POWER SUPPLY [SMPS] BOARD
MAIN PWB TO SMPS P-201 TURN-ON CIRCUIT
CLICK ON THE PICTURES TO MAGNIFY
POWER SUPPLY PWB _ LOW-VOLTAGE TEST
AC Should not be applied at any time while adding resistors or while unplugging
connectors as damage tothe circuit PWB may occur.
a) The SMPS PWB “MUST” be producing STBY 5V on all of the pins 7, 8, 9
or 10 (5V). If 5V Standby is not being
generated, the SMPS PWB is defective and must be replaced. There is no need to
continue with the next test.
(b) Unplug P2400 on the Main PWB.
TEST 1:
(1) Add a 100Ωresistor between (5V STBY) pin 7, 8, 9 or 10 and Pin 2 (PWR).
Apply AC. This will turn on the power supply.
a) Check that the 24V and 12V power supplies are turned on,
• P201 (24V pins 17 and 18)
• P201 (12V pins 13 and 14)
(2) Remove AC power.
POWER SUPPLY PWB _ BACK-LIGHTS TEST
P2400 Connector disconnected from the MainPWB. Apply AC after adding
jumper.
Continue if the 1st test was OK. Leave original resistor in
place.
(3) Add another 100Ωresistor between (5V) pin 7, 8, 9 or 10 and Pin 20
(INV On).
(4) Apply AC Power. Simulating a Power and Backlight On command.
Backlights Normal:
a) If normal, the backlights should turn on. SMPS OK.
Backlights Abnormal:
a) Recheck all connections.
b) Confirm the INV On/Off line pulling up to at least 3V.
REMOVE AC POWER:
c) Check the connections to the Backlights.
DO NOT check these when AC is applied as they carry 1200V each.
Note, either of the connections are unplugged, the backlights will not light.