APPLICABLE TO:
55PUT7374-98
70PUT7374-67
55PUT7374-56
70PUT7374-79
55PUT7374-67
70PUT7374-75
55PUT7374-79
70PUH7374-96
55PUT7374-75
55OLED804-98
55PUH7374-96
55OLED804-56
55PUT7374-68
55OLED804-67
65PUT7374-98
55OLED804-75
65PUT7374-56
55OLED804-79
65PUT7374-67
55OLED804-71
65PUT7374-79
65OLED804-98
65PUT7374-75
65OLED804-56
65PUH7374-96
65OLED804-67
65PUT7374-68
65OLED804-75
70PUT7374-98
65OLED804-79
70PUT7374-56
65OLED804-71
75PUT7354-56
Chassis: TPM19.1A LA
Platform: MTK5599
Always
respect voltages. While some may not be dangerous in themselves, they can cause
unexpected reactions that are best avoided. Before reaching into a powered TV
set, it is best to test the high voltage insulation. It is easy to do, and is a
good service precaution.
Sound
Output
power (RMS): 20W
Dolby
Atmos
Dolby
MS12D V2.2
Dolby
AC – 4
DTS
– HD (M6)
Diagonal screen size
•
126 cm - 50 inch
•
139 cm - 55 inch
•
164 cm - 65 inch
•
178 cm - 70 inch
•
189 cm - 75 inch
•
LNB : DiSEqC 1.0, 1 to 4 LNBs supported, Polarity selection 14/18V, Band
selection 22kHz, Tone burst mode, LNB current 300mA max.
Playback formats
•
Containers: PS, TS, M2TS, TTS, AVCHD, MP4, M4V, MKV, ASF, AVI, 3GP, Quicktime
•
Video Codecs : AVI, MKV, HEVC, H.264-MPEG-4 AVC, MPEG1, MPEG2, MPEG4, WMV9-VC1,
VP9, HEVC (H.265)
•
Audio Codecs : MP3, WAV, AAC, WMA (v2 up to v9.2), WMA-PRO (v9 and v10)
Supported
media server software (DMS)
•
You can use any DLNA V1.5 certified media server software (DMS class).
•
You can use the Philips TV Remote app (iOS and Android) on mobile devices.
Performance
may vary, depending on the capabilities of the mobile device and the software
used.
BOM identification
It
should be noted that on the European Service website, “Alternative BOM” is
referred to as “Design variant”.
The
third digit in the serial number (example:
AG2B0335000001)
indicates the number of the alternative B.O.M. (Bill Of Materials) that has
been used for producing the specific TV set. In general, it is possible that
the same TV model on the market is produced with e.g. two different types of
displays, coming from two different suppliers. This will then result in sets
which have the same CTN (Commercial Type Number; e.g. 28PW9515/12) but which
have a different B.O.M. number.
By
looking at the third digit of the serial number, one can identify which B.O.M.
is used for the TV set he is working with. If the third digit of the serial
number contains the number “1” (example: AG1B033500001), then the TV set has
been manufactured according to B.O.M. number 1. If the third digit is a “2”
(example: AG2B0335000001), then the set has been produced according to B.O.M. no.
2. This is important for ordering the correct spare parts.
For
the third digit, the numbers 1...9 and the characters A...Z can be used, so in
total: 9 plus 26= 35 different B.O.M.s can be indicated by the third digit of
the serial number.
Identification:
The bottom line of a type plate gives a 14-digit serial number. Digits 1 and 2
refer to the production centre (e.g. SN is Lysomice, RJ is Kobierzyce), digit 3
refers to the B.O.M. code, digit 4 refers to the Service version change code,
digits 5 and 6 refer to the production year, and digits 7 and 8 refer to
production week (in example below it is 2010 week 10 / 2010 week 17). The 6
last digits contain the serial number.
Board Level Repair (BLR) or Component Level Repair (CLR)
If
a board is defective, consult your repair procedure to decide if the board has
to be exchanged or if it should be repaired on component level.
If
your repair procedure says the board should be exchanged completely, do not
solder on the defective board. Otherwise,
it cannot be returned to the O.E.M. supplier for back charging.
Cable dressing
Disassembly of Power Supply Unit (PSU)
Caution:
it is mandatory to remount all different screws at their original position
during re-assembly. Failure to do so may result in damaging the PSU.
1.
Gently unplug all connectors from the PSU.
2.
Remove all fixation screws from the PSU.
3.
The PSU can be taken out of the set now.
