Thursday, September 20, 2012

SAMSUNG DLP PROJECTION TV LED blinking codes - Initialization process



INITIALIZATION PROCESS


  • Standby LED on Analog PCB ON [5V].
  • Power ON signal from the Sub Front PCB or Infrared Sensor [IR sensor] to Digital PCB.
  • Power ON signal generated by Digital PCB -> Analog PCB -> Power PCB.
  • All other voltages turn On [Three Status LEDs on Analog Board lit]
  • Fans turns ON.
  • Fan Protection circuit verifies fan operation.
  • Digital PCB tells DMD PCB to turn Color Wheel and Lamp On.
  • The DMD | Digital PCBs check feedback  [lamplitz - low, DDP ready - high] signals from Lamp and DMD controller [DDP1011]
  • If OK, Digital PCB tells DMD to remove 'Video Mute'.
LED BLINKING CODES

Timer
Lamp
Standby | Temp
Indication

OFF
OFF
ON
STANDBY STATE
ON
OFF
OFF
AUTO TIMER ON/OFF HAS BEEN SET
OFF
OFF
OFF
SET IS OPERATING NORMALLY
OFF
ON
OFF
TURN ON STATE, PICTURE WILL APPEAR IN ABOUT 15 SECONDS
BLINK
BLINK
OFF
AUTO TIMER ON/OFF HAS BEEN SET, PICTURE WILL APPEAR IN APPROXIMATELY 25 SECONDS
BLINK
OFF
BLINK
A COOLING FAN INSIDE THE SET IS NOT OPERATING PROPERLY
OFF
BLINK
BLINK
THE LAMP COVER ON THE REAR OF THE SET IS NOT INSTALLED PROPERLY
OFF
OFF
BLINK
EXCESSIVE TEMPERATURE ERROR, CHECK FOR PROPER VENTILATION
BLINK
BLINK
BLINK
LAMP DOES NOT LIGHT, REPLACE WITH NEW LAMP