How to enter Service Mode_Hotel Mode_Self Check Mode_Power LED blinking codes_Voltage Chart to A & P boards. Panasonic TC L32E5
Service Mode
While pressing [VOLUME ( - )] button of
the main unit, press [INFO] button of the remote control three times within 2
seconds.Service Mode
Contents of
adjustment mode
Value is shown as a hexadecimal number.
Preset value differs depending on models.
After entering the adjustment mode, take note of the value in each item before starting adjustment.
Value is shown as a hexadecimal number.
Preset value differs depending on models.
After entering the adjustment mode, take note of the value in each item before starting adjustment.
How to exit
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
SRV-TOOL [How
to access]
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
Display of
SOS History
SOS History (Number of LED blinking ) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory shipment setting].
SOS History (Number of LED blinking ) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory shipment setting].
POWER ON
TIME/COUNT
Note : To display TIME/COUNT menu, highlight position, then press MUTE for 3sec.
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
Note : To display TIME/COUNT menu, highlight position, then press MUTE for 3sec.
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
Exit
Disconnect the AC cord from wall outlet.
Disconnect the AC cord from wall outlet.
Self Check
Mode
1. Press the ‘MENU’ button (on the remote control) and the ‘VOL DOWN’ button on the LCD panel.
2. Press ON/OFF button on the panel to Exit.
1. Press the ‘MENU’ button (on the remote control) and the ‘VOL DOWN’ button on the LCD panel.
2. Press ON/OFF button on the panel to Exit.
Hotel Mode
Adjustment
1. Press the ‘VOLUME DOWN’ button on the TV panel and simultaneously press the INPUT button on the remote control 3 times to enter Hotel Mode.
2. Set Hotel mode ‘on/off’, then press ‘EXIT’ to come out.
1. Press the ‘VOLUME DOWN’ button on the TV panel and simultaneously press the INPUT button on the remote control 3 times to enter Hotel Mode.
2. Set Hotel mode ‘on/off’, then press ‘EXIT’ to come out.
Hotel Mode [ Purpose]
Restrict a function for hotels.
Access command to the Hotel mode setup menu.
In order to display the Hotel mode setup menu, enter the following command (within 2 second). [TV] : Vol [Down] + [REMOTE] : INPUT (3 times).
Restrict a function for hotels.
Access command to the Hotel mode setup menu.
In order to display the Hotel mode setup menu, enter the following command (within 2 second). [TV] : Vol [Down] + [REMOTE] : INPUT (3 times).
To exit the Hotel mode setup menu: Disconnect
AC power cord from wall outlet.
Explain the Hotel mode setup menu.
Explain the Hotel mode setup menu.
Check of the
IIC bus lines
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote control for more than 3 seconds.
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote control for more than 3 seconds.
Exit
Disconnect the AC cord from wall outlet.
Disconnect the AC cord from wall outlet.
Power LED
blinking timing chart
When an abnormality occurs, the
protection circuit will operate and reset the unit to stand by mode. During
this time, the defective block can be identified by the number of blinking
times of the Power LED on the front panel of the unit as follow:
Voltage chart
of A-board
Set A-Board to a dummy set and check the satisfaction with the specified voltage as following table.
Set A-Board to a dummy set and check the satisfaction with the specified voltage as following table.
Voltage chart
of P-board
Set P-Board to a dummy set and check the satisfaction with the specified voltage as following table.
Set P-Board to a dummy set and check the satisfaction with the specified voltage as following table.
Click on the Tables to Magnify