Samsung HTC330 - How to change the region code, How to initialize, Protection circuit operations and more

Samsung Digital Home Cinema System HT-C330 - Model Code : HT-C330-XSS
Buyer-Region Code Setting Method
The inserting method of Region Code after replacing the Main PBA
When replacing the Main PBA and System Micom should be inserted the region code.
* The set is not working properly if you don't insert the region code.
* The region code is inserted by the remote control.
Procedure
1. Press the “AUX” button on the remote control.
2. Press the "TUNER MEMORY" button on the remote control during 4~5 seconds.
3. After step (2), you can see “TEST” on the VFD.
4. When you see “TEST” on VFD, Insert number “4”, “6” to start Region Code setting mode.
5. After step (4), you can see “- -” on the VFD.
Insert the Region Code (Below table) corresponding model with “0 ~ 9” buttons on the remote control.
6. After step (5), you can see “15 USA” on the VFD.
It means that currently System Micom program is installed by USA specification.
In case of System Micom and EEPROM problem, you can apply to this.
For example, during Updating program of System Micom, if Updating fail is happened, it is impossible to turn on the system from stand-by status.
The system will keep the stand-by status continuously, and the touch-key function will never work.
In this case, you have to change System Micom, and set up the Buyer Region code again.
In case of EEPROM, you don't need to care about it.
After set-up the Region code, System Micom will store the information of the region code to EEPROM automatically.
Initialization and Upgrade
DVD flash Initialization and Update -  Checking out MICOM & MPEG flash Version
1. Select the Setup-Support-Product information to check the Program version on the screen and front VFD display
DVD flash Initialization & Update (firmware)
1. Prepare USB that contains SSP file(Micom) and ROM file(MPEG) for Update.
2. Select the folder which has update file, then “Updating” will appear on the screen.
After completing the update, the power will go out and on, then tray will open automatically.
3. Make the unit “NO DISC” state if there is a disc and then close the tray.
4. Press “STOP” button of Main Unit 5 seconds more, display indicator shows “INITIALIZE” then power go out.
5. Initialization complete.
SMPS and amplifier schematics
Measures to be taken when the Protection Circuit operates
Operation of Power Block Protection Circuit
The Condition of Power Protection Active.
1. Voltage of SMPS’s PVDD (+22.5V, CON2) is higher or lower than Standards.
Normal Condition Voltage Range: PVDD (+22.5V, CON2): about 22.5V
2. Over-current occurs to AMP IC. (Over-output or Output short)
3. AMP IC’s temperature exceed 150°C
4. No supply voltage on GATE DRIVER
AMP Power Stage TAS5342

1. OTW: Active, IC’s inner temperature exceeds over 150°C.
(Under 2.7V, Protection Circuit wills Active)
2. SD: Shout down.
(Under 2.7V, Protection Circuit wills Active)