Applicable to: W580B/W585B/W590B/W600B/W605B/W607B/W608B/WM15B
KDL-40W580B
KDL-48W580B KDL-60W600B
KDL-40W590B KDL-48W585B KDL-60W605B
KDL-40W600B KDL-48W590B KDL-60W607B
KDL-40W605B KDL-48W600B KDL-60W608B
KDL-40W607B KDL-48W605B KDL-60W610B
KDL-40W608B KDL-48W607B KDL-60W630B
KDL-48W608B KDL-60WM15B
KDL-48WM15B
ASIA
CHINA AMERICA JAPAN & EUROPEKDL-40W590B KDL-48W585B KDL-60W605B
KDL-40W600B KDL-48W590B KDL-60W607B
KDL-40W605B KDL-48W600B KDL-60W608B
KDL-40W607B KDL-48W605B KDL-60W610B
KDL-40W608B KDL-48W607B KDL-60W630B
KDL-48W608B KDL-60WM15B
KDL-48WM15B
SERVICE ADJUSTMENTS
Accessing Service Mode
1) Go to TV standby condition by remote commander.
2) Press “i+ (info)”, “5”, “Volume +” then “TV power” on remote.
3) You can see Service Mode on display.
* The above operation should be finished within 15 seconds after the set go to STBY mode.
Transition
of Each Micro’s Service Mode
OPTIONS
1. First of all, when you enter Service Mode, you can see “Digital” service mode.
2. Whenever you press “OPTIONS” on remote, service mode is changed according to the flow below:
OPTIONS
1. First of all, when you enter Service Mode, you can see “Digital” service mode.
2. Whenever you press “OPTIONS” on remote, service mode is changed according to the flow below:
Digital” > “Chassis” > “VPC”
Part
A “Chassis” & “VPC”
Part
B “Digital” service mode.
Change Data by Service Mode 1 (Part A)
Change Data of “Chassis” or “VPC” service mode
a. Press “2 / 5” on remote to select (up / down) category.
b. Press “1 / 4” on remote to select (up / down) Item.
c. Press “3 / 6” on remote to change (up / down) data.
Save Changing Data by Service Mode 1
2. Write data for “Chassis” or “VPC” service mode.
a. Press “Mute” on remote. It shows green “SERVICE” changes to green “WRITE”.
b. Press “0” on remote. Green “WRITE” changes to red “WRITE”. It indicates writing is processing.
c. After a while, red “WRITE” changes to green “SERVICE”. Writing process is done at this point.
3. TV reboot is necessary for applying data change.
Change
Data by Service Mode 2 (Part B)
Change
Data of “Digital” service mode (except “003 DIG_SRV_MODE” category)
a. Press “2 / 5” on remote to select (up / down) category.
b. Press “1 / 4” on remote to select (up / down) Item.
c. Press “3 / 6” on remote to change (up / down) data.
a. Press “2 / 5” on remote to select (up / down) category.
b. Press “1 / 4” on remote to select (up / down) Item.
c. Press “3 / 6” on remote to change (up / down) data.
[“Digital”
service mode don’t have to Save. (except “002 MODEL”)]
2.
Change Data of “Digital” service mode ( “003 DIG_SRV_MODE” category). “003
DIG_SRV_MODE” is one category of “Digital” service mode. Please note because
this operation is special.
a. Press “2 / 5” on remote to select “003 DIG_SRV_MODE”.
b. Press “1 / 4” on remote to select (up / down) Item.
c. Press “0 / 10” on remote to select item.
d. Press number key “1”~”9” directly. “*” stamp move.
e. Press “12 / enter / select” to decide and advance to the next step. Press “return”, to return to the previous page.
a. Press “2 / 5” on remote to select “003 DIG_SRV_MODE”.
b. Press “1 / 4” on remote to select (up / down) Item.
c. Press “0 / 10” on remote to select item.
d. Press number key “1”~”9” directly. “*” stamp move.
e. Press “12 / enter / select” to decide and advance to the next step. Press “return”, to return to the previous page.
Checking
Board Information
In
“Digital” service mode ( “002 MODEL” category)
2. Press “0 / 10” on remote to select item.
2. Press “0 / 10” on remote to select item.
3.
Press “1” on Remote
Note
: Check the Result. Result 1 : NG ,
Result 2: OK, Result 3 : OK (With “TUNER BOARD OPTION is changed correctly”) comment.
Result 2: OK, Result 3 : OK (With “TUNER BOARD OPTION is changed correctly”) comment.
This
case is NG. The main board is mismatch to the tuner board.
The value of Tuner Board Option was kept.
The value of Tuner Board Option was kept.
4.
Press “Return” on Remote
5. Press “2” on Remote.
5. Press “2” on Remote.
This
case is NG.
The main board is mismatch to the tuner board.
The value of Tuner Board Option was kept.
The main board is mismatch to the tuner board.
The value of Tuner Board Option was kept.
This
case is OK.
The value of Tuner Board Option was kept.
In this case, The value of Tuner Board Option is never changed automatically.
The value of Tuner Board Option was kept.
In this case, The value of Tuner Board Option is never changed automatically.
6.
Press “Return” on Remote.
[IF “OK” Go to Save Changing Data by Service
Mode 2.]
Save
Changing Data by Service Mode 2 [Only when B* board is replaced.]
In
“Digital” service mode ( “002 MODEL” category)
001 SEG Select segment information
002 DEST Select destination information
003 MODELNAME Select Model Name
004 SERIAL Can be set Only Once for the new board
005 SHIP_CONFIRM...Can set correct Product Code
006 VAR_TYPE Select variable information.
001 SEG Select segment information
002 DEST Select destination information
003 MODELNAME Select Model Name
004 SERIAL Can be set Only Once for the new board
005 SHIP_CONFIRM...Can set correct Product Code
006 VAR_TYPE Select variable information.
Change
data for each model.
b. Press “Mute”, “0” on remote sequentially. Red “WRITE” is shown. This indicates writing is in process.
c. After a while, red “WRITE” disappears. Green Done will be displayed for a while, which means writing process is done.
d. For the items SEG, DEST, MODELNAME after changing each item, service save (“mute”+”0”) is required. For the item SERIAL, after inputting the serial number, press key “12” or “Enter” to save the data.
b. Press “Mute”, “0” on remote sequentially. Red “WRITE” is shown. This indicates writing is in process.
c. After a while, red “WRITE” disappears. Green Done will be displayed for a while, which means writing process is done.
d. For the items SEG, DEST, MODELNAME after changing each item, service save (“mute”+”0”) is required. For the item SERIAL, after inputting the serial number, press key “12” or “Enter” to save the data.
Please
save the items according to the sequence “SEG -> DEST -> MODELNAME->
VAR_TYPE”
– When Saving the item "SEG", sometimes instead of "Writing", the word "Pending" will appear. In this case, skip "SEG", saving "DEST“ , "MODELNAME“ and “VAR_TYPE” is OK.
– When Saving the item "SEG", sometimes instead of "Writing", the word "Pending" will appear. In this case, skip "SEG", saving "DEST“ , "MODELNAME“ and “VAR_TYPE” is OK.
Restore
WB / Gamma Adj. Data to B board.
[apply
after USB-DL when B board is replaced. HE,HS
Models]
1.in
“VPC” service mode
a.Select “000 DATA_COPY” category by pressing “2 / 5” on remote.
b.Change data from “0” to “1” by pressing “3 / 6” on remote.
c.Wait until data is changed from 1 to 3.
d.When data is changed from 1 to 3, restoring process is finished.
e.In case data is changed from 1 to 2, keep default setting. (No more process is needed.)
a.Select “000 DATA_COPY” category by pressing “2 / 5” on remote.
b.Change data from “0” to “1” by pressing “3 / 6” on remote.
c.Wait until data is changed from 1 to 3.
d.When data is changed from 1 to 3, restoring process is finished.
e.In case data is changed from 1 to 2, keep default setting. (No more process is needed.)
WB [White Balance] Adjustment by Service Mode
1. in “VPC” service mode (“004 WB” category)
a. Press “1” or “4” on remote to select WB adjustment menu.
b. Change data by pressing “3” or “6”. Each range of these items is 0~1023.
c. Press “mute” +”0” on remote to save the data. “SERVICE” comment is changed to “WRITE”, indicating writing process.
d. After a while, “WRITE” comment returns to “SERVICE”, which means writing process is done. (takes about a couple of seconds)
1. in “VPC” service mode (“004 WB” category)
a. Press “1” or “4” on remote to select WB adjustment menu.
b. Change data by pressing “3” or “6”. Each range of these items is 0~1023.
c. Press “mute” +”0” on remote to save the data. “SERVICE” comment is changed to “WRITE”, indicating writing process.
d. After a while, “WRITE” comment returns to “SERVICE”, which means writing process is done. (takes about a couple of seconds)
VCOM Adjustment (NFR-AUO/SDC/FXC Panel)
STEP1
DIGITAL (DIG_SRV_MODE) SERVICE
TEST PATTERN
> 1 Video
*1 White
2 Ramp
3 R Raster
4 G Raster
5 B Raster
6 Color Bar
7 VCOM Pattern1
8 VCOM Pattern2
9 Off
1. in “Digital” service mode
a. Select “003 DIG_SRV_MODE” category by pressing “2 / 5” on remote.
b. Press “0” to go to “TEST PATTERN” Mode.
c. Press “Enter” or “12” to go into Video TEST PATTERN.
d. Press “7” or “8” to select the test pattern
e. Press “Enter” or “12” twice to show the VCOM TEST PATTERN.
STEP2
VPC SERVICE
002 VCOM
000 ENABLE 0
2.in “VPC” service mode
a. Select “002 VCOM” category by pressing “2 / 5” on remote.
b. Select “000 ENABLE” item by pressing “1 / 4” on remote.
c. Change ENABLE from “0” to “1” by pressing “3” to enable VCOM adjustment.
STEP3
VPC SERVICE
002 VCOM
001 ADJUST 64
3. in “VPC” service mode
a. Select “002 VCOM” category by pressing “2 / 5” on remote.
b. Select “001 ADJUST” item by pressing “1 / 4” on remote.
c. Change data by pressing “3 / 6” on remote.
STEP4
4. in “Digital” service mode
a. Select “007 VCOM” category by pressing “2 / 5” on remote.
b. Change data from “1” to “0” by pressing “3 or 6 ” on remote.
c. Confirm the final result of the VCOM adjustment .
d. If OK, Finish the VCOM adjustment. If NG, pressing “3 or
6” to show the OSD again and go back to VCOM adjustment Step 3.
VCOM Adjustment (HFR-AUO/FXC Panel)
VPC SERVICE
002 VCOM
000 ENABLE 0
1. in “VPC” service mode
Select “002 VCOM” category by pressing “2 / 5” on remote.
b. Select “000 ENABLE” item by pressing “1 / 4” on remote..
c. Change ENABLE from “0” to “1” by pressing “3” to enable VCOM adjustment.
-The Picture is change Vcom Pattern and you can’t see OSD
STEP2
in
“VPC” service mode (There is no OSD.)
Select
“002 VCOM” category by pressing “2 / 5” on remote.
b. Select “001 ADJUST” item by pressing “1 / 4” on remote.
c. Change data by pressing “3 / 6” on remote.
d. Finish the adjustment when the picture seems OK.
e. Select “000 ENABLE” item by pressing “1 / 4” on remote.
f. Change ENABLE from “1” to “0” by pressing “6” to disable VCOM adjustment. And you can see OSD.
b. Select “001 ADJUST” item by pressing “1 / 4” on remote.
c. Change data by pressing “3 / 6” on remote.
d. Finish the adjustment when the picture seems OK.
e. Select “000 ENABLE” item by pressing “1 / 4” on remote.
f. Change ENABLE from “1” to “0” by pressing “6” to disable VCOM adjustment. And you can see OSD.
REC
Setting - STEP1
in
“Digital” service mode
a.Select “003 DIG_SRV_MODE” category by pressing “2 / 5” on remote.
b. Select “006 REC_SETTING ” item by pressing “1 / 4” on remote.
c. Press “0” or “10” to go to detailed REC setting screen.
a.Select “003 DIG_SRV_MODE” category by pressing “2 / 5” on remote.
b. Select “006 REC_SETTING ” item by pressing “1 / 4” on remote.
c. Press “0” or “10” to go to detailed REC setting screen.
STEP2
in
detailed REC setting screen
a. Press “1” to select “Key Copy” item
b. Press “Enter” or “12” twice to execute the command.
c. If OK, show the message “Key Copy OK”. If NG, show the message “Key Copy NG (= xx )”.
d. Press “Return” to return to previous page.
a. Press “1” to select “Key Copy” item
b. Press “Enter” or “12” twice to execute the command.
c. If OK, show the message “Key Copy OK”. If NG, show the message “Key Copy NG (= xx )”.
d. Press “Return” to return to previous page.
STEP3
in
detailed REC setting screen
a. Press “2” to select “HDD Re-Register” Item.
b. Press “Enter” or “12” twice to execute the command.
c. If OK, xx= x+1. If NG, xx=x.
d. Press “Return” to return to previous page.
a. Press “2” to select “HDD Re-Register” Item.
b. Press “Enter” or “12” twice to execute the command.
c. If OK, xx= x+1. If NG, xx=x.
d. Press “Return” to return to previous page.
Reset
Panel Operation Time [Only when Panel is replaced.]
In
Self Diagnosis Display
a. Reset Panel Operation Time <7> -> <0>
a. Reset Panel Operation Time <7> -> <0>
Set to Shipping Condition
How to do shipping condition.
a. Move to “Digital” service mode.
b. Press “8” on remote. It shows green “SERVICE” changes to green “RST-”.
c. Press “mute” on remote. Added green “EXE” after green “RST-” .
d. Press “0” on remote. Green “EXE-RST” changes to red “EXERST”. It indicate writing is processing.
e. After a while, red “EXE-RST” changes to green “SERVICE”.
f. And blink Smart Core WHITE LED. Writing process is done at this point.
Another
way
You can set to shipping condition w/o entering Service Mode.
> “Cursor Up” + “Power Key” on remote.
You can set to shipping condition w/o entering Service Mode.
> “Cursor Up” + “Power Key” on remote.
How
to Enter Self Diagnosis Display
Go
to TV standby condition by remote commander.
2. Press “i+ (info)”, “5”, “Volume-” then “TV power” on remote.
3. You can see Self Diagnosis Display.
4. To Exit , Press Power Off and On.
2. Press “i+ (info)”, “5”, “Volume-” then “TV power” on remote.
3. You can see Self Diagnosis Display.
4. To Exit , Press Power Off and On.
Self Diagnosis Display [Part i)
Format of error time stamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp is saved.
*Following error is invalid in RB1.
- FAN_ERR
- EMIT_ERR
- TCON_ERR
Error history clear <8> -> <0>
Panel operation time clear <7> -> <0>
•Panel
Operation Time is recorded every 30 min, but Total Operation Time is recorded
every 1 hr. Therefore, the panel op. time might become larger than the total
op. time.
Self
Diagnosis Display (Part ii)
USB dongle:
1. When no Wi-Fi USB dongle is connected, NA is displayed.
2. If you insert/disconnect Wi-Fi USB Dongle during Self Diagnosis Display, press <1> - > <4> on remote commander to refresh MAC address displayed on “USB dongle”.
- Alternatively, you can re-display Self Diagnosis Display to update the information.
USB dongle:
1. When no Wi-Fi USB dongle is connected, NA is displayed.
2. If you insert/disconnect Wi-Fi USB Dongle during Self Diagnosis Display, press <1> - > <4> on remote commander to refresh MAC address displayed on “USB dongle”.
- Alternatively, you can re-display Self Diagnosis Display to update the information.