SERVICE MODE
[OPTION 1]
Disconnect AC, and Push front panel key
([OPEN/CLOSE] + [PLAY] + [STOP]) and AC IN
The keys will be released if the screen in service mode is
displayed on a monitor.
Control via Remote Controller
[OPTION 2]
Connect the set to AC, and wait initialization cycle
complete . POWER ON SET INTO NORMAL MODE. WHEN CROSS MEDIA BAR APPEAR.
Use Sony BDP remote controller, key in the following SIRCS
code. [DISPLAY] à [ 0 ] à [ 2 ] à [ 1 ] à [SUBTITLE]
While sending of SIRCS code, wait time between each key code
could not send later then 3 second.
If 3 second waiting is exceeded user have to re-key in the
SIRCS code.
If SIRCS enter is successful, set will auto boot up. The
screen of service mode is displayed on a monitor.
Control via Remote Controller
Diag: The unit test of the device mounted on the Main Board.
Display Error Log: Error log is displayed. The displayed logs can be saved in a USB
memory.
Factory Initialize: Return all of the player setting to
their factory defaults.
Network: Confirm Wired Network connection.
Version Up: The set updates by Update DISC.
System Information: System information of the set is
displayed. The Information on a soft version and drive information, etc. is
displayed.
EMC Test Mode: Not used.
Drive: Write Drive OP Data and check drive.
HDD Mode: Not used
CLICK ON THE CHART TO ZOOM IN