TELEFUNKEN TK3429STX – CRT TV Service Mode – Adjustments - Circuit Diagram

Used ICs: 24C08 – TMPA8829 – 4052 – MSP34X5G – TDA8944 – TDA8945 – TDA8177 – TDA16846 – TC90A49P - Telefunken TK 3429STX
  If you are unable to restore normal operation by following the detailed procedure in your operating instructions, do not attempt any further adjustment. Unplug the set and call your dealer or service technician.
  Whenever the television set is damaged or fails, or a distinct change in performance indicates a need for service, unplug the set and have it checked by a professional service technician.
  It is normal for some TV sets to make occasional snapping or popping sounds, particularly when being turned on or off. If the snapping or popping is continuous or frequent, unplug the set and consult your dealer or service technician.
Enter Factory Mode [Service Mode]
Simply press the “SERVICE” key on the factory remote handset.
Press“ 1,2,3,4,5,6,7,8,9,0,NOTEBOOK,CAPS, DISPLAY ,SLEEP, CALENDAR ,COLOR/INS, FAVORITE,RECALL”, you can switch in the sub-menus of “ FAC01
FAC18” in turns.
Press “ P+ P-”to choose the items.
Press“ V+ V-”to adjust the data.
Press OK and P+ P- to switch in the sub-menus of “ FAC19
FAC23” .
To Exit Factory Mode
Press the “SERVICE” key on the factory remote handset. All changes in factory data will be saved in EEPROM automatically.
Schematic [Circuit Diagram] & PWB
Service mode adjustments
Aging Mode = Be used for aging before adjustment in Factory Mode.
Vertical doesn’t Work = Be used for Screen & Focus voltage adjustment. In Factory Mode, press  TV/AV to enter and exit.
White balance adjustment Mode = Be used for White balance adjustment. In Factory Mode, press BUS OFF to enter and exit.
Default Value OK mode = Be used for default value setting before TV leaves Factory. In Factory Mode, press “S. EFFECT” to enter default value.  “Wait” will be displayed in screen, when it is finished, “OK” will be displayed. It will exit factory mode automatically.
Note: Now press “SERVICE” cannot enter factory mode, you have to take the following steps to enter:
1. Setting Volume to Zero.
2. Press “V-” in cabinet and Press “Display” in RC simultaneously.
BAdjustment
Apply Philips Test pattern signal in normal status, adjusting VR821 to make B+=130V±0.5V.
RF AGC adjustment
Observe monitor the collector waveform of Q101 with the probe of Oscilloscope. Select channel 2 (>70dB) from the antenna input. Enter D-mode, select menu6 to adjust
RFAGC item until the monitor peak value to 0.8Vp-p.
Sound Amplifier Adjustment
1) Apply 45.75 IF signal which is >60dB from P1101
2) Adjusting T1101 to make the voltage of Pin 15 in IC1101 is 2.5+0.05V.
Screen & Focus voltage adjustment
1) Apply pattern signal in normal status, enter D-mode, press “TV/AV” button to turn off the vertical output. (Note: The default value of RC/GC/BC is 80, and GD/BD is 40)
2) Adjust the SCRREEN switch on the flyback transformer to make a horizontal shining line just visible on the screen.
3) Turn on the vertical output, adjust the “FOCUS” on the flyback transformer to obtain the optimum focus.
White balance adjustment (NORMAL)
1) Apply Black and White Signal in normal status, enter into Factory Mode and select Menu 1.
2) Using analyzer to test the black signal part, adjust RCUT, GCUT, BCUT to make X=284, Y=299.
3) Using analyzer to test the white signal part, adjust BDRV, GDRV to make X=284, Y=299.
4) Adjusting Brightness and Contrast from Min to Max, repeat step 2)~3) to make X=284, Y=299.
Note: M134 chassis can adjust white balance automatically. In factory mode, press “I2C BUS” to enter in.
The white balance in the other two colors temperature is Warm (296, 296), Cool (279, 265).
Sub-brightness Adjustment 
1) Apply the Grey-scale/Color bar (NTSC signal) to the AV input, in normal status.
2) Enter into Factory Mode and select Menu 5, select BRTC to adjust the sub-brightness, until that the 2nd dark bar of 8 level Grey scale just can be seen.
Picture geometry adjustment
1) Apply the Philips standard testing pattern in normal status, then enter menu 3, adjusting the following data to get the min-distortion.
HPOS5/6( Horizontal Center) PARA5/6 ( Level) TRAP 5/6 (Trapezia)
HSIZE5/6 ( Horizontal Size (CNRT5/6 ( Top) CNRB5/6 ( Bottom)
2) Apply the Philips standard testing pattern in normal status, then enter menu 3, adjusting the following data to get the min-distortion.
HIGH 5/6 (Height) VP 50/60 (Vertical Center)
VLIN 5/6 (Linearity) VSC 5/6 Vertical-S Correction)
BTSC/SAP Function checking
It needn’t to adjust the BTSC/SAP, but you have to check where it does work.
CCD and V-CHIP function checking:  See the user manual for details about V-Chip function.