Test Equipment: CA-210
Using LCD color temperature, Color Analyzer (CA-210) must
use CH 9, which Matrix compensated (White, Red, Green, Blue compensation) with
CS-2100. See the Coordination bellow.
Manual adjustment sequence is
- Turn to "Ez-Adjust" mode with press ADJ button of service remocon.
- Select "10.Test Pattern" with CH+/- button and press enter. Then set will go on Heat-run mode. Over 30 minutes set let on Heat-run mode.
- Let CA-210 to zero calibration and must has gap more 10cm from center of LCD module when adjustment.
- Press "ADJ" button of service remocon and select "7.White-Balance" in "Ez-Adjust" then press "Ü" button of navigation key. (When press "Ü" button then set will go to full white mode)
- If "cool" mode ; Let B-Gain to 192 and R, G, B-Cut to 64 and then control R, G gain adjustment High Light adjustment.
- If "Medium" and "Warm" mode; Let R-Gain to 192 and R, G, B-Cut to 64 and then control G, B gain adjustment High Light adjustment.
- All of the three mode; Let R-Gain to 192 and R, G, B-Cut to 64 and then control G, B gain adjustment High Light adjustment. [With volume button (+/-) you can adjust.]
- After all adjustment finished, with Enter (Ykey) turn to Ez-Adjust mode. Then with ADJ button, exit from adjustment mode.
Using CS-1000 Equipment.
COOL : T=11000K, ¦uv=0.000, x=0.276 y=0.283
MEDIUM : T=9300K, ¦uv=0.000, x=0.285 y=0.293
WARM : T=6500K, ¦uv=0.000, x=0.313 y=0.329
EYE-Q Function checks.
- Turn on TV
- Press EYE Key of Adj R/C
- Cover the Eye Q II sensor on the front of the using your hand and wait for 6 seconds
- Confirm that R/G/B value is not lower than 10 of the ‘Raw Data (Sensor data, Back light)”. If after 6 seconds, R/G/B value is not lower than 10, replace EYE Q II sensor.
- Remove your hand from the EYE Q II sensor and wait for 6 second
- Confirm that “OK” pop up. If change is not seen, replace EYE Q II sensor.
Selection of Country option.
Selection of country option is allowed only North American
model (Not allowed Korean model). It is
selection of Country about Rating and Time Zone.
Models: All models, which use LA75A Chassis.
- Press “In-Start” button of Service Remocon, then enter the “Option” Menu with “PIP CH-“Button.
- Select one of these three (USA, CANADA, MEXICO) defends on its market using “Vol. +/-“button.