Minimum RMS Output Power; 8Ω, 20Hz to 20kHz, 0.019% THD: 60W+60W
Maximum Output Power (EIAJ): 1kHz, 10% THD: 6Ω 110W
Dynamic Power (IHF): 8/6/4/2Ω: 100/120/140/150W
DIN Standard Output Power: 4Ω, 1kHz, 0.7% THD: 95W
IEC Output Power: 8Ω, 1kHz, 0.019% THD: 75W
Weight: 8.7 kg (19lbs 3oz)
Remote control model number: RAX9 V499920
Do not change the IMPEDANCE SELECTOR switch setting at the back of this set, while the power to this unit is on, otherwise this unit may be damaged.
Maximum Output Power (EIAJ): 1kHz, 10% THD: 6Ω 110W
Dynamic Power (IHF): 8/6/4/2Ω: 100/120/140/150W
DIN Standard Output Power: 4Ω, 1kHz, 0.7% THD: 95W
IEC Output Power: 8Ω, 1kHz, 0.019% THD: 75W
Weight: 8.7 kg (19lbs 3oz)
Remote control model number: RAX9 V499920
Do not change the IMPEDANCE SELECTOR switch setting at the back of this set, while the power to this unit is on, otherwise this unit may be damaged.
Disassembly
(Remove parts in the order as numbered.)
1. Removal of Top Cover
Remove 4 screws (1) and 4 screws (2) in Fig.
2. Removal of Front Panel
a. Remove 6 screws (3) in Fig.
3. Checking and Parts Replacement of
MAIN P.C.B. (1)
a. Disconnect the power cord from the AC outlet.
b. Remove 3 screws (4) attaching the Speaker terminal and Impedance Selector in Fig.
a. Disconnect the power cord from the AC outlet.
b. Remove 3 screws (4) attaching the Speaker terminal and Impedance Selector in Fig.
c. Remove 2 screws (5) and remove 1 plastic rivet (6) in Fig.
then remove the Sub Chassis.
d. Remove 4 screws (7) in Fig. then remove the MAIN P.C.B. (1) with Heat Sink and Chassis.
d. Remove 4 screws (7) in Fig. then remove the MAIN P.C.B. (1) with Heat Sink and Chassis.
Adjustments: Confirmation of Idling Current
> Right after Power is switched ON, confirm the voltages measures at R553 (L ch) and R561 (R ch) are between 0.1mV to 10mV.
> If it exceeds 10mV, open (cut off) R552 (L ch), R560 (R ch) and reconfirm the voltage.
PWB and Schematic
Click on the pictures to magnify