LG 47LG90 LED BACK LIGHT TROUBLESHOOTING

ENTIRE PANEL WON'T LIGHT
  1. Is the 24V being supplied to the inverters from SMPS? [CN1/CN501 pins-1-5].
  2. Is the inverter On Command arriving at both inverters? [CN 1/CN 501 pin-12] [ Main to SMPS P-201 pin-20].
  3. Disconnect the ribbon cables from the T-Con board to the inverters.  If back light turns ON, could be a T-Con problem.
1/2 THE PANEL WON'T LIGHT
  • Confirm steps 1 & 2 above for the particular inverter involved. 
  • Disconnect the ribbon cable from the T-Con board going to the particular inverter involved, could be a T-Con problem [CN8/CN9]
SECTIONS OF 1/2 THE PANEL WON'T LIGHT
  1. Locating the connection corralling that particular section should be easy.  Just compare the section that is out and align with the particular cable.
  2. Looking at the connector going to the LED back lights, look at the bottom 2 pins on 'M' inverter or the top of 2 pins of the 'S' inverter, check for 39V?  If missing, unplug the connector and recheck.  Still missing?
  3.  Using the interconnect diagram, locate the fuse protecting the 24V to the DC to DC converter that is developing the 39V for that connector.  If found open, replace the inverter.
  4. Be sure to test the back light LEDs that attach to that connector for shorted condition.  With the connector unplugged put the Red lead on the the bottom 2 pins on the 'M' inverter or top 2 pins of the 'S' driver, and the Black lead on any other 8 pins.  All should read 'open'. Or, apply 30-38V on the bottom 2 pins on the "M" inverter or top 2 pins of "S" inverter, and the ( - ) lead to any of the other 8 pins while observing that section of the panel, the LEDs should illuminate across the screen in the section controlled by that plug.
ENTIRE PANEL BACK LIGHTS ARE DIM
  • Disconnect the ribbon cables from the T-Con PWB to the inverters, could be a T-Con problem [CN8/CN9]