Wednesday, May 20, 2015

SAMSUNG PEBBLE 2032BW 2232BW TFT-LCD MONITOR – SERVICE MODE – FIRMWARE UPDATE

TFT-LCD MONITOR _ SAMSUNG 2032BW - 2232BW - SERVICE MODE - DDC EXECUTE - EXPLODED VIEW
SERVICE MODE
> Set both the brightness and contrast to 0.
> Hold down the <Button>(Enter, Source) button for five (5) seconds.
> The SVC Function OSD will appear.
>
To exit the SVC Function OSD, you have to turn off the power.
The SVC Function OSD consists of a 29 (width) X 12 (height) grid.
The SVC Function OSD shows the information, software version and Micom checksum.
Service Mode (Moving around) Each time the + button is pressed, menu is selected. Then, you can adjust sub menu with – button.
Service Mode [When replacing the panel]
After replacing the panel, select the Panel item and then hold down the Menu button for five (5) seconds.
The Ch. No. of the panel will increase by one (1) and the time information will change to 0.
* HDCP Hotplug : used when HDCP Video contents are not displayed. In case that monitor is connected to some bad device which does not comply with standard.
* HotPlug Time : If Hotplug is turn on, when monitor power off/on or changing to the DVI, hotplug pin goes to the low. This function controls this time duration.
Though Hotplug is turn on monitor can’t displayed, adjust this time duration
Default is 9 (means 0.9 sec), can control 5 to 50.
HOW TO EXECUTE DDC
> Click the Open icon
> Select Two EDID
> Select a DDC file.
> Select week
> Click Next (OK).
> Enter the serial number and press the Enter key.
> After entering the analog data, repeat the procedure above 2 to 5 times to enter digital data.
TO EXECUTE MCU CODE
Options Checking.
Manufacture : MSTAR
* Device Type:TSUM16_ROM128K_ext_flash
* Communication Port: DSUB15 (Analog)
* External Memory: PMC25LV010E
* After click the ‘LoadFile’ button , choose MCU code.
‘‘Auto Program’ button choice.
 After the Program and Verify completed, execute hard power off/on.
EXPLODED