Service Modes
The
Service Mode feature is split into following parts:
Service Alignment Mode (SAM).
Factory Mode.
Customer Service Mode (CSM).SAM and the
Factory mode offer features, which can be used by the Service engineer to
repair/align a TV set.
SAM
and the Factory mode offer features, which can be used by the Service engineer
to repair/align a TV set. Some features are:
Make alignments (e.g. White Tone), reset the
error buffer(SAM and Factory Mode).
Display information (“SAM” indication in upper
right corner of screen, error buffer, software version, operating hours,
options and option codes, sub menus).
The
CSM is a Service Mode that can be enabled by the consumer. The CSM displays
diagnosis information, which the customer can forward to the dealer or call
centre. In CSM mode, “CSM”, is displayed in the top right corner of the screen.
The information provided in CSM and the purpose of CSM is to:
Increase the home repair hit rate.
Decrease the number of nuisance calls.
Solved customers’ problem without home visit.
[Note: For the new model range, a new remote control (RC) is
used with some renamed buttons. This has an impact on the activation of the
Service modes. For instance the old “MENU” button is now called “HOME” (or is
indicated by a “house” icon).]
Service Alignment Mode (SAM)
To modify the NVM.
To display/clear the error code buffer.
To perform alignments.
Specifications
Operation hours counter (maximum five digits
displayed).
Software version, error codes, and option
settings display.
Error buffer clearing.
Option settings.
Software alignments (White Tone).
NVM Editor.
Set screen mode to full screen (all content is
visible).
How to Activate SAM
To
activate SAM, use one of the following methods:
Press the following key sequence on the remote
control transmitter: “062596”, directly followed
by the “INFO/OK” button. Do not allow the
display to time out between entries while keying the sequence.
Or via ComPair.
After
entering SAM, the following items are displayed, with “SAM” in the upper right
corner of the screen to indicate that the television is in Service Alignment Mode.
How to Navigate
In the SAM menu, select menu items with the
UP/DOWN keys on the remote control transmitter. The selected item will be
indicated. When not all menu items fit on the screen, use the UP/DOWN keys to
display the next/previous menu items.
With the “LEFT/RIGHT” keys, it is possible to:
–
(De) activate the selected menu item.
–
(De) activate the selected sub menu.
–
Change the value of the selected menu item.
When you press the MENU button once while in
top level SAM, the set will switch to the normal user menu (with the SAM mode
still active in the background).
How to Store SAM Settings
To
store the settings changed in SAM mode (except the RGB Align settings), leave
the top level SAM menu by using the POWER button on the remote control transmitter
or the television set. The mentioned exceptions must be stored separately via
the STORE button.
How to Exit SAM
Use
one of the following methods:
Switch the set to STANDBY by pressing the
mains button on the remote control transmitter or the television set.
Via a standard RC-transmitter, key in “00” sequence.
Note:
When the TV is switched “off” by a power interrupt while in SAM, the TV will
show up in “normal operation mode” as soon as the power is supplied again. The
error buffer will not be cleared.
[Under main menu “NVM editor”, you can use the UP/DOWN keys to
view and change the set Type number, the set Production Number or the 18AC of a
part.(The NVM-editor still has the same function as before, alpha-numeric
entry.)]
How to Activate the Factory mode
To
activate the Factory mode, use the following method:
Press the following key sequence on the remote
control transmitter: from the “menu/home” press “1999”,
directly followed by the “Back/Return” button.
Do not allow the display to time out between entries while keying the sequence.
After
entering the Factory mode, we can see many items displayed, use the UP/DOWN
keys to display the next/previous menu items.
How to Exit the Factory mode
Select EXIT_FACTORY from
the menu and press the “OK” button.
Note:
When the TV is switched “off” by a power interrupt, or normal switch to
“stand-by” while in the factory mode, the TV will show up in “normal operation
mode” as soon as the power is supplied again. The error buffer will not be
cleared.
Customer Service Mode (CSM)
How
to Activate CSM
To
activate CSM, press the following key sequence on a standard remote control
transmitter: “123654” (do not allow the display
to time out between entries while keying the sequence). After entering the
Customer Service Mode, the following items are displayed. use the Right or Left
keys
to
display the next or previous menu items
Note:
Activation of the CSM is only possible if there is no (user) menu on the
screen.
How to Navigate
By
means of the “CURSOR-DOWN or UP” knob (or the scroll wheel) on the
RC-transmitter, can be navigated through the menus.
How to Exit CSM
To
exit CSM, use one of the following methods.
Press the MENU/HOME button on the remote
control transmitter. Or Press the POWER button on the remote control
transmitter. Or Press the POWER button on the television set.
Software Upgrading, Error code and Panel Code
The
following update is for .pkg file.
1.
Rename the file to “upgrade_loader.pkg”.
2.
Prepare a USB memory (File format: FLAT, Size: 1G~8G).
3.
Copy the software to USB flash disk (root directory).
4.
Switch off the TV and Insert the USB memory stick that contains the software
update files in one of the TV’s USB 2.0 port.
Note:
It contains USB3.0 port, if connect on it, the software may can’t be detected.
5.
Switch on the TV. The TV will detect the USB memory s tick automatically. Then
a window jumps out as below:
6.
When the TV software is updated, the TV will turn on again automatically.
Remove your USB flash drive.
7.
We can enter in CSM or Factory mode to check the current software version.
The
following update is for .upg file.
Ready
for Firmware Upgrade:
1.
Rename the file to “autorun.upg”.
2.
Prepare a USB memory (File format: FLAT, Size: 1G~8G).
3.
Copy the software to USB flash disk (root directory).
4.
Switch on the TV and Insert the USB memory stick that contains the software
update files in one of the TV’s USB 2.0 port.
Note
the version of this firmware before you change the software file name.
Firmware Upgrade
Press
[Settings], then Choose [Search for update] in the Settings menu.
2.
Choose [USB], and then press OK.
3.
Choose [Identify], and then press OK.
4.
.Select the file that you downloaded and press OK.
5.
Identify the software and choose [Done], then choose [Start] on following step.
6.Choos
[Update] press OK start the software update.
6.
Upgrade in progress.
Check the SW version
After
burning software, TV will restart
2.
Press “123654”, enter Customer Service Mode to
check if the software version is correct.
Make sure
that software upgrade is finished before unplug the USB and AC power.
Error
Code Error codes are required to indicate failures in the TV set. In principle
a unique error code is available for every:
•
Activated (SW) protection.
•
Failing I2C device.
•
General I2C error.
The
last five errors, stored in the NVM, are shown in the Service menu’s. This is
called the error buffer.
The
error code buffer contains all errors detected since the last time the buffer
was erased. The buffer is written from left to right. When an error occurs that
is not yet in the error code buffer, it is displayed at the left side and all
other errors shift one position to the right.
An
error will be added to the buffer if this error differs from any error in the
buffer. The last found error is displayed on the left.
An
error with a designated error code never leads to a deadlock situation. It must
always be diagnosable (e.g. error buffer via OSD or blinking LED).
In
case a failure identified by an error code automatically results in other error
codes (cause and effect), only the error code of the MAIN failure is displayed.
How to Read the Error Buffer
You
can read the error buffer in following ways:
•
On screen via the SAM/CSM (if you have a picture).
Example:
–
ERROR: 000 000 000 000 000: No errors detected
–
ERROR: 013 000 000 000 000: Error code 13 is the last and only detected error
–
ERROR: 034 013 000 000 000: Error code 13 was detected first and error code 34
is the last detected (newest) error
•
Via the blinking LED procedure (when you have no
picture).
Error codes overview
In
this chassis only “layer 2” error codes are available and point to problems on
the SSB. They are triggered by LED blinking when CSM is activated. Only the
following layer 2 errors are defined:
How to Clear the Error Buffer
The
error code buffer is cleared in the following cases:
•
By using the CLEAR command in the SAM menu
•
By using the CLEAR command in the Factory mode:
•
By using the following key sequence on the remote control transmitter: “062599” directly followed by the OK button.
•
If the contents of the error buffer have not changed for 50 hours, the error
buffer resets automatically.
Note:
If you exit SAM by disconnecting the mains from the television set, the error
buffer is not reset.
Set Option Code
Press
the following key sequence on a standard RC transmitter: “062598” directly followed by
MENU and “xxx”, where “xxx” is a 3 digit decimal value of the panel
type: see column “Set Option Code” in below tab. After resetting the Display
Code, restart the set immediately.
Power layout SSB
Power SSB Top View (For 715GA046M)
SMPS [POWER] A 715GA018 PSU(For 55”/65” 7374 Series)
SMPS [POWER] A 715GA025 PSU (For 70” 7374 & 75” 7354 Series)
SMPS [POWER] A 715G9892 PSU (For 55”/65” OLED Series)
No comments: