Applicable to Philips 50PUG6513/78, 50PUG6513/77, 55PUG6513/78, 65PUG6703/77, 55PUG6703/77 Chassis TPM18.6L LA, Platform MTK5802
Mains power : AC
220-240V +/-10%
Power
saving features: Eco mode, Picture mute (for radio), Auto switch-off timer, Eco
settings menu.
Diagonal screen size
55PUG6703:
139 cm / 55 inch
65PUG6703:
164 cm / 55 inch
55PUx6513:
139 cm / 55 inch
50PUx6513: 126 cm / 50 inch
PAL,NTSC,SECAM
480i – 24Hz, 25Hz, 30Hz, 50Hz, 60Hz
480p– 24Hz, 25Hz, 30Hz, 50Hz, 60Hz
576i – 24Hz, 25Hz, 30Hz, 50Hz, 60Hz
576p– 24Hz, 25Hz, 30Hz, 50Hz, 60Hz
720p– 24Hz, 25Hz, 30Hz, 50Hz, 60Hz
1080i– 24Hz, 25Hz, 30Hz, 50Hz, 60Hz
1080p – 24Hz, 25Hz, 30Hz, 50Hz, 60Hz
Supported Input Resolution – Computer
640 x 480 – 60Hz
800 x 600 – 60Hz
1024 x 768 – 60Hz
1280 x 800 – 60Hz
1280 x 960 – 60Hz
1280 x 1024 – 60Hz
1366 x 768 – 60Hz
1440 x 900 – 60Hz
1920 x 1080 – 60Hz
3840 x 2160 – 60Hz
HDMI – UHD
(HOME)
> Settings > General settings > HDMI Ultra HD
This
TV can display Ultra HD signals. Some devices connected with HDMI – do not
recognize a TV with Ultra HD and might not work correctly or show distorted
picture or sound.
To
avoid the malfunctioning of such a device, you can set the signal quality to a
level the device can handle. If the device is not using Ultra HD signals, you
can switch off Ultra HD for this HDMI connection.
Identification:
The bottom line of a type plate gives a 14-digit serial number. Digits 1 and 2
refer to the production centre (e.g. SN is Lysomice, RJ is Kobierzyce), digit 3
refers to the B.O.M. code, digit 4 refers to the Service version change code,
digits 5 and 6 refer to the production year,
and digits 7 and 8 refer to production week (in example below it is 2010 week
10 / 2010 week 17). The 6 last digits contain the serial number.
It
should be noted that on the European Service website, “Alternative BOM” is
referred to as “Design variant”.
The
third digit in the serial number (example:
AG2B0335000001)
indicates the number of the alternative B.O.M. (Bill Of Materials) that has
been used for producing the specific TV set. In general, it is possible that
the same TV model on the market is produced with e.g. two different types of
displays, coming from two different suppliers. This will then result in sets
which have the same CTN (Commercial Type Number; e.g. 28PW9515/12) but which have
a different B.O.M. number.
By
looking at the third digit of the serial number, one can identify which B.O.M.
is used for the TV set he is working with. If the third digit of the serial
number contains the number “1” (example: AG1B033500001), then the TV set has
been manufactured according to B.O.M. number 1. If the third digit is a “2”
(example: AG2B0335000001), then the set has been produced according to B.O.M.
no. 2. This is important for ordering the correct spare parts.
Service Modes
The
Service Mode feature is split into following parts:
Service Alignment
Mode (SAM).
Factory Mode.
Customer Service Mode (CSM).SAM and the
Factory mode offer features, which can be used by the Service engineer to
repair/align a TV set.
SAM
and the Factory mode offer features, which can be used by the Service engineer
to repair/align a TV set. Some features are:
Make
alignments (e.g. White Tone), reset the error buffer(SAM and Factory Mode).
Display information (“SAM” indication in upper
right corner of screen, error buffer, software version, operating hours,
options and option codes, sub menus).
The
CSM is a Service Mode that can be enabled by the consumer. The CSM displays
diagnosis information, which the customer can forward to the dealer or call
centre. In CSM mode, “CSM”, is displayed in the top right corner of the screen.
