV9 - syscon-chroma IC
Used ICs - TMPA8873KPANG6HV9 – 24C08 – AN17821M – TA1343 – 78041-
BSC-29-D122Z(LOT) – TC4053 – KA5Q0765STR
SMPSTMPA8873
FULL SCHEMATIC
CLICK ON THE PICTURES TO ZOOM IN
Professional technician for all kind of electronic equipment. Doing since 1974.
Friday, January 01, 2016
Daewoo LCD TV Troubleshooting - Software Upgrade - Service Mode
Daewoo LA32L1B1LM - LA37L1B1LM - LA42L1B1LM - LA42L1B1LF
LCD TV does not response or remote controller does not work.
- Check the power cord to be plugged.
- Check the battery of the remote controller.
Sound
is discontinuous or broken sometimes.- Check the power cord to be plugged.
- Check the battery of the remote controller.
- Check if [SOUND] -> [AVC] is [ON].
- Set the sound effect into 'F Mono'?
- Set the [SOUND] -> [Digital Volume] into proper value.
- [Digital Volume] is enabled only in digital program.
- Check if [SOUND] -> [Speaker] is On.
Picture of digital program is sometimes broken and sound is discontinuous.
- Digital program has a little problem because of signal receiving status.
- Check if the RF cable is correctly connected.
- Ask for the broadcasting station if the RF cable connection has no problem.
Picture of analog program is noisy.
- Check the RF cable connection.
- Check if [Picture] -> [N.R] is ON.
- Change the [Channel] -> [Fine Tune] value.
Sound is not generated in HDMI mode.
- Reconnect HDMI jack.
- DVI signal has no sound. Check the output signal of device to be connected to LCD TV.
- If you want to use DVI-HDMI cable, you should also connect audio cable into the LCD TV.
In spite of 'Auto Setup', picture size is not completely adapted to the screen in PC mode.
- Check if the input signal is available.
- Ensure that the desktop has no black area.
- Some errors (picture position problem) will be occurred according to certain video card. In this case, you should adjust ‘Phase’, ‘Clock’, ‘H.Position’, ‘V.Position’ control.
In spite of 'Auto Setup', picture is not clear in the PC mode.
- Adjust 'Phase' control.
- Check if [Picture] -> [N.R] is ON.
- Change the [Channel] -> [Fine Tune] value.
Sound is not generated in HDMI mode.
- Reconnect HDMI jack.
- DVI signal has no sound. Check the output signal of device to be connected to LCD TV.
- If you want to use DVI-HDMI cable, you should also connect audio cable into the LCD TV.
In spite of 'Auto Setup', picture size is not completely adapted to the screen in PC mode.
- Check if the input signal is available.
- Ensure that the desktop has no black area.
- Some errors (picture position problem) will be occurred according to certain video card. In this case, you should adjust ‘Phase’, ‘Clock’, ‘H.Position’, ‘V.Position’ control.
In spite of 'Auto Setup', picture is not clear in the PC mode.
- Adjust 'Phase' control.
1. When you connect with component, PC (D-Sub), and HDMI, you must
check the input resolution of external devices.
2. So if this mode is used at PC mode, the screen can be enlarged.
3. 1600x1200 & 1920x1080P modes are supported only Full HD model.
2. So if this mode is used at PC mode, the screen can be enlarged.
3. 1600x1200 & 1920x1080P modes are supported only Full HD model.
Closed Caption SPEC
DIGITAL(ATSC) standard inspection pattern : CC708 SPEC STREAM(release to GUMI factory : 2007.02.02)
The Caption feature doesn’t work in COMPONENT, HDMI, and PC modes.
The availability of captions depends on the program being broadcast.
Caption lables and respective meanings.
Analog (NTSC) : CC1 : The Primary Synchronous Caption Service.
These are captions in the primary language that must be in sync with the sound, preferably matched to a specific frame.
CC2 : The Special Non-Synchronous Use Captions.
This channel carries data that is intended to augment information carried in the program.
CC3 : Secondary Synchronous Caption Service.
Alternate program-related caption data, typically second language captions.
CC4 : Special Non-Synchronous Use Captions.
Similar to CC2.
DIGITAL(ATSC) standard inspection pattern : CC708 SPEC STREAM(release to GUMI factory : 2007.02.02)
The Caption feature doesn’t work in COMPONENT, HDMI, and PC modes.
The availability of captions depends on the program being broadcast.
Caption lables and respective meanings.
Analog (NTSC) : CC1 : The Primary Synchronous Caption Service.
These are captions in the primary language that must be in sync with the sound, preferably matched to a specific frame.
CC2 : The Special Non-Synchronous Use Captions.
This channel carries data that is intended to augment information carried in the program.
CC3 : Secondary Synchronous Caption Service.
Alternate program-related caption data, typically second language captions.
CC4 : Special Non-Synchronous Use Captions.
Similar to CC2.
Digital (ATSC) :
Service 1 : Primary Caption Service This service contains the verbatim, or near-verbatim captions for the primary language being spoken in the accompanying program audio.
Service 2 : Secondary Language Service.
This service contains caption in a secondary language which are translations of the captions in the Primary Caption Service.
The other service sub-channels are not pre-assigned.
It is up to discretion of the individual caption provider to utilize the remaining service channels.
Caption style
Default means to follow the standard set by the broadcaster.
Text Size : This option consists of Default,Small,Standard,and large.
The default is Standard.
Text Font : This option consists of Default,
Font 1~7.You can change the font you want.
Text Color : This option consists of Default, White, Black, Red, Green, Blue, Yellow, Magenta, and Cyan.
You can change the color of the letter.The default is White.
BG Color : This option consists of Default, White, Black, Red, Green, Blue, Yellow, Magenta, and Cyan. You can change the background color of the caption. The default is Black.
BG Opacity : This option consists of Default, Rich, Light, and Transparent. You can change the background opacity of the caption.
Service 1 : Primary Caption Service This service contains the verbatim, or near-verbatim captions for the primary language being spoken in the accompanying program audio.
Service 2 : Secondary Language Service.
This service contains caption in a secondary language which are translations of the captions in the Primary Caption Service.
The other service sub-channels are not pre-assigned.
It is up to discretion of the individual caption provider to utilize the remaining service channels.
Caption style
Default means to follow the standard set by the broadcaster.
Text Size : This option consists of Default,Small,Standard,and large.
The default is Standard.
Text Font : This option consists of Default,
Font 1~7.You can change the font you want.
Text Color : This option consists of Default, White, Black, Red, Green, Blue, Yellow, Magenta, and Cyan.
You can change the color of the letter.The default is White.
BG Color : This option consists of Default, White, Black, Red, Green, Blue, Yellow, Magenta, and Cyan. You can change the background color of the caption. The default is Black.
BG Opacity : This option consists of Default, Rich, Light, and Transparent. You can change the background opacity of the caption.
V Chip(Parental Control) SPEC
i) The rating doesn't work in PIP/POP mode. Reservse case is the same.
ii) The rating setting is possible only on the menu.
iii) Inital password : 2-2-1-1.
iv) Universal key cord (When user does not know password) : 5-4-2-2.
v) The TV Parental Guidelines.
Labels : TV-Y, TV-Y7, TV-G, TV-PG, and TV-14, TV-MA, FV, D, L, S, V
TV-Y : All Children. Program is designd to be appropriate for all children.
TV-Y7 : Directed to Older Children.
Program is designed for children age 7 and above.
TV-G : General Audience.
This Program contains material that parents may find suitable to younger children.
TV-PG : Parental Guidance Suggested.
This Program contains material that parents may find.
TV-14 : Parents Strongly Cautioned.
This Program contains some material that many parents wound find unsuitable for children less than 14 years of age.
TV-MA : Mature Audience Only.
This Program is specifically designd to be viewed by adults and therefore may be unsuitable for children under 17.
FV : Fantasy violence / D : Sexually Suggestive Dialog / L : Adult Language /
S : Sexual situation / V : Violence
vi) The Movie ratings
Labels : TV-Y, TV-Y7, TV-G, TV-PG, and TV-14, TV-MA, FV, D, L, S, V
G : General Audiences.All ages admitted.
PG : Parental Guidance Suggested.
Some material may not be suitable for children.
PG-13 : Parents Strongly Cautioned.
Some material may be inappropriate for children under 13.
R : Restricted.
Under 17 requires accompanying parent or adult guardian.
NC-17 : No children 17 and under admitted.
X : Adults only.
NR : Not rated.
i) The rating doesn't work in PIP/POP mode. Reservse case is the same.
ii) The rating setting is possible only on the menu.
iii) Inital password : 2-2-1-1.
iv) Universal key cord (When user does not know password) : 5-4-2-2.
v) The TV Parental Guidelines.
Labels : TV-Y, TV-Y7, TV-G, TV-PG, and TV-14, TV-MA, FV, D, L, S, V
TV-Y : All Children. Program is designd to be appropriate for all children.
TV-Y7 : Directed to Older Children.
Program is designed for children age 7 and above.
TV-G : General Audience.
This Program contains material that parents may find suitable to younger children.
TV-PG : Parental Guidance Suggested.
This Program contains material that parents may find.
TV-14 : Parents Strongly Cautioned.
This Program contains some material that many parents wound find unsuitable for children less than 14 years of age.
TV-MA : Mature Audience Only.
This Program is specifically designd to be viewed by adults and therefore may be unsuitable for children under 17.
FV : Fantasy violence / D : Sexually Suggestive Dialog / L : Adult Language /
S : Sexual situation / V : Violence
vi) The Movie ratings
Labels : TV-Y, TV-Y7, TV-G, TV-PG, and TV-14, TV-MA, FV, D, L, S, V
G : General Audiences.All ages admitted.
PG : Parental Guidance Suggested.
Some material may not be suitable for children.
