Wednesday, January 27, 2016

Technics SUX 933 – Digital Integrated Amplifier – Circuit Diagram

Power output => 2 x 50W to 8 Ohms
POWER CONSUMPTION
For Great Britain and New Zealand => AC 50Hz/60Hz, 240V
For continental Europe => AC50Hz/60Hz, 220V
For others => Ac50Hz/60Hz, 110V/127V/240V
The protection circuitry may have operated if either of the following conditions are noticed:
* No sound is heard when the power is switched ON.
* Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage, if for example, the positive and negative speaker connection wires are SHORTED, 
or if the speaker systems with an impedance less than the indicted rated impedance of this unit are used.
If this occurs, follow:
# Switch OFF the power.
# Determine the cause of the problem and correct it.
# Switch ON the power once again.
[When the protection circuitry functions, the unit will not operate unless the power is first switched OFF and then ON again.]
BEFORE REPAIR
Turn off the power supply.  Using a 10 Ohms, 5W resistor connect both ends of the power supply capacitors [C711, C712, 3300Uf] in order to discharge the voltage.
Before turning on the power supply, after completion of repair, slowly apply the primary voltage by using a power supply voltage controller to make sure that the consumed current at 50Hz/60Hz in NO SIGNAL mode should be shown with respect to supply voltage 110/127, 220/240.
SCHEMATIC [Circuit diagram] Full
Circuit Daigram - Split
Wiring (External)
CLICK ON THE PICTURES TO MAGNIFY