The information provided in CSM and the purpose of CSM is to:
Increase the home repair hit rate.
Decrease the number of nuisance calls.
Solved customers’ problem without home visit.
Note:
For the new model range, a new remote control (RC) is used with some renamed buttons.
This has an impact on the activation of the Service modes.
For
instance the old “MENU” button is now called “HOME” (or is indicated by a
“house” icon).
Service Alignment Mode (SAM)
How
to Activate SAM
To
activate SAM, use one of the following methods:
Press the following key sequence on the remote
control transmitter: “062596”, directly followed by the “INFO/OK” button. Do
not allow the display to time out between entries while keying the sequence.
Or
via ComPair.
After
entering SAM, the following items are displayed, with “SAM” in the upper right
corner of the screen to indicate that the television is in Service Alignment
Mode.
How to Navigate
In the SAM menu, select menu items with the
UP/DOWN keys on the remote control transmitter. The selected item will be
indicated. When not all menu items fit on the screen, use the UP/DOWN keys to
display the next/previous menu items.
With the “LEFT/RIGHT” keys, it is possible to:
–
(De) activate the selected menu item.
–
(De) activate the selected sub menu.
–
Change the value of the selected menu item.
When
you press the MENU button once while in top level SAM, the set will switch to
the normal user menu (with the SAM mode still active in the background).
How to Store SAM Settings
To
store the settings changed in SAM mode (except the RGB Align settings), leave
the top level SAM menu by using the POWER button on the remote control
transmitter or the television set. The mentioned exceptions must be stored
separately via the STORE button.
How to Exit SAM
Use
one of the following methods:
Switch the set to STANDBY by pressing the
mains button on the remote control transmitter or the television set.
Via a standard RC-transmitter, key in “00”
sequence.
Note:
When the TV is switched “off” by a power interrupt while in SAM, the TV will
show up in “normal operation mode” as soon as the power is supplied again. The
error buffer will not be cleared.
Remark:
1.
Press following Key Combination to reset the “Op Hour”: “Menu/Home” + “101011”
on the remote control transmitter.
2.
Under main menu “NVM editor”, select “Service Data”, you can use the UP/DOWN
keys to view and change the set Type number, the set Production Number or the
18AC of a part.(The NVM-editor still has the same function as before,
alpha-numeric entry.)
Factory mode:
Displaying and or changing Panel ID
information.
Displaying and or changing Tuner ID
information.
Error buffer clearing.
Various software alignment settings.
Testpattern displaying.
Public Broadcasting Service password Reset.
etc.
To activate the Factory mode, use the following method:
Press the following key sequence on the remote
control transmitter: from the “menu/home” press
“1999”, directly followed by the “Back/Return”
button. Do not allow the display to time out between entries while keying the
sequence.
After
entering the Factory mode, we can see many items displayed, use the UP/DOWN
keys to display the next/previous menu items.
How to Exit the Factory mode
Select EXIT_FACTORY from the menu and press
the “OK” button.
Note:
When the TV is switched “off” by a power interrupt, or normal switch to
“stand-by” while in the factory mode, the TV will show up in “normal operation
mode” as soon as the power is supplied again. The error buffer will not be
cleared.
Customer Service Mode (CSM)
The
Customer Service Mode shows error codes and information on the TVs operation
settings. The call centre can instruct the customer (by telephone) to enter CSM
in order to identify the status of the set. This helps the call centre to
diagnose problems and failures in the TV set before making a service call.
The
CSM is a read-only mode; therefore, modifications are not possible in this
mode.
How to Activate CSM
To
activate CSM, press the following key sequence on a standard remote control
transmitter: “123654” (do not allow the display
to time out between entries while keying the sequence). After entering the
Customer Service Mode, the following items are displayed. use the Right/Left
keys to display the next/previous menu items.
Note:
Activation of the CSM is only possible if there is no (user) menu on the
screen.
How to Navigate
By
means of the “CURSOR-DOWN/UP” knob (or the scroll wheel) on the RC-transmitter,
can be navigated through the menus.
How
to Exit CSM
To
exit CSM, use one of the following methods.