PG-13 : Parents Strongly Cautioned.
Some material may be inappropriate for children under 13.
R : Restricted.
Under 17 requires accompanying parent or adult guardian.
NC-17 : No children 17 and under admitted.
X : Adults only.
NR : Not rated.
To enter SERVICE MODE,
A. Press “<VOL” -> “MUTE” -> “DISPLAY” -> “MUTE” button of remote controller(R-55M15)
B. Press “S9” button of SERVICE REMOTE CONTROLLER.
A. Press “<VOL” -> “MUTE” -> “DISPLAY” -> “MUTE” button of remote controller(R-55M15)
B. Press “S9” button of SERVICE REMOTE CONTROLLER.
When “No signal” in RF, AV1, AV2
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(RF) : CC220 near IC401(TOP)
-Main TP(AV1) : CC210 near IC202(TOP)
-Main TP(AV2) : CC212 near IC202(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(RF) : CC220 near IC401(TOP)
-Main TP(AV1) : CC210 near IC202(TOP)
-Main TP(AV2) : CC212 near IC202(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
When “No signal” in Y/C signal (S-Video)
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(S-Video_Y) : CC211 near IC202(TOP)
-Main TP(S-Video_C) : RC216 near IC202(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(S-Video_Y) : CC211 near IC202(TOP)
-Main TP(S-Video_C) : RC216 near IC202(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
When “No signal” in Y/Pb/Pr signal (Component)
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(COMP_Y) : RC238 near IC401(TOP)
-Main TP(COMP_Pb) : RC237 near IC401(TOP)
-Main TP(COMP_Pr) : RC239 near IC401(TOP)
=> If all signal does not appear, replace MAIN PCB.
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(COMP_Y) : RC238 near IC401(TOP)
-Main TP(COMP_Pb) : RC237 near IC401(TOP)
-Main TP(COMP_Pr) : RC239 near IC401(TOP)
=> If all signal does not appear, replace MAIN PCB.
No Picture-Digital TV mode
Check the IC path.
Tuner(TU101): LC111, CC156~158, RC104, RC105
STV0374(IC101): RA101~103, RC122
B+: 1V: (Pin10,34,35,42,53,58,68,78,89)
2.5V: (Pin14,18,19,28)
3.3V: (Pin49,67,80)
Tuner(TU101): LC111, CC156~158, RC104, RC105
STV0374(IC101): RA101~103, RC122
B+: 1V: (Pin10,34,35,42,53,58,68,78,89)
2.5V: (Pin14,18,19,28)
3.3V: (Pin49,67,80)
When “No signal” in PC
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(R signal) : RC239 near IC401(TOP)
-Main TP(G signal) : RC238 near IC202(TOP)
-Main TP(B signal) : RC237 near IC401(TOP)
-Main TP(H-Sync) : RC207 near JK203(TOP)
-Main TP(V-Sync) : RC206 near JK203(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(R signal) : RC239 near IC401(TOP)
-Main TP(G signal) : RC238 near IC202(TOP)
-Main TP(B signal) : RC237 near IC401(TOP)
-Main TP(H-Sync) : RC207 near JK203(TOP)
-Main TP(V-Sync) : RC206 near JK203(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
When “No signal” in HDMI
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(HDMI1_Clock) : PIN35 near IC201(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
1) First check if other inputs are not working
=>If other inputs are not working, replace MAIN PCB
2) Checking waveforms with Color Bar Pattern(Using the oscilloscope)
-Main TP(HDMI1_Clock) : PIN35 near IC201(TOP)
=>If all TP signal does not appear, replace MAIN PCB.
LCD PANEL BACK-LIGHT INVERTER CHECK
Pin 14 is Status Output of Back light Inverter.
Normal 3.0V to 5.0V
This model requires ‘dtv150_main.bin’ binary file and USB memory
for upgrade.
2. The upgrade file must be named dtv150_main.bin, and located in root directory in USB memory.
3. Press S9 button in service remote controller, and check the decoder version.
4. And move to ‘Dualboot Enable’ and select ‘On’ by pressing ‘¢∏/¢∫’ button.
5. Escape from service menu by pressing menu button.
6. Insert USB memory to USB slot on Side jack.
7. Turn off and on the TV set, then the TV set will be automatically upgraded.
2. The upgrade file must be named dtv150_main.bin, and located in root directory in USB memory.
3. Press S9 button in service remote controller, and check the decoder version.
4. And move to ‘Dualboot Enable’ and select ‘On’ by pressing ‘¢∏/¢∫’ button.
5. Escape from service menu by pressing menu button.
6. Insert USB memory to USB slot on Side jack.
7. Turn off and on the TV set, then the TV set will be automatically upgraded.
8. Upgrade time is about 2 minutes and the TV set will
automatically restart.
9. Press S9 button in service remote controller, and check the decoder version.
9. Press S9 button in service remote controller, and check the decoder version.
Professional technician for all kind of electronic equipment. Doing since 1974.