Monday, February 17, 2014

PHILIPS 107S2 CM2300 – 17 INCH AUTO-SCAN COLOR MONITOR - POWER SUPPLY [SMPS] SCHEMATIC [Circuit Diagram] - DISASSEMBLE PROCEDURE


SMPS SCHEMATIC
DISASSEMBLY
Rear Cover Removal
Remove right and left lib on the back cover
Open 4 lids with "-" type screwdriver.
Remove 4 screws at the bottom cabinet with "+" type screwdriver,
Remove out back cover.
Video Panel Removal
Cutoff all wire cable ties
Remove GRD wire between video shield and CRT rack.
Remove 1 screw between mains board rack and video shield
cutoff 1 cable tie on LOT wire
Remove GRD wire (1604)from video PCB to CRT rack.
Main Panel Removal
Disconnect the degaussing coil (1113) from Main panel.
Remove the video panel from CRT.
Remove the "screw" of I/F cable from Main panel.
Disconnect the CRT ground "M312" from Video panel.
Disconnect the Hi-Pot cap from CRT.
Disconnect yoke wire from "M401".
Disconnect concellation connector(1402).
Slide the main panel out of bottom tray.
Connect yoke wire to "M401".
Connect concellation connector(1402).".
Place Main panel in service position as shown in Fig.1.
Mount Video panel again on CRT.
To connect Hi-Pot cap again.
To connect "M312" again.
CLICK ON THE PICTURES TO MAGNIFY