SYLVANIA LCT6637 - SERVICE MODE - SMPS and BACK-LIGHT INVERTER SCHEMATIC

Service Mode_Flicker Adjustment _ Initialization _ SMPS & Back-light Inverter Circuit Diagram. Used ICsOZ9938GN-B-O-T2 (Back-light inverter control) – ba10324af-e2 (Comparator) – UCC28600DR (Switching Control) – 2SK3568 (Switching output FET)
SERVICE MODE
* Use the service remote control unit.
* Turn the power on. (Use main power on the TV unit.)
* Press [SLEEP] button on the service remote control unit. The following screen appears.
To cancel the service mode, press [TV POWER] button on the remote control.
HOW TO MAKE A SERVICE REMOTE CONTROL FROM  normal remote control unit. (Part No. N0105UD or N0127UD) 
* Remove 3 Screws from the back lid.
* Add J1 (Jumper Wire) to the remote control CBA
FLICKER ADJUSTMENT
This adjustment is required when repairing T-CON CBA.
1. Enter the Service mode.
2. Press [2] button on the remote control unit. The following screen appears.
If Flicker Adjustment is not fit, the screen become the following [See the bottom picture]
Turn the VR1 on the LCD Module so that flash stops.
HOW TO INITILAIZE
1 To turn the power on, press [POWER] button on the normal remote control unit or the unit.
2 Use the service remote control unit
3 To enter the service mode, press [SLEEP] button on the service remote control unit.
 To cancel the service mode, press [TV POWER] button on the remote control.
4 To initialize the LCD television, press [DISPLAY] button on the normal remote control unit.
 “INITIALIZED” (red) appears on the screen.
 After few seconds (completion initialization), the screen is reset.
SMPS (Power) & BACK-LIGHT INVERTER SCHEMATICS
CLICK ON THE PICTURES TO MAGNIFY