TFT-LCD MONITOR SAMSUNG 713N 711N 721N _Service Mode and Adjustment
procedure
How to Display Service Function OSD
1. The value for brightness and contrast should be changed to zero.
2. Within 5 seconds, press the (Enter/Source) key.
3. Service function OSD will be displayed.
To disable [Exit] the service function OSD; power off the unit.
1. The value for brightness and contrast should be changed to zero.
2. Within 5 seconds, press the (Enter/Source) key.
3. Service function OSD will be displayed.
To disable [Exit] the service function OSD; power off the unit.
The service function OSD is based on a grid of 29 columns x 12
rows.
The service function OSD consists of panel information, software version and MICOM checksum.
The service function OSD consists of panel information, software version and MICOM checksum.
To Control Service Function OSD
With the panel selected on OSD, whenever you press the right key, the base
color will change to blue from “Panel” to “Upper Lamp”, “Lower Lamp”.
The case of panel change
After changing the panel, press the menu key within 5 seconds, then, panel Ch. No increases one step and the panel time information is reset to zero.
Simultaneously, other information is reset to zero (Upper/Lower lamp, Panel cycle).
After changing the panel, press the menu key within 5 seconds, then, panel Ch. No increases one step and the panel time information is reset to zero.
Simultaneously, other information is reset to zero (Upper/Lower lamp, Panel cycle).
In the case of Upper Lamp or Lower Lamp change
After changing the Upper Lamp or Lower Lamp,
1. Select the Upper Lamp or Lower Lamp
2. Press the Menu key within an 5 seconds.
Then, Ch. No and time will be reset to zero (selected item only).
After changing the Upper Lamp or Lower Lamp,
1. Select the Upper Lamp or Lower Lamp
2. Press the Menu key within an 5 seconds.