HITACHI PLASMA TV TROUBLESHOOTING (3)

Hitachi Plasma TV Troubleshooting
                                                                     {3}
FAULTS
  • The green power LED is always ON.
  • The  power LED will go green  and may go Off or stay ON.
  • Green power LED will go green then go Off or may not go green at all.
THE GREEN POWER LED IS ALWAYS ON
  • This indicates that the set is providing Vs and Va voltage to the X-SUSTAIN & Y-SUSTAIN PWBs.  Use an analogue scope.  Look at the outputs from X-SUS and X-BUS.  Use the top pin of the connector going to panel, on either side.  
  • No activity usually indcate with a defective PWB.
  • Pull the ribbon cable from that PWB  to the panel, and check again.
  • If there is activity now, the panel might be defective.  In most cases, it is.
  • Pull all ribbon connectors before condemning the PWB.
  • If the panel is defective, in most cases it can be seen by the panel itself.
  • If Top ribbon cable is pulled, the top of the screen will be black; but the bottom will have raster.
GREEN POWER LED GO GREEN THEN GO OFF.  
  • This indicates a load on the line.
  • Pull CN64 connector feeding Vs and Va voltages to X-Sustain.
  • Measure the resistance in [Ohms] from Va and Vs lines on each PWB.
  • Low resistance value indicates a defective PWB. Normal reading should be of Mega-ohms. Using the diode mode on the DV/Voltmeter, there should be a brief charge time, then infinity.  Note, if there is a charge on the line, the meter may show low.  Pull the CN-68 connector and take the reading again.
  • The line should now be infinity when reading the power supply pins for Va and Vs when reading the connector going to the X-SUSTAIN PWB.
  • If a low is see on the connector , pull CN32 [bottom right hand plug on the Y-SUS board.
After the connector is pulled:
If low disappears, then the Y-SUS or SDR PWB has the fault.  If low remains, X-SUSTAIN is faulty
Pull all ribbon cables going to the panel, one by one while reading Vs/Va pins.  If the low disappears, the panel is defective.  Before confirm, check SDR buffer too.
If low remains the Y-SUSTAIN and/or SDR PWBs are defective.

Will be continued on next post: