SANYO VIZON - DP-42545 _ TROUBLESHOOTING CHART - SERVICE MODE - LED BLINKS



TROUBLESHOOTING
NO POWER  [Click on the charts to zoom in]
NO AUDIO
CLICK ON THE PICTURES TO ZOOM IN
NO VIDEO
SERVICE MODE
  • While pressing the Volume (-) button on the TV, press the Number Key (1) on the remote control unit. The service menu screen shown as below will be displayed.
  • Press Menu UP/DN key to select the desired service menu.
  • Press channel Up/Dn key to skip up or down 10 items.
  • Use Menu Right/Left key to adjust the data.
  • Press Menu key to Exit service mode.
POWER FAILURE CIRCUIT
Power failure 1: (Normal: High, Failure: Low).  Detected voltage failure for analog circuit [Connected to IC801 pin 52]
Power failure 2: (Normal: Low, Failure: High). Detected voltage failure for audio AMPP IC. [Connected to IC801 pin 53]
Power failure 3: (Normal: High, Failure: Low). Detected voltage failure for digital circuit. [Connected to IC801 pin 54]

Temperature Failure : (Normal: Low, Failure: High)  Detected temperature failure for Main Power Unit  [Connected to IC801 pin 57]
LED Flashing
When IC801 detects the Power Failure the LED will flash to indicate a power failure has occurred.  The type of failure detected as shown below will determine the number of flashes.  If power failure is detected 3 times, the set will enter the standby mode, and cannot be switched ON.  To reset the operating programs of the CPU, it is necessary to disconnect the AC cord for a short time.  When finishing the repair or stopping the Power Failure, the history of past failures can be checked.
TO SEE THE HISTORY
Enter service mode.
Select item number [355] POWER ERROR from the service adjustment data table.
If simultaneous failures have been detected, the sum of each data is displayed.  For example:
Power failures 1&2
01h + 10h = 11h (17)