TOOLS NEEDED
- LCD/PDP TV Set.
- Update Cable (RS-232C to Stereo Phone Cable).
- IBM Compatible PC
SYSTEM CONFIGURATION
PC
Configuration
- Because the update requires RS-232C port of PC, all the configuration of Serial Port (COM1/COM2) should be done before proceed.
- If Communication (Serial) Port is not installed, check your CMOS (Computer System Menu) and activate Serial Port in it.
- Connect Serial Port of PC to Update Port of TV through RS-232C to Phone Cable.
- Main Power off (Unplug the power cord).
- Unzip Firmware File attached together and execute “FlashExpress_nologo.exe” in the folder.
- F/W Update is automatically started once power is on. You can see the progress bar as the above figure.
- Be sure to check the COM1/COM2 is selected right if it does not start.
- Wait till all the process is done. (It will take around 30 seconds to be done.)
(Firmware Update is completed.)
- After all the update process is done, do Factory Reset.
- To enter Factory Mode, push the buttons as following within 2 seconds.). ( 1 àMUTE àEnter àMUTE)
- In Factory Menu, Select [7/ Reset] and Push Enter.