Haier BH-2004D CTV - How to enter service mode - Memory IC replacement_ Default Data Values _ Full Circuit Diagram.
MEMORY IC REPALCEMENT and SERVICE MODE ENTRY
* Standby off. Switch the power off and unplug the power
cord from AC outlet.
* Replace the IC. Be sure to use memory IC written with the
initial data values.
* Standby on. Plug the power cord into the AC outlet and switch
the power on.
* Check and set the System Default
Value:
* Press “Mute” “Call” “-\--“ “Call”
“Mute” buttons in sequence to enter into factory mode [Service Mode].
If the memory IC haven’t been
written with the initial data, press “Program+” / “Program –“ to select the
item “Init” and press “Volume +” / “Volume –“ to start initialize the memory IC
Check the setting value of the
System default value. If the value is
different, select items by “Pr+ / Pr—“ keys and set value by Vol + / Vol –
keys.
Press Exit button to return to
normal screen.
FACTORY SET VALUES [DEFAULT DATA VALUES TO MEMORY IC]
SCHEMATIC DIAGRAM -Full
CLICK ON THE PICTURES TO ZOOM IN