MAIN BOARD - 715G3747-D
POWER BOARD - 715G3721
Internet Explorer SettingsWhen Windows XP SP2 or Windows Vista is used, ActiveX control and pop-up windows are limited by the enhanced security function and this system may not work. In that case, perform the Internet Explorer setting using the following procedure to restore normal operation
Windows version check
1. [My Computer (right-click)] - [Properties]
2. Internet Explorer setting - [Tools] - [Internet Options]
Using with Network
Precaution: To use ZEUS Service Manual Ver.2 with network, the file-path names written on the source files of each ZEUS Engine Program Ver.2 and ZEUS Service Manual Ver.2 are to be modified.
Perform the procedure described below.
Preparation
1. Run the program file zuesFPch.exe to install the program file for File-Path to the Local PC. -> Download zeusFPch_setup.zip (2.3MB)
2. Run the program file ZeusSetup_v2.0.exe to install the ZEUS Engine Program in C:\Program Files\zeus of the local PC. This can be done by running the installer program provided.
3. Create the appropriate folder where the ZEUS Engine Program Ver.2 and the ZEUS Service Manual Ver.2 to be stored in the server.
4. Move the ZEUS Engine Program of step 2 to the folder created at step 3 in the Server.
5. Detach the ZEUS Service Manual Ver.2 to the folder created at step 3 in the Server.
6. Unzip the ZEUS Service Manual Ver.2 within the folder in the Server.
Example of folder:
Procedure
of File-Path
The zeusFPch is the exclusive program to exchange the file-path names written in both source files of ZEUS Manual and ZEUS Engine program into those applicable to the network use.
The zeusFPch is the exclusive program to exchange the file-path names written in both source files of ZEUS Manual and ZEUS Engine program into those applicable to the network use.
Whenever
changing the file-path of both ZEUS Engine Program and ZEUS Service Manual to
use with network, pay the attention to set the "Exchange to" column
that should have a proper relation between ZEUS Engine Program and ZEUS Service
Manual with referring the following.
1. Run
the zeusFPch and set "Exchange to" by referring to the examples
below.
Example 1 :
In the "Exchange to" column shows the relation between ZEUS Service Manual and ZEUS Engine Program.
../ counts the relation between.
Thus in this case, it must be ../../zeus/ (2 counts).
Example 1 :
In the "Exchange to" column shows the relation between ZEUS Service Manual and ZEUS Engine Program.
../ counts the relation between.
Thus in this case, it must be ../../zeus/ (2 counts).
Example
2 :
In this case, it must be ../../../zeus/ (3 counts).
In this case, it must be ../../../zeus/ (3 counts).
2.
Run the zeusFPch to change the path in the ZEUS Engine Program Ver.2.
3. Set ZEUS Engine Program in the created folder in the server to the "Target Folder", and then press "START"
(This procedure is one time only)
3. Set ZEUS Engine Program in the created folder in the server to the "Target Folder", and then press "START"
(This procedure is one time only)
4.
Run the ZeusFPch to change the path in the ZEUS Service Manual Ver2.
5. Set unzipped ZEUS Service Manual in the created folder in the server to the "Target Folder", and then press "START". (This procedure is required whenever placing service manual.)
5. Set unzipped ZEUS Service Manual in the created folder in the server to the "Target Folder", and then press "START". (This procedure is required whenever placing service manual.)
Confirmation
Confirm that service manual on the server can be operated normally by client PC.
Note: In case of accessing the ZEUS Manual through WEB site, the small pop-up window appears at the left bottom corner on the screen whenever searching the location links. This is not malfunction.
Confirm that service manual on the server can be operated normally by client PC.
Note: In case of accessing the ZEUS Manual through WEB site, the small pop-up window appears at the left bottom corner on the screen whenever searching the location links. This is not malfunction.
A Known Malfunction
Autodesk® DWF™ Viewer version (Free software provided through WEB)
Use Autodesk DWF Viewer ver. 6.0.
Through WEB, ver. 6.5 has been released but with it, the linking function in this manual may not work properly.
If ver. 6.5 has been installed, uninstall it and reinstall ver. 6.0.
To
get ver. 6.0, click the icon, or contact to the nearest Toshiba Service Centre
for further assistance.
Freezing
windows opened (Cannot close the open
windows)
This
may happen occasionally. In case of encountering this, follow the procedure below.
1. Press [Ctrl], [Alt] and [Delete] keys at the same time to engage windows
security windows.
2. Then, choose TASK manager and Application tab, and select TOSHIBA SERVICE MANUAL-Microsoft Internet Explorer.
3. Click TASK-end.
2. Then, choose TASK manager and Application tab, and select TOSHIBA SERVICE MANUAL-Microsoft Internet Explorer.
3. Click TASK-end.
Main
Window back forwarded
The
real cause has not been found yet but with this condition, nothing disturbs the
service manual operation. Continue to
use by operating the windows.
Precaution
when opening the diagrams
While
opening the diagrams, the menu in the left frame changes its color to GRAY.
This is an indication that the viewer is processing.
With this condition, the menu indication color may stick to the GRAY color or Windows may freeze if clicking other menu.
To avoid such things, do not operate any others while menu turns GRAY color.
If entering this, re-open the service manual or refresh the left frame.
Audio amplifier schematic
[In the event that the screen is damaged or the liquid crystal (fluid) leaks, do not breathe in or drink this fluid. Also, never touch this fluid. Such actions could cause toxicity or skin irritation. If this fluid should enter the mouth, rinse the mouth thoroughly with water. If the fluid should contact the skin or clothing, wipe off with alcohol, etc., and rinse thoroughly with water. If the fluid should enter the eyes, immediately rinse the eyes thoroughly with running water]
With this condition, the menu indication color may stick to the GRAY color or Windows may freeze if clicking other menu.
To avoid such things, do not operate any others while menu turns GRAY color.
If entering this, re-open the service manual or refresh the left frame.
Audio amplifier schematic
[In the event that the screen is damaged or the liquid crystal (fluid) leaks, do not breathe in or drink this fluid. Also, never touch this fluid. Such actions could cause toxicity or skin irritation. If this fluid should enter the mouth, rinse the mouth thoroughly with water. If the fluid should contact the skin or clothing, wipe off with alcohol, etc., and rinse thoroughly with water. If the fluid should enter the eyes, immediately rinse the eyes thoroughly with running water]
To see the SMPS circuit diagram, visit the previous post here