TEST MODE
EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard procedures must be followed.
In standby mode, press [TOP MENU], [CLEAR], [POWER] to enter Remocon Diagnosis Mode.
Select “2. Drive Manual Operation” by pressing the 2 key on the remote commander.
Select “3. Manual Adjustment” by pressing the 3 key on the remote commander.
Select Iop by pressing 6 key on the remote commander.
Wait until a hexadecimal number appear.
Convert data from hexadecimal to decimal.
Use the following formula to calculate IOP in mA IOP (mA) = IOP (decimal) x 0.622678.
Press [RETURN] to return back to previous menu.
Press - to return to Top Menu and power OFF the DVD Player.
EMERGENCY HISTORY CHECK
Information of Emergency History.
In standby mode, press [TOP MENU], [CLEAR], [POWER] to enter Remocon Diagnosis Mode.
Select “3. Emergency History”
[[Next] Next Page [Prev] Prev Page]
Laser Hours
DVD Laser ON time. (Total ON time) CD Laser ON time. (Total ON time)
Emergency History
The history information from last “1” to “10” can be scrolled with [NEXT] key or [PREV] key.
Error code list
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mecha move error (5 Changer)
26: Mecha move stack error
30: DC Motor adjustment error
31: DPD offset adjustment error
32: TE Balance adjustment error
33. TE Sensor adjustment error
34. TE loop gain adjustment error
35. FE loop gain adjustment error
36. Bad jitter after adjustment
40. Focus NG
42. Focus Layer Jump NG
52. Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: read Qdata/ID error
70: Lead In Data Read Fail
71: TOC read time out (CD)
80: Can’t Buffering
81: Unknown media type
Error code parameters
This is the detailed contents of error information - Laser hours at error happened.
How to CLEAR laser hours
Press [DISPLAY], [CLEAR] keys in this order.
Both CD and DVD data are cleared.
How to Clearing Emergency code
Press [TOPMENU], [CLEAR] keys in this order.
All emergency code is cleared.
Press [0] key, return to TOP MENU.
INITIALIZING SETUP DATA
How to initializing setup data.
(1) In standby mode, press [TOP MENU], [CLEAR], [POWER] to enter Remocon Diagnosis Mode.
(2) Select “3. Emergency History”.
(3) Initializing setup data
Press [MENU], [CLEAR] keys in this order.
The data have been initialized when “Initialize setup data...” mesage is displayed.
(4) The Emergency history display screen will be restored soon.
Press [0] key, return to TOP MENU.
SMPS circuit diagram
VERSION INFORMATION
(1) In standby mode, press [TOP MENU], [CLEAR], [POWER] to enter Remocon Diagnosis Mode.
(2) Select “4. Version Information”.
(3) Press[0] key, return to TOP MENU.
IF CON SELF DIAGNOSTIC FUNCTION
IF-124 BOARD (IF CON) TEXT MODE
The IF-124 board (IF CON) test mode is the IF CON self-diagnosis mode. The IF CON can diagnose the functions of the IF-124 board that the IF CON controls. Normally, the IF CON makes a serial communication with the SYSTEM CONTROL and operates following the commands from the SYSTEM CONTROL, but in the Test mode, the IF CON operates independently from the SYSTEM CONTROL.
In the test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Fluorescent display tube lighting check
- Grid check
- Anode check
5. LED control function.
In the test mode, the main unit operates same as usual, except voltage monitoring, communication, display of fluorescent display tube, and LED control.
1. The routine that monitors +3.3V (PCONT) of MV-045 board is not provided.
2. The monitoring timer for serial communication with the SYSTEM CONTROL is not provided. The main unit is not placed in the Standby mode, even if the communication with SYSTEM CONTROL is normal.
3. Display of fluorescent display tube.  (Normally, display is mode following the commands from SYSTEM CONTROL).
4. LED control. (Normally, control is mode made following the commands from SYSTEM CONTROL).
OPERATION OF SELF CHECK MODE
The Self Check mode is the function to conduct the basic test to the FL display and DVD panel section.
Self Check Mode Transition Processing
At the AC Power ON after reset of IF CON is released, while pressing with the MV-045 board are not connected to the IF-124 board, or while pressing the STOP key on the main unit with the IF CON in STANDBY mode, enter [RETURN] => [DISPLAY] (or [SETUP]) on the remote commander, and the main unit transits to the Self Check Mode.
Operation of Auto Self Check
When the Self Check mode becomes active at the AC Power ON or by key input, the test display of the following steps (1) to (4) is repeated.
(1) FLD and LED all ON (for 10 seconds)
(2) MODEL display (for 1 seconds) (NS41P/NS50P) [MODEL display (for 1 seconds) (NS52P only)]
(3) Version display (for 1 seconds)
(4) ROM creation date display (for 1 seconds)
Transition Keys in Self Check Mode 
Keys on the main unit except keys transited in Self Check Mode.
Operation and Display
When a key on the main unit is pressed in the Self Check mode, the name of that key is displayed on the FLD. Aslo, the key name display and the key code display can be switched with the [DISPLAY] key on the remote commander, “NOTHING” is displayed when nothing is entered. Also, DVD, V, CD segments turn on when a communication error occurred.