Press the MENU/HOME button on the remote
control transmitter.
Press the POWER button on the remote control
transmitter.
Press the POWER button on the television set.
Software Upgrading, Error code and Panel Code.
The
following update is for .pkg file.
1.
Rename the file to “upgrade_loader.pkg”.
2.
Prepare a USB memory (File format: FLAT, Size: 1G~8G).
3.
Copy the software to USB flash disk (root directory).
4.
Switch off the TV and Insert the USB memory stick that contains the software update
files in one of the TV’s USB 2.0 port.
Note:
It contains USB3.0 port, if connect on it, the software may can’t be detected.
5.
Switch on the TV. The TV will detect the USB memory s tick automatically. Then
a window jumps out as below:
6.
When the TV software is updated, the TV will turn on again automatically.
Remove your USB flash drive.
7.
We can enter in CSM or Factory mode to check the current software version.
The
following update is for .upg file.
Step
1: Ready for F/W Upgrade
1.
Rename the file to “autorun.upg”.
2.
Prepare a USB memory (File format: FLAT, Size: 1G~8G).
3.
Copy the software to USB flash disk (root directory).
4.
Switch on the TV and Insert the USB memory stick that contains the software
update files in one of the TV’s USB 2.0 port.
Note
the version of this F/W before you change the software file name.
Step
2: F/W Upgrade
Press
[Quick settings], then Choose [Update Software] in the Settings menu
2.
Choose [Local Updates], then press OK.
3.
Select the file that you downloaded and press OK.
4.
Choose [Update], then choose [Start] on following step.
5.
Upgrade in progress.
Step
3: Check the SW version.
After
burning software, TV will restart
2.
Press “123654”, enter Customer Service Mode to
check if the software version is correct.
Caution:
Please make sure that software upgrade is finished before unplug the USB and AC
power.
Error Code
Error
codes are required to indicate failures in the TV set. In principle a unique
error code is available for every:
•
Activated (SW) protection.
•
Failing I2C device.
•
General I2C error.
The
last five errors, stored in the NVM, are shown in the Service menu’s. This is
called the error buffer.
The
error code buffer contains all errors detected since the last time the buffer
was erased. The buffer is written from left to right. When an error occurs that
is not yet in the error code buffer, it is displayed at the left side and all
other errors shift one position to the right.
An
error will be added to the buffer if this error differs from any error in the
buffer. The last found error is displayed on the left.
An
error with a designated error code never leads to a deadlock situation. It must
always be diagnosable (e.g. error buffer via OSD or blinking LED).
In
case a failure identified by an error code automatically results in other error
codes (cause and effect), only the error code of the MAIN failure is displayed.
How to Read the Error Buffer.
You
can read the error buffer in following ways:
On
screen via the SAM/CSM (if you have a picture).
Example:
–
ERROR: 000 000 000 000 000: No errors detected
–
ERROR: 013 000 000 000 000: Error code 13 is the last and only detected error
–
ERROR: 034 013 000 000 000: Error code 13 was detected first and error code 34
is the last detected (newest) error
Via the blinking LED procedure (when you have
no picture).
Error codes overview
In
this chassis only “layer 2” error codes are available and point to problems on
the SSB. They are triggered by LED blinking when CSM is activated. Only the following
layer 2 errors are defined:
How to Clear the Error Buffer.
The
error code buffer is cleared in the following cases:
By
using the CLEAR command in the SAM menu
By
using the CLEAR command in the Factory mode:
By
using the following key sequence on the remote control transmitter: “062599”
directly followed by the OK button.
If
the contents of the error buffer have not changed for 50 hours, the error
buffer resets automatically.
Note:
If you exit SAM by disconnecting the mains from the television set, the error
buffer is not reset.
Set Option Code
Press
the following key sequence on a standard RC transmitter: “062598” directly
followed by MENU and “xxx”, where “xxx” is a 3 digit decimal value of the panel
type: see column “Set Option Code” in below tab. After resetting the Display
Code, restart the set immediately.
Power board schematic
A 715G9309 PSU(For 55” 6703 Series)