Friday, October 17, 2014

SONY KDS-R50XBR1- KDS-R60XBR1 - LED BLINKING CODES - LAMP REPLACEMENT

SONY - KDS-R50XBR1- KDS-R60XBR1 [RM-Y914 USA & Canada] - SXRD PROJECTION TV
Lamp Replacement_lamp time reset_LED blinking codes_Self Diagnosis
Universal Remote Control Set-up Codes
LAMP REPLACEMENT
* Turn off the power on the main unit. Wait several minutes, then unplug the power cord.  (The cooling fan will continue to operate for about two minutes after turning the power off.)
* Wait at least 30 minutes after unplugging the power cord to allow the lamp to cool down before replacing it. To avoid being burned, do not touch the lamp receptacle once the lamp has been removed.
* Take the new lamp out of its package. Turn the screw with a screwdriver ccounter-clockwiseand remove the outside lamp cover. Pull out the lamp.  Place your index finger through the hoop of the lamp handle and pull it upwards, while placing your thumb on the dent on the top. Then pull the lamp out.
* Place the lamp halfway in. Follow the gutter in the compartment to mount the new lamp securely.
Slide it in slowly by pressing the [PUSH] part of the front corners of the lamp until it stops with a firm clicking sound to lock.
* Place the outside lamp cover back in its place. Turn the screw with a screwdriver clockwise and secure the cover.
 [This product contains mercury. Disposal of this product may be regulated if sold in the United States. Do not leave the used lamp near flammable materials or within the reach of children.  Do not pour water onto the used lamp or put any object inside the lamp.  Doing so may cause the lamp to burst.]
To read Lamp and Panel time
The lamp and panel time of the set are displayed as follows.
Enter the service mode
* Press the keys of the remote commander in rapid sequence as follows, when the set is in standby mode.
DISPLAY > CHANNEL (5) > VOLUME (+) > POWER
* Press the “JUMP” key [3 times].  You’ll get into DE-micro service menu .
* Press “2 ” key [9 times] to show the following display.
PANEL NVM OK 9 OPTION_E
0 LAMP 0 Diff 1
LampTM 14 LampCT 71
This screen reads
“Total lamp time is 14 hours” and “Total lamp ON/OFF cycle is 71 times”
>> To reset lamp time, press “3 ”,“MUTE ” and “ENTER ” keys in sequence.  WRI-EXE (Red Character) is momentarily displayed and LampTM will be reset to “0 ”  
 
* Press “1” key [7 times].  
PANEL NVM OK 9 OPTION_E
7 SH SFT1 10 Diff 1
PanelTM 14h
This screen reads 
"Total Panel time is 14 hours”
{You can’t reset the Panel time with the Service menu.}
To get out of the Service menu
The Service menu is cleared by turning off the set with a remote commander or the power switch.
Test Reset
The user settings can be reset to the factory default condition as follows.
Press “TEST “ and “RESET “ key in sequence when the set is ON .  The LAMP, TIMER and POWER/STANDBY LED light and the picture is muted.  After about 5 seconds the LAMP and TIMER LED go off, and the colour of POWER/STANDBY LED changes from amber to green.
After another 10 seconds the reset is completed and the initial set-up display appears.
Self-Diagnosis Function
This device includes a self-diagnosis function.
In case of abnormalities, the POWER/STANDBY indicator automatically blinks. It is possible to predict the abnormality location by the number of blinks. The Instruction Manual describes blinking of the POWER/STANDBY indicator.
If the symptom is not reproduced sometimes in case of a malfunction, there is recording of whether a malfunction was generated or not. Operate the remote command to confirm the matter on the screen and to predict the location of the abnormality.
Diagnosis Items and Prediction of Malfunction Location
When a malfunction occurs the POWER/STANDBY indicator only blinks for one of the following diagnosis items. In case of two or more malfunctions, the item which first occurred blinks. If the malfunctions occurred simultaneously, the item with the lower blink count blinks first.  The screen display displays the results regarding all the diagnosis items listed below.  The display "0" means that no malfunctions occurred.
To Release of POWER/STANDBY indicator blinking
The POWER/STANDBY indicator blinking display is released by removing the plug from the power or leaving for 2 minutes.
Self-diagnosis screen displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether the detection circuit operated or not) in order to allow confirmation.
Screen Display Method
Quickly press the remote command button in the following order from the standby state.
DISPLAY > CHANNEL (5) > VOLUME (--) > POWER
# Numeral "1" means a fault was detected one time.
# Numeral "0" means that no fault was detected.
The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure to return the results display to "0".
If the results display is not returned to "0" it will not be possible to judge a new malfunction after completing repairs.
Method of Ending the Self-Diagnosis Screen
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
Self-Diagnosis function operation
2) Temp >>  When the temperature sensor (for Ambient) on the S1 board detects high temperature or the temperature sensor (for Lamp) on the S2 board detects high temperature or the temperature sensor (for Panel) on the C board detects high temperature, the DE-micro (IC5) turns off the lamp.
3) Lamp cover >> The rib at the back of the lamp cover closes the SW on the T1 board. The lamp closes the SW on the T2 board.  It is monitored by DE-micro (pin63 of IC5) and turned off the lamp when it is opened.
4) Fan >> Fan rotation is detected by ‘‘FAN-PROT” and the DE-micro (pin92 of IC5) turns off the lamp when it is ‘‘high”.
5) Lamp Driver >> When the ‘‘LAMP-PROT” (pin83 of IC5) is high, the lamp is not turned on.  If the ‘‘LAMP-HV-DET” (pin94 of IC5) is low at the same time, it classified as no high voltage of the lamp driver.
6) Low B error >> When no ‘‘D5V (SW_5V)” is detected, pin 129 of TV-micro (IC7002) is low and it turns off the main power. (for example, blowout of thermal fuse).
7) Audio >> When DC voltage is detected at the speaker output, ‘‘SP-PROT” (pin102 of IC5) is low and it turns off the main power.
8) D-OVP >> Be not in use.
9) Panel error >> When there is no track from the temperature sensor on the S1, S2 and C board or IIC line connector (CN2303: ASU board, CN7956: DSU board, CN6901: C board) is not seated securely. It is monitored by DE-micro.
10) ATSC-OVP >> Be not in use.
(LAMP) - Lamp >> When the ‘‘LAMP-PROT” (pin83 of IC5) is high, the lamp is not turned on. If the ‘‘LAMP-HV-DET” (pin94 of IC5) is high at the same time, it classified as no lamp or a dead lamp.
Universal remote control set-up codes to Sony Brand TVs.
0018 0045 0101 0131 0154 0177 0211 0301 0302 0357 0358 0609 0785