WIRING
TROUBLESHOOTING
THERMAL PROTECTOR REMOVAL
1. Unplug the power
cord, remove the outer cabinet and discharge the capacitor.
2. Disconnect the
connectors from the thermal protector terminals.
3. Remove the
thermal protector mounting screw.
4. Remove the
thermal protector.
5. Reverse procedure
to replace.
MAGNETRON ASSEMBLY REMOVAL
1. Unplug the power
cord, remove the cabinet and discharge the capacitor.
2. Remove the front
and rear air guides and thermal protector from the magnetron.
3. Remove the four-magnetron
mounting screws from the side of oven cavity.
4. Disconnect wire
leads from magnetron and replace on new magnetron, wire for wire.
5. Reverse the above
procedure to reinstall new magnetron and reassemble.
NOTE: DO NOT LOSE SCREWS, THEY ARE M4 METRIC.
IMPORTANT: DO NOT OPERATE THE OVEN WITH THE MAGNETRON
DISASSEMBLED FROM THE WAVE-GUIDE
Thermal Protector