- The power must be supplied normally to the PDP unit. This power is supplied through two black 8-pin connectors from the power unit. The kinds of power supply are 160 V line, 60 V line, and 5 V line.
- As input signals, H.SYNC (negative polarity), V.SYNC (negative polarity), BLANKING (negative polarity), CLOCK and RGB digital data (8 bit x3) must be entered normally and DISPEN must be “high”.
- If no images appears through the above conditions are satisfied, the PDP unit will be